Experimental study of grouted sleeve lapping connector under tensile load

The performance of the grouted sleeve lapping connector that is used to connect reinforcement bars in a precast concrete structure is studied. A total of 63 specimens, varying in bar diameter and lap length, were tested under tensile load. The failure modes, ultimate tensile strength values and load...

Full description

Bibliographic Details
Main Authors: Yu Qiong, Xu Zhiyuan
Format: Article
Language:English
Published: Croatian Association of Civil Engineers 2017-07-01
Series:Građevinar
Online Access:https://doi.org/10.14256/JCE.1476.2015

Similar Items