Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry

Introduction: Leukoreduced (LR) blood components are used for the prevention of several transfusion adverse effects. Advancement in technology has led to newer methods to count residual leukocytes (rWBC) which miss detection on most standard automated hematology analyzers. Materials and Methods: Sam...

Full description

Bibliographic Details
Main Authors: Rizwan Javed, Sabita Basu, Deepak Kumar Mishra
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Global Journal of Transfusion Medicine
Subjects:
Online Access:http://www.gjtmonline.com/article.asp?issn=2468-8398;year=2016;volume=1;issue=2;spage=43;epage=45;aulast=Javed
id doaj-7820139ecf3946b19d25c3d5f242b25a
record_format Article
spelling doaj-7820139ecf3946b19d25c3d5f242b25a2020-11-24T22:03:05ZengWolters Kluwer Medknow PublicationsGlobal Journal of Transfusion Medicine2468-83982455-88932016-01-0112434510.4103/2455-8893.189854Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometryRizwan JavedSabita BasuDeepak Kumar MishraIntroduction: Leukoreduced (LR) blood components are used for the prevention of several transfusion adverse effects. Advancement in technology has led to newer methods to count residual leukocytes (rWBC) which miss detection on most standard automated hematology analyzers. Materials and Methods: Samples from thirty eight platelet concentrates (prepared by Buffy-coat method) were randomly taken on the day of preparation for rWBC count using Nageotte's chamber and flowcytometer. Results: The rWBC count on Nageotte's ranged from 2.5 WBC/μL to a maximum of 600 WBC/μL where as the flowcytometric count had a lowest of 1.97 WBC/μL to a highest of 740 WBC/μL. We found that the WBC counts using the Nageotte's method and flowcytometeric method are highly correlated. The concordance correlation coefficient or intraclass correlation coefficient which is a measure of reliability was 0.78 Conclusion: In view of the high concordance in correlation coefficient between the two methods, Nageotte's method could be skillfully performed for assessing leukoreduction in LR platelet concentrates of resource constrained blood banks of developing nations.http://www.gjtmonline.com/article.asp?issn=2468-8398;year=2016;volume=1;issue=2;spage=43;epage=45;aulast=JavedFlow cytometryleukoreducedNageotte's
collection DOAJ
language English
format Article
sources DOAJ
author Rizwan Javed
Sabita Basu
Deepak Kumar Mishra
spellingShingle Rizwan Javed
Sabita Basu
Deepak Kumar Mishra
Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry
Global Journal of Transfusion Medicine
Flow cytometry
leukoreduced
Nageotte's
author_facet Rizwan Javed
Sabita Basu
Deepak Kumar Mishra
author_sort Rizwan Javed
title Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry
title_short Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry
title_full Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry
title_fullStr Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry
title_full_unstemmed Evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: Nageotte's method and flow cytometry
title_sort evaluation of two methods for counting residual leukocytes in leuko-reduced platelets: nageotte's method and flow cytometry
publisher Wolters Kluwer Medknow Publications
series Global Journal of Transfusion Medicine
issn 2468-8398
2455-8893
publishDate 2016-01-01
description Introduction: Leukoreduced (LR) blood components are used for the prevention of several transfusion adverse effects. Advancement in technology has led to newer methods to count residual leukocytes (rWBC) which miss detection on most standard automated hematology analyzers. Materials and Methods: Samples from thirty eight platelet concentrates (prepared by Buffy-coat method) were randomly taken on the day of preparation for rWBC count using Nageotte's chamber and flowcytometer. Results: The rWBC count on Nageotte's ranged from 2.5 WBC/μL to a maximum of 600 WBC/μL where as the flowcytometric count had a lowest of 1.97 WBC/μL to a highest of 740 WBC/μL. We found that the WBC counts using the Nageotte's method and flowcytometeric method are highly correlated. The concordance correlation coefficient or intraclass correlation coefficient which is a measure of reliability was 0.78 Conclusion: In view of the high concordance in correlation coefficient between the two methods, Nageotte's method could be skillfully performed for assessing leukoreduction in LR platelet concentrates of resource constrained blood banks of developing nations.
topic Flow cytometry
leukoreduced
Nageotte's
url http://www.gjtmonline.com/article.asp?issn=2468-8398;year=2016;volume=1;issue=2;spage=43;epage=45;aulast=Javed
work_keys_str_mv AT rizwanjaved evaluationoftwomethodsforcountingresidualleukocytesinleukoreducedplateletsnageottesmethodandflowcytometry
AT sabitabasu evaluationoftwomethodsforcountingresidualleukocytesinleukoreducedplateletsnageottesmethodandflowcytometry
AT deepakkumarmishra evaluationoftwomethodsforcountingresidualleukocytesinleukoreducedplateletsnageottesmethodandflowcytometry
_version_ 1725833276744007680