An innovative non-invasive technique for subcutaneous tumour measurements.

INTRODUCTION:In oncological drug development, animal studies continue to play a central role in which the volume of subcutaneous tumours is monitored to assess the efficacy of new drugs. The tumour volume is estimated by taking the volume to be that of a regular spheroid with the same dimensions. Ho...

Full description

Bibliographic Details
Main Authors: Juan Delgado-SanMartin, Beate Ehrhardt, Marcin Paczkowski, Sean Hackett, Andrew Smith, Wajahat Waraich, James Klatzow, Adeala Zabair, Anna Chabokdast, Leonardo Rubio-Navarro, Amar Rahi, Zena Wilson
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0216690
id doaj-7638a866e5e14c709e95a8bca36d322f
record_format Article
spelling doaj-7638a866e5e14c709e95a8bca36d322f2021-03-03T21:06:14ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-011410e021669010.1371/journal.pone.0216690An innovative non-invasive technique for subcutaneous tumour measurements.Juan Delgado-SanMartinBeate EhrhardtMarcin PaczkowskiSean HackettAndrew SmithWajahat WaraichJames KlatzowAdeala ZabairAnna ChabokdastLeonardo Rubio-NavarroAmar RahiZena WilsonINTRODUCTION:In oncological drug development, animal studies continue to play a central role in which the volume of subcutaneous tumours is monitored to assess the efficacy of new drugs. The tumour volume is estimated by taking the volume to be that of a regular spheroid with the same dimensions. However, this method is subjective, insufficiently traceable, and is subject to error in the accuracy of volume estimates as tumours are frequently irregular. METHODS & RESULTS:This paper reviews the standard technique for tumour volume assessment, calliper measurements, by conducting a statistical review of a large dataset consisting of 2,500 tumour volume measurements from 1,600 mice by multiple operators across 6 mouse strains and 20 tumour models. Additionally, we explore the impact of six different tumour morphologies on volume estimation and the detection of treatment effects using a computational tumour growth model. Finally, we propose an alternative method to callipers for estimating volume-BioVolumeTM, a 3D scanning technique. BioVolume simultaneously captures both stereo RGB (Red, Green and Blue) images from different light sources and infrared thermal images of the tumour in under a second. It then detects the tumour region automatically and estimates the tumour volume in under a minute. Furthermore, images can be processed in parallel within the cloud and so the time required to process multiple images is similar to that required for a single image. We present data of a pre-production unit test consisting of 297 scans from over 120 mice collected by four different operators. CONCLUSION:This work demonstrates that it is possible to record tumour measurements in a rapid minimally invasive, morphology-independent way, and with less human-bias compared to callipers, whilst also improving data traceability. Furthermore, the images collected by BioVolume may be useful, for example, as a source of biomarkers for animal welfare and secondary drug toxicity / efficacy.https://doi.org/10.1371/journal.pone.0216690
collection DOAJ
language English
format Article
sources DOAJ
author Juan Delgado-SanMartin
Beate Ehrhardt
Marcin Paczkowski
Sean Hackett
Andrew Smith
Wajahat Waraich
James Klatzow
Adeala Zabair
Anna Chabokdast
Leonardo Rubio-Navarro
Amar Rahi
Zena Wilson
spellingShingle Juan Delgado-SanMartin
Beate Ehrhardt
Marcin Paczkowski
Sean Hackett
Andrew Smith
Wajahat Waraich
James Klatzow
Adeala Zabair
Anna Chabokdast
Leonardo Rubio-Navarro
Amar Rahi
Zena Wilson
An innovative non-invasive technique for subcutaneous tumour measurements.
PLoS ONE
author_facet Juan Delgado-SanMartin
Beate Ehrhardt
Marcin Paczkowski
Sean Hackett
Andrew Smith
Wajahat Waraich
James Klatzow
Adeala Zabair
Anna Chabokdast
Leonardo Rubio-Navarro
Amar Rahi
Zena Wilson
author_sort Juan Delgado-SanMartin
title An innovative non-invasive technique for subcutaneous tumour measurements.
title_short An innovative non-invasive technique for subcutaneous tumour measurements.
title_full An innovative non-invasive technique for subcutaneous tumour measurements.
title_fullStr An innovative non-invasive technique for subcutaneous tumour measurements.
title_full_unstemmed An innovative non-invasive technique for subcutaneous tumour measurements.
title_sort innovative non-invasive technique for subcutaneous tumour measurements.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2019-01-01
description INTRODUCTION:In oncological drug development, animal studies continue to play a central role in which the volume of subcutaneous tumours is monitored to assess the efficacy of new drugs. The tumour volume is estimated by taking the volume to be that of a regular spheroid with the same dimensions. However, this method is subjective, insufficiently traceable, and is subject to error in the accuracy of volume estimates as tumours are frequently irregular. METHODS & RESULTS:This paper reviews the standard technique for tumour volume assessment, calliper measurements, by conducting a statistical review of a large dataset consisting of 2,500 tumour volume measurements from 1,600 mice by multiple operators across 6 mouse strains and 20 tumour models. Additionally, we explore the impact of six different tumour morphologies on volume estimation and the detection of treatment effects using a computational tumour growth model. Finally, we propose an alternative method to callipers for estimating volume-BioVolumeTM, a 3D scanning technique. BioVolume simultaneously captures both stereo RGB (Red, Green and Blue) images from different light sources and infrared thermal images of the tumour in under a second. It then detects the tumour region automatically and estimates the tumour volume in under a minute. Furthermore, images can be processed in parallel within the cloud and so the time required to process multiple images is similar to that required for a single image. We present data of a pre-production unit test consisting of 297 scans from over 120 mice collected by four different operators. CONCLUSION:This work demonstrates that it is possible to record tumour measurements in a rapid minimally invasive, morphology-independent way, and with less human-bias compared to callipers, whilst also improving data traceability. Furthermore, the images collected by BioVolume may be useful, for example, as a source of biomarkers for animal welfare and secondary drug toxicity / efficacy.
url https://doi.org/10.1371/journal.pone.0216690
work_keys_str_mv AT juandelgadosanmartin aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT beateehrhardt aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT marcinpaczkowski aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT seanhackett aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT andrewsmith aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT wajahatwaraich aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT jamesklatzow aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT adealazabair aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT annachabokdast aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT leonardorubionavarro aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT amarrahi aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT zenawilson aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT juandelgadosanmartin innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT beateehrhardt innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT marcinpaczkowski innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT seanhackett innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT andrewsmith innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT wajahatwaraich innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT jamesklatzow innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT adealazabair innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT annachabokdast innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT leonardorubionavarro innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT amarrahi innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
AT zenawilson innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements
_version_ 1714818774726606848