Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly

Yaffa Lerman1, Moshe M Werber2, Ilya Fine2, Polina Kemelman11Department of Geriatrics, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; 2Elfi-Tech Ltd, Rehovot, IsraelAbstract: The feasibility of the noninvasive assessment of blood ‘...

Full description

Bibliographic Details
Main Authors: Lerman Y, Werber MM, Fine I, Kemelman P
Format: Article
Language:English
Published: Dove Medical Press 2011-08-01
Series:Journal of Blood Medicine
Online Access:http://www.dovepress.com/preliminary-clinical-evaluation-of-a-noninvasive-device-for-the-measur-a8095
id doaj-77fc964a78b14e988a3bd0bf44f74fba
record_format Article
spelling doaj-77fc964a78b14e988a3bd0bf44f74fba2020-11-24T23:42:30ZengDove Medical PressJournal of Blood Medicine1179-27362011-08-012011default113118Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderlyLerman YWerber MMFine IKemelman PYaffa Lerman1, Moshe M Werber2, Ilya Fine2, Polina Kemelman11Department of Geriatrics, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; 2Elfi-Tech Ltd, Rehovot, IsraelAbstract: The feasibility of the noninvasive assessment of blood ‘coagulability’ (the tendency to coagulate) has been tested by using a novel device, the Thrombo-Monitor. It monitors, by using the principles of near infra-red (NIR) dynamic light scattering, the tendency of blood to create clots. The Thrombo-Monitor observes the very initial changes of blood viscosity, which occurs due to the temporarily induced stasis of capillary blood of the finger. One hundred and fifteen patients aged >65 years (matched by age and sex) participated in the study. Patients were initially divided into four groups based on the patient’s medical therapy. The study groups were: warfarin, enoxaparin, aspirin and/or clopidogrel, and a control group. The medications were given according to the patient’s comorbidities (eg, atrial fibrillation [AF], status post pulmonary embolism [S/p PE], status post cerebrovascular accident [S/p CVA]). The Thrombo-Monitor Index (TMI) is a noninvasive index, derived on the basis of laboratory test results of international normalized ratio (INR) and prothrombin time (PT) values. For the group of patients who were treated only with warfarin, TMI was adjusted by using the jackknife statistical approach to create maximum correlation and linearity with INR and PT values that ranged from 1.1 to 5.0. For all warfarin patients (N = 35) the TMI was found to have a good correlation with INR and PT values (R2 = 0.64, P < 0.00001); mean TMI = 1.86 (SD = 0.91); mean INR and PT = 2.3 (SD = 0.91). The calibration curve thus generated was used to calculate the TMI for all other groups: aspirin group, mean TMI = 1.3 (SD = 0.14, N = 23), corresponding approximately to INR and PT values of 1.036; enoxaparin group (N = 24), mean TMI = 1.34 (SD = 0.304), corresponding to mean INR and PT values of 1.07 (SD = 0.3); control group, INR and PT ≥ 1 (N = 32), mean TMI = 1.24 (SD = 0.32). R2 of all control and warfarin patients (N = 67) was 0.55 (P < 0.00001). In summary, the newly introduced TMI index is significantly correlated with INR and PT values.Keywords: anticoagulant monitoring, elderly, noninvasive coagulability index, noninvasive measurementhttp://www.dovepress.com/preliminary-clinical-evaluation-of-a-noninvasive-device-for-the-measur-a8095
collection DOAJ
language English
format Article
sources DOAJ
author Lerman Y
Werber MM
Fine I
Kemelman P
spellingShingle Lerman Y
Werber MM
Fine I
Kemelman P
Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
Journal of Blood Medicine
author_facet Lerman Y
Werber MM
Fine I
Kemelman P
author_sort Lerman Y
title Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
title_short Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
title_full Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
title_fullStr Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
title_full_unstemmed Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
title_sort preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly
publisher Dove Medical Press
series Journal of Blood Medicine
issn 1179-2736
publishDate 2011-08-01
description Yaffa Lerman1, Moshe M Werber2, Ilya Fine2, Polina Kemelman11Department of Geriatrics, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; 2Elfi-Tech Ltd, Rehovot, IsraelAbstract: The feasibility of the noninvasive assessment of blood ‘coagulability’ (the tendency to coagulate) has been tested by using a novel device, the Thrombo-Monitor. It monitors, by using the principles of near infra-red (NIR) dynamic light scattering, the tendency of blood to create clots. The Thrombo-Monitor observes the very initial changes of blood viscosity, which occurs due to the temporarily induced stasis of capillary blood of the finger. One hundred and fifteen patients aged >65 years (matched by age and sex) participated in the study. Patients were initially divided into four groups based on the patient’s medical therapy. The study groups were: warfarin, enoxaparin, aspirin and/or clopidogrel, and a control group. The medications were given according to the patient’s comorbidities (eg, atrial fibrillation [AF], status post pulmonary embolism [S/p PE], status post cerebrovascular accident [S/p CVA]). The Thrombo-Monitor Index (TMI) is a noninvasive index, derived on the basis of laboratory test results of international normalized ratio (INR) and prothrombin time (PT) values. For the group of patients who were treated only with warfarin, TMI was adjusted by using the jackknife statistical approach to create maximum correlation and linearity with INR and PT values that ranged from 1.1 to 5.0. For all warfarin patients (N = 35) the TMI was found to have a good correlation with INR and PT values (R2 = 0.64, P < 0.00001); mean TMI = 1.86 (SD = 0.91); mean INR and PT = 2.3 (SD = 0.91). The calibration curve thus generated was used to calculate the TMI for all other groups: aspirin group, mean TMI = 1.3 (SD = 0.14, N = 23), corresponding approximately to INR and PT values of 1.036; enoxaparin group (N = 24), mean TMI = 1.34 (SD = 0.304), corresponding to mean INR and PT values of 1.07 (SD = 0.3); control group, INR and PT ≥ 1 (N = 32), mean TMI = 1.24 (SD = 0.32). R2 of all control and warfarin patients (N = 67) was 0.55 (P < 0.00001). In summary, the newly introduced TMI index is significantly correlated with INR and PT values.Keywords: anticoagulant monitoring, elderly, noninvasive coagulability index, noninvasive measurement
url http://www.dovepress.com/preliminary-clinical-evaluation-of-a-noninvasive-device-for-the-measur-a8095
work_keys_str_mv AT lermany preliminaryclinicalevaluationofanoninvasivedeviceforthemeasurementofcoagulabilityintheelderly
AT werbermm preliminaryclinicalevaluationofanoninvasivedeviceforthemeasurementofcoagulabilityintheelderly
AT finei preliminaryclinicalevaluationofanoninvasivedeviceforthemeasurementofcoagulabilityintheelderly
AT kemelmanp preliminaryclinicalevaluationofanoninvasivedeviceforthemeasurementofcoagulabilityintheelderly
_version_ 1725504289424539648