Breast imaging reporting and data system (BI-RADS™): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS™): how is it being used?

O Breast Imaging Reporting and Data System (BI-RADS™), do American College of hRadiology, foi concebido para padronizar o laudo mamográfico e reduzir os fatores de confusão na descrição e interpretação das imagens, além de facilitar o monitoramento do resultado final. OBJETIVO: Identificar...

Full description

Bibliographic Details
Main Authors: Eduardo Rodrigues Godinho, Hilton Augusto Koch
Format: Article
Language:English
Published: Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2004-12-01
Series:Radiologia Brasileira
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842004000600006
id doaj-75c299961e544474b41f736b43f9f66b
record_format Article
spelling doaj-75c299961e544474b41f736b43f9f66b2020-11-24T22:51:45ZengColégio Brasileiro de Radiologia e Diagnóstico por ImagemRadiologia Brasileira0100-39841678-70992004-12-0137641341710.1590/S0100-39842004000600006Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?Eduardo Rodrigues GodinhoHilton Augusto KochO Breast Imaging Reporting and Data System (BI-RADS&trade;), do American College of hRadiology, foi concebido para padronizar o laudo mamográfico e reduzir os fatores de confusão na descrição e interpretação das imagens, além de facilitar o monitoramento do resultado final. OBJETIVO: Identificar a maneira como vem sendo utilizado o BI-RADS&trade;, gerando informações que possam auxiliar o Colégio Brasileiro de Radiologia a desenvolver estratégias para aperfeiçoar o seu uso. MATERIAIS E MÉTODOS: Os dados foram coletados na cidade de Goiânia, GO. Foram solicitados os exames de mamografia anteriores a todas as mulheres que se dirigiram ao serviço para realização de mamografia entre janeiro/2003 e junho/2003. Foram incluídos na análise exames anteriores, realizados entre 1/7/2001 e 30/6/2003. RESULTADOS: Foram coletados 104 laudos anteriores, emitidos por 40 radiologistas de 33 diferentes serviços. Dos 104 laudos, 77% (n = 80) utilizavam o BI-RADS&trade;. Destes, apenas 15% (n = 12) eram concisos, nenhum utilizava a estrutura e organização recomendadas pelo sistema, 98,75% (n = 79) não respeitavam o léxico e 65% (n = 51) não faziam recomendação de conduta. CONCLUSÃO: O BI-RADS&trade;, apesar de bastante utilizado, não foi reconhecido como sistema para padronização dos laudos. Foi usado quase exclusivamente como forma de classificação final dos exames.<br>The Breast Imaging Reporting and Data System (BI-RADS&trade;) from the American College of Radiology is a system designed to standardize mammographic reporting, reduce confounding factors in breast imaging interpretation, and to simplify the management of the final result. OBJECTIVE: To identify how the system is being used, providing information to help the Brazilian College of Radiology to develop strategies to improve its use. MATERIALS AND METHODS: Data were collected in the City of Goiânia, GO, Brazil. Each woman submitted to the examination in the service between January and June, 2003 was asked to provide previous reports and films. Examinations performed between 1/7/2001 and 30/6/2003 were included in the analysis. RESULTS: A total of 104 previous reports done by 40 radiologists from 33 different services were collected for analysis; 77% (n = 80) used the BI-RADS&trade;. From these, only 15% (n = 12) were concise, none followed the recommendations suggested by the system, 98.75% (n = 79) were not in conformity with the lexicon terminology and in 65% (n = 51) there was no reference to pertinent recommendations. CONCLUSION: Although largely used, BI-RADS&trade; was not recognized as a system designed to standardize the reports and it was used almost exclusively to a final categorization of the exams.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842004000600006MamografiaNeoplasias mamáriasDetecçãoMammographyBreast neoplasmsDetection
collection DOAJ
language English
format Article
sources DOAJ
author Eduardo Rodrigues Godinho
Hilton Augusto Koch
spellingShingle Eduardo Rodrigues Godinho
Hilton Augusto Koch
Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?
Radiologia Brasileira
Mamografia
Neoplasias mamárias
Detecção
Mammography
Breast neoplasms
Detection
author_facet Eduardo Rodrigues Godinho
Hilton Augusto Koch
author_sort Eduardo Rodrigues Godinho
title Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?
title_short Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?
title_full Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?
title_fullStr Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?
title_full_unstemmed Breast imaging reporting and data system (BI-RADS&trade;): como tem sido utilizado? Breast imaging reporting and data system (BI-RADS&trade;): how is it being used?
title_sort breast imaging reporting and data system (bi-rads&trade;): como tem sido utilizado? breast imaging reporting and data system (bi-rads&trade;): how is it being used?
publisher Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
series Radiologia Brasileira
issn 0100-3984
1678-7099
publishDate 2004-12-01
description O Breast Imaging Reporting and Data System (BI-RADS&trade;), do American College of hRadiology, foi concebido para padronizar o laudo mamográfico e reduzir os fatores de confusão na descrição e interpretação das imagens, além de facilitar o monitoramento do resultado final. OBJETIVO: Identificar a maneira como vem sendo utilizado o BI-RADS&trade;, gerando informações que possam auxiliar o Colégio Brasileiro de Radiologia a desenvolver estratégias para aperfeiçoar o seu uso. MATERIAIS E MÉTODOS: Os dados foram coletados na cidade de Goiânia, GO. Foram solicitados os exames de mamografia anteriores a todas as mulheres que se dirigiram ao serviço para realização de mamografia entre janeiro/2003 e junho/2003. Foram incluídos na análise exames anteriores, realizados entre 1/7/2001 e 30/6/2003. RESULTADOS: Foram coletados 104 laudos anteriores, emitidos por 40 radiologistas de 33 diferentes serviços. Dos 104 laudos, 77% (n = 80) utilizavam o BI-RADS&trade;. Destes, apenas 15% (n = 12) eram concisos, nenhum utilizava a estrutura e organização recomendadas pelo sistema, 98,75% (n = 79) não respeitavam o léxico e 65% (n = 51) não faziam recomendação de conduta. CONCLUSÃO: O BI-RADS&trade;, apesar de bastante utilizado, não foi reconhecido como sistema para padronização dos laudos. Foi usado quase exclusivamente como forma de classificação final dos exames.<br>The Breast Imaging Reporting and Data System (BI-RADS&trade;) from the American College of Radiology is a system designed to standardize mammographic reporting, reduce confounding factors in breast imaging interpretation, and to simplify the management of the final result. OBJECTIVE: To identify how the system is being used, providing information to help the Brazilian College of Radiology to develop strategies to improve its use. MATERIALS AND METHODS: Data were collected in the City of Goiânia, GO, Brazil. Each woman submitted to the examination in the service between January and June, 2003 was asked to provide previous reports and films. Examinations performed between 1/7/2001 and 30/6/2003 were included in the analysis. RESULTS: A total of 104 previous reports done by 40 radiologists from 33 different services were collected for analysis; 77% (n = 80) used the BI-RADS&trade;. From these, only 15% (n = 12) were concise, none followed the recommendations suggested by the system, 98.75% (n = 79) were not in conformity with the lexicon terminology and in 65% (n = 51) there was no reference to pertinent recommendations. CONCLUSION: Although largely used, BI-RADS&trade; was not recognized as a system designed to standardize the reports and it was used almost exclusively to a final categorization of the exams.
topic Mamografia
Neoplasias mamárias
Detecção
Mammography
Breast neoplasms
Detection
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842004000600006
work_keys_str_mv AT eduardorodriguesgodinho breastimagingreportinganddatasystembiradstradecomotemsidoutilizadobreastimagingreportinganddatasystembiradstradehowisitbeingused
AT hiltonaugustokoch breastimagingreportinganddatasystembiradstradecomotemsidoutilizadobreastimagingreportinganddatasystembiradstradehowisitbeingused
_version_ 1725668897343930368