Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution

In this paper, a sensitive constrained integer linear programming approach is formulated for the optimal allocation of Phasor Measurement Units (PMUs) in a power system network to obtain state estimation. In this approach, sensitive buses along with zero injection buses (ZIB) are considered for opti...

Full description

Bibliographic Details
Main Authors: R. Manam, S. R. Rayapudi
Format: Article
Language:English
Published: D. G. Pylarinos 2017-12-01
Series:Engineering, Technology & Applied Science Research
Subjects:
bus
pmu
Online Access:https://etasr.com/index.php/ETASR/article/view/1542
id doaj-78c8e5399a444fc3b16a09ed0bf00951
record_format Article
spelling doaj-78c8e5399a444fc3b16a09ed0bf009512020-12-02T15:58:37ZengD. G. PylarinosEngineering, Technology & Applied Science Research2241-44871792-80362017-12-0176396Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation SolutionR. Manam0S. R. Rayapudi1Electrical and Electronics Engineering Department, Jawaharlal Nehru Technological University, Kakinada, Kakinada, IndiaElectrical and Electronics Engineering Department, Jawaharlal Nehru Technological University, Kakinada, Kakinada, IndiaIn this paper, a sensitive constrained integer linear programming approach is formulated for the optimal allocation of Phasor Measurement Units (PMUs) in a power system network to obtain state estimation. In this approach, sensitive buses along with zero injection buses (ZIB) are considered for optimal allocation of PMUs in the network to generate state estimation solutions. Sensitive buses are evolved from the mean of bus voltages subjected to increase of load consistently up to 50%. Sensitive buses are ranked in order to place PMUs. Sensitive constrained optimal PMU allocation in case of single line and no line contingency are considered in observability analysis to ensure protection and control of power system from abnormal conditions. Modeling of ZIB constraints is included to minimize the number of PMU network allocations. This paper presents optimal allocation of PMU at sensitive buses with zero injection modeling, considering cost criteria and redundancy to increase the accuracy of state estimation solution without losing observability of the whole system. Simulations are carried out on IEEE 14, 30 and 57 bus systems and results obtained are compared with traditional and other state estimation methods available in the literature, to demonstrate the effectiveness of the proposed method. https://etasr.com/index.php/ETASR/article/view/1542sensitivebusobservabilityphasormeasurementpmu
collection DOAJ
language English
format Article
sources DOAJ
author R. Manam
S. R. Rayapudi
spellingShingle R. Manam
S. R. Rayapudi
Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution
Engineering, Technology & Applied Science Research
sensitive
bus
observability
phasor
measurement
pmu
author_facet R. Manam
S. R. Rayapudi
author_sort R. Manam
title Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution
title_short Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution
title_full Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution
title_fullStr Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution
title_full_unstemmed Sensitive Constrained Optimal PMU Allocation with Complete Observability for State Estimation Solution
title_sort sensitive constrained optimal pmu allocation with complete observability for state estimation solution
publisher D. G. Pylarinos
series Engineering, Technology & Applied Science Research
issn 2241-4487
1792-8036
publishDate 2017-12-01
description In this paper, a sensitive constrained integer linear programming approach is formulated for the optimal allocation of Phasor Measurement Units (PMUs) in a power system network to obtain state estimation. In this approach, sensitive buses along with zero injection buses (ZIB) are considered for optimal allocation of PMUs in the network to generate state estimation solutions. Sensitive buses are evolved from the mean of bus voltages subjected to increase of load consistently up to 50%. Sensitive buses are ranked in order to place PMUs. Sensitive constrained optimal PMU allocation in case of single line and no line contingency are considered in observability analysis to ensure protection and control of power system from abnormal conditions. Modeling of ZIB constraints is included to minimize the number of PMU network allocations. This paper presents optimal allocation of PMU at sensitive buses with zero injection modeling, considering cost criteria and redundancy to increase the accuracy of state estimation solution without losing observability of the whole system. Simulations are carried out on IEEE 14, 30 and 57 bus systems and results obtained are compared with traditional and other state estimation methods available in the literature, to demonstrate the effectiveness of the proposed method.
topic sensitive
bus
observability
phasor
measurement
pmu
url https://etasr.com/index.php/ETASR/article/view/1542
work_keys_str_mv AT rmanam sensitiveconstrainedoptimalpmuallocationwithcompleteobservabilityforstateestimationsolution
AT srrayapudi sensitiveconstrainedoptimalpmuallocationwithcompleteobservabilityforstateestimationsolution
_version_ 1724405364250640384