Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening

Background: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective...

Full description

Bibliographic Details
Main Authors: Mehrdad Masoudifar, Reyhanak Talakoub, Payam Ebrahimifar
Format: Article
Language:fas
Published: Vesnu Publications 2012-12-01
Series:مجله دانشکده پزشکی اصفهان
Online Access:http://jims.mui.ac.ir/index.php/jims/article/view/2009
id doaj-769e25c66d3f40d7a559b7d0e662890f
record_format Article
spelling doaj-769e25c66d3f40d7a559b7d0e662890f2020-11-25T01:09:10ZfasVesnu Publications مجله دانشکده پزشکی اصفهان1027-75951735-854X2012-12-0130212181318171190Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura OpeningMehrdad Masoudifar0Reyhanak Talakoub1Payam Ebrahimifar2Assistant Professor, Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranAssociate Professor, Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranStudent of Medicine, School of Medicine AND Student Research Committee, Isfahan University of Medical Sciences, Isfahan, IranBackground: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective craniotomy patients aged 18-64 years with the American Society of Anesthesiologists (ASA) physical status I or II. After being evaluated by CT scan, ICP was studied with Schiotz tonometer in Burr hole before dura opening. Findings: 58 patients (mean age: 44.37 ± 11.53 years) scheduled for elective craniotomy were included in the study. There were 36 males (62.1%) and 22 females (37.9%). The results showed significant correlation between ICP measured by Schiotz tonometer and by CT scan (r = 0.913, P < 0.001). Conclusion: This study showed that Schiotz tonometer could consider as a safe and reliable alternative to CT scan in ICP evaluation. Keywords: Intracranial pressure, Schiotz tonometer, X-ray computed tomographyhttp://jims.mui.ac.ir/index.php/jims/article/view/2009
collection DOAJ
language fas
format Article
sources DOAJ
author Mehrdad Masoudifar
Reyhanak Talakoub
Payam Ebrahimifar
spellingShingle Mehrdad Masoudifar
Reyhanak Talakoub
Payam Ebrahimifar
Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
مجله دانشکده پزشکی اصفهان
author_facet Mehrdad Masoudifar
Reyhanak Talakoub
Payam Ebrahimifar
author_sort Mehrdad Masoudifar
title Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
title_short Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
title_full Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
title_fullStr Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
title_full_unstemmed Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
title_sort evaluation of the correlation between intracranial pressures measured by schiotz tonometer and computed tomography scan findings in craniotomy patients before dura opening
publisher Vesnu Publications
series مجله دانشکده پزشکی اصفهان
issn 1027-7595
1735-854X
publishDate 2012-12-01
description Background: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective craniotomy patients aged 18-64 years with the American Society of Anesthesiologists (ASA) physical status I or II. After being evaluated by CT scan, ICP was studied with Schiotz tonometer in Burr hole before dura opening. Findings: 58 patients (mean age: 44.37 ± 11.53 years) scheduled for elective craniotomy were included in the study. There were 36 males (62.1%) and 22 females (37.9%). The results showed significant correlation between ICP measured by Schiotz tonometer and by CT scan (r = 0.913, P < 0.001). Conclusion: This study showed that Schiotz tonometer could consider as a safe and reliable alternative to CT scan in ICP evaluation. Keywords: Intracranial pressure, Schiotz tonometer, X-ray computed tomography
url http://jims.mui.ac.ir/index.php/jims/article/view/2009
work_keys_str_mv AT mehrdadmasoudifar evaluationofthecorrelationbetweenintracranialpressuresmeasuredbyschiotztonometerandcomputedtomographyscanfindingsincraniotomypatientsbeforeduraopening
AT reyhanaktalakoub evaluationofthecorrelationbetweenintracranialpressuresmeasuredbyschiotztonometerandcomputedtomographyscanfindingsincraniotomypatientsbeforeduraopening
AT payamebrahimifar evaluationofthecorrelationbetweenintracranialpressuresmeasuredbyschiotztonometerandcomputedtomographyscanfindingsincraniotomypatientsbeforeduraopening
_version_ 1725179631793864704