Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway

Background: Difficult airway (DA) occurs frequently (5–15%) in clinical practice. The El-Ganzouri Risk Index (EGRI) has a high sensitivity for predicting a difficult intubation (DI). However difficult mask ventilation (DMV) was never included in the EGRI. Since DMV was not included in the EGRI asses...

Full description

Bibliographic Details
Main Authors: Ruggero M. Corso, Davide Cattano, Matteo Buccioli, Elisa Carretta, Stefano Maitan
Format: Article
Language:English
Published: Elsevier 2016-05-01
Series:Brazilian Journal of Anesthesiology
Online Access:http://www.sciencedirect.com/science/article/pii/S0104001414002000
id doaj-76f9994201884238851baacb04eec368
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Ruggero M. Corso
Davide Cattano
Matteo Buccioli
Elisa Carretta
Stefano Maitan
spellingShingle Ruggero M. Corso
Davide Cattano
Matteo Buccioli
Elisa Carretta
Stefano Maitan
Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway
Brazilian Journal of Anesthesiology
author_facet Ruggero M. Corso
Davide Cattano
Matteo Buccioli
Elisa Carretta
Stefano Maitan
author_sort Ruggero M. Corso
title Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway
title_short Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway
title_full Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway
title_fullStr Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway
title_full_unstemmed Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway
title_sort post analysis simulated correlation of the el-ganzouri airway difficulty score with difficult airway
publisher Elsevier
series Brazilian Journal of Anesthesiology
issn 0104-0014
publishDate 2016-05-01
description Background: Difficult airway (DA) occurs frequently (5–15%) in clinical practice. The El-Ganzouri Risk Index (EGRI) has a high sensitivity for predicting a difficult intubation (DI). However difficult mask ventilation (DMV) was never included in the EGRI. Since DMV was not included in the EGRI assessment, and obstructive sleep apnea (OSA) is also correlated with DMV, a study correlating the prediction of DA and OSA (identified by STOP-Bang questionnaire, SB) seemed important. Methods: We accessed a database previously collected for a post analysis simulation of the airway difficulty predictivity of the EGRI, associated with normal and difficult airway, particularly DMV. As secondary aim, we measured the correlation between the SB prediction system and DA, compared to the EGRI. Results: A total of 2747 patients were included in the study. The proportion of patients with DI was 14.7% (95% CI 13.4–16) and the proportion of patients with DMV was 3.42% (95% CI 2.7–4.1). The incidence of DMV combined with DI was (2.3%). The optimal cutoff value of EGRI was 3. EGRI registered also an higher ability to predict DMV (AUC = 0.76 (95% CI 0.71–0.81)). Adding the SB variables in the logistic model, the AUC increases with the inclusion of “observed apnea” variable (0.83 vs. 0.81, p = 0.03). The area under the ROC curve for the patients with DI and DMV was 0.77 (95% CI 0.72–0.83). Conclusions: This study confirms that the incidence of DA is not negligible and suggests the use of the EGRI as simple bedside predictive score to improve patient safety. Resumo: Justificativa: A via aérea difícil (VAD) ocorre com frequência (5-15%) na prática clínica. O Índice de Risco de El-Ganzouri (EGRI) tem uma alta sensibilidade para prever intubação difícil (ID). No entanto, a ventilação difícil via máscara (VDM) nunca foi incluída no EGRI. Como a VDM não foi incluída na avaliação EGRI e a apneia obstrutiva do sono (AOS) também está correlacionada com a VDM, um estudo correlacionando a previsão da VAD e AOS (identificada pelo questionário STOP-Bang, SB) pareceu importante. Métodos: Nós acessamos um banco de dados previamente coletados para simular uma análise posterior da previsibilidade do EGRI para via aérea difícil, associado à via aérea normal e difícil, particularmente VDM. Como objetivo secundário, avaliamos a correlação entre o sistema de previsão do SB e da VAD, em comparação com o EGRI. Resultados: No total, 2.747 pacientes foram incluídos no estudo. A proporção de pacientes com ID foi de 14,7% (IC de 95%; 13,4-16) e a proporção de pacientes com VDM foi de 3,42% (IC de 95% 2,7-4,1). A incidência da VDM combinada com a de ID foi de 2,3%. O valor de corte ideal de do EGRI foi 3. EGRI também registrou uma capacidade maior de prever VDM (ASC = 0,76 (IC de 95%; 0,71-0,81)). Ao somar as variáveis do SB no modelo logístico, a ASC aumenta com a inclusão da variável “apneia observada” (0,83 vs. 0,81, p = 0,03). A área sob a curva ROC para os pacientes com ID e VDM foi de 0,77 (IC de 95%; 0,72-0,83). Conclusões: Este estudo confirma que a incidência de VAD não é desprezível e sugere o uso do EGRI como um escore de cabeceira preditivo simples para melhorar a segurança do paciente. Keywords: Difficult airway, Predictive score, Sleep apnea, Palavras-chave: Via aérea difícil, Escore preditivo, Apneia do sono
url http://www.sciencedirect.com/science/article/pii/S0104001414002000
work_keys_str_mv AT ruggeromcorso postanalysissimulatedcorrelationoftheelganzouriairwaydifficultyscorewithdifficultairway
AT davidecattano postanalysissimulatedcorrelationoftheelganzouriairwaydifficultyscorewithdifficultairway
AT matteobuccioli postanalysissimulatedcorrelationoftheelganzouriairwaydifficultyscorewithdifficultairway
AT elisacarretta postanalysissimulatedcorrelationoftheelganzouriairwaydifficultyscorewithdifficultairway
AT stefanomaitan postanalysissimulatedcorrelationoftheelganzouriairwaydifficultyscorewithdifficultairway
_version_ 1725048347667988480
spelling doaj-76f9994201884238851baacb04eec3682020-11-25T01:39:54ZengElsevierBrazilian Journal of Anesthesiology0104-00142016-05-01663298303Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airwayRuggero M. Corso0Davide Cattano1Matteo Buccioli2Elisa Carretta3Stefano Maitan4Department of Emergency, Anaesthesia and Intensive Care Section, “G.B. Morgagni-Pierantoni” Hospital, Forlì, Italy; Corresponding author.Department of Anesthesiology, The University of Texas Medical School at Houston, Houston, USADepartment of Emergency, Anaesthesia and Intensive Care Section, “G.B. Morgagni-Pierantoni” Hospital, Forlì, ItalyBiostatistics and Clinical Trials Unit, Institute Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST), Meldola, ItalyDepartment of Emergency, Anaesthesia and Intensive Care Section, “G.B. Morgagni-Pierantoni” Hospital, Forlì, ItalyBackground: Difficult airway (DA) occurs frequently (5–15%) in clinical practice. The El-Ganzouri Risk Index (EGRI) has a high sensitivity for predicting a difficult intubation (DI). However difficult mask ventilation (DMV) was never included in the EGRI. Since DMV was not included in the EGRI assessment, and obstructive sleep apnea (OSA) is also correlated with DMV, a study correlating the prediction of DA and OSA (identified by STOP-Bang questionnaire, SB) seemed important. Methods: We accessed a database previously collected for a post analysis simulation of the airway difficulty predictivity of the EGRI, associated with normal and difficult airway, particularly DMV. As secondary aim, we measured the correlation between the SB prediction system and DA, compared to the EGRI. Results: A total of 2747 patients were included in the study. The proportion of patients with DI was 14.7% (95% CI 13.4–16) and the proportion of patients with DMV was 3.42% (95% CI 2.7–4.1). The incidence of DMV combined with DI was (2.3%). The optimal cutoff value of EGRI was 3. EGRI registered also an higher ability to predict DMV (AUC = 0.76 (95% CI 0.71–0.81)). Adding the SB variables in the logistic model, the AUC increases with the inclusion of “observed apnea” variable (0.83 vs. 0.81, p = 0.03). The area under the ROC curve for the patients with DI and DMV was 0.77 (95% CI 0.72–0.83). Conclusions: This study confirms that the incidence of DA is not negligible and suggests the use of the EGRI as simple bedside predictive score to improve patient safety. Resumo: Justificativa: A via aérea difícil (VAD) ocorre com frequência (5-15%) na prática clínica. O Índice de Risco de El-Ganzouri (EGRI) tem uma alta sensibilidade para prever intubação difícil (ID). No entanto, a ventilação difícil via máscara (VDM) nunca foi incluída no EGRI. Como a VDM não foi incluída na avaliação EGRI e a apneia obstrutiva do sono (AOS) também está correlacionada com a VDM, um estudo correlacionando a previsão da VAD e AOS (identificada pelo questionário STOP-Bang, SB) pareceu importante. Métodos: Nós acessamos um banco de dados previamente coletados para simular uma análise posterior da previsibilidade do EGRI para via aérea difícil, associado à via aérea normal e difícil, particularmente VDM. Como objetivo secundário, avaliamos a correlação entre o sistema de previsão do SB e da VAD, em comparação com o EGRI. Resultados: No total, 2.747 pacientes foram incluídos no estudo. A proporção de pacientes com ID foi de 14,7% (IC de 95%; 13,4-16) e a proporção de pacientes com VDM foi de 3,42% (IC de 95% 2,7-4,1). A incidência da VDM combinada com a de ID foi de 2,3%. O valor de corte ideal de do EGRI foi 3. EGRI também registrou uma capacidade maior de prever VDM (ASC = 0,76 (IC de 95%; 0,71-0,81)). Ao somar as variáveis do SB no modelo logístico, a ASC aumenta com a inclusão da variável “apneia observada” (0,83 vs. 0,81, p = 0,03). A área sob a curva ROC para os pacientes com ID e VDM foi de 0,77 (IC de 95%; 0,72-0,83). Conclusões: Este estudo confirma que a incidência de VAD não é desprezível e sugere o uso do EGRI como um escore de cabeceira preditivo simples para melhorar a segurança do paciente. Keywords: Difficult airway, Predictive score, Sleep apnea, Palavras-chave: Via aérea difícil, Escore preditivo, Apneia do sonohttp://www.sciencedirect.com/science/article/pii/S0104001414002000