Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.

BACKGROUND: Molecular methods have great potential for sensitive parasite detection in the diagnosis of human African trypanosomiasis (HAT), but the requirements in terms of laboratory infrastructure limit their use to reference centres. A recently developed assay detects the Trypanozoon repetitive...

Full description

Bibliographic Details
Main Authors: Patrick Mitashi, Epco Hasker, Dieudonné Mumba Ngoyi, Pati Patient Pyana, Veerle Lejon, Wim Van der Veken, Pascal Lutumba, Philippe Büscher, Marleen Boelaert, Stijn Deborggraeve
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2013-01-01
Series:PLoS Neglected Tropical Diseases
Online Access:http://europepmc.org/articles/PMC3798548?pdf=render
id doaj-7a28a4f90b2849188a47ca99a3aa8a26
record_format Article
spelling doaj-7a28a4f90b2849188a47ca99a3aa8a262020-11-24T23:57:13ZengPublic Library of Science (PLoS)PLoS Neglected Tropical Diseases1935-27271935-27352013-01-01710e250410.1371/journal.pntd.0002504Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.Patrick MitashiEpco HaskerDieudonné Mumba NgoyiPati Patient PyanaVeerle LejonWim Van der VekenPascal LutumbaPhilippe BüscherMarleen BoelaertStijn DeborggraeveBACKGROUND: Molecular methods have great potential for sensitive parasite detection in the diagnosis of human African trypanosomiasis (HAT), but the requirements in terms of laboratory infrastructure limit their use to reference centres. A recently developed assay detects the Trypanozoon repetitive insertion mobile element (RIME) DNA under isothermal amplification conditions and has been transformed into a ready-to-use kit format, the Loopamp Trypanosoma brucei. In this study, we have evaluated the diagnostic performance of the Loopamp Trypanosoma brucei assay (hereafter called LAMP) in confirmed T.b. gambiense HAT patients, HAT suspects and healthy endemic controls from the Democratic Republic of the Congo (DRC). METHODOLOGY/PRINCIPAL FINDINGS: 142 T.b. gambiense HAT patients, 111 healthy endemic controls and 97 HAT suspects with unconfirmed status were included in this retrospective evaluation. Reference standard tests were parasite detection in blood, lymph or cerebrospinal fluid. Archived DNA from blood of all study participants was analysed in duplicate with LAMP. Sensitivity of LAMP in parasitologically confirmed cases was 87.3% (95% CI 80.9-91.8%) in the first run and 93.0% (95% CI 87.5-96.1%) in the second run. Specificity in healthy controls was 92.8% (95% CI 86.4-96.3%) in the first run and 96.4% (95% CI 91.1-98.6%) in the second run. Reproducibility was excellent with a kappa value of 0.81. CONCLUSIONS/SIGNIFICANCE: In this laboratory-based study, the Loopamp Trypanosoma brucei Detection Kit showed good diagnostic accuracy and excellent reproducibility. Further studies are needed to assess the feasibility of its routine use for diagnosis of HAT under field conditions.http://europepmc.org/articles/PMC3798548?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Patrick Mitashi
Epco Hasker
Dieudonné Mumba Ngoyi
Pati Patient Pyana
Veerle Lejon
Wim Van der Veken
Pascal Lutumba
Philippe Büscher
Marleen Boelaert
Stijn Deborggraeve
spellingShingle Patrick Mitashi
Epco Hasker
Dieudonné Mumba Ngoyi
Pati Patient Pyana
Veerle Lejon
Wim Van der Veken
Pascal Lutumba
Philippe Büscher
Marleen Boelaert
Stijn Deborggraeve
Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.
PLoS Neglected Tropical Diseases
author_facet Patrick Mitashi
Epco Hasker
Dieudonné Mumba Ngoyi
Pati Patient Pyana
Veerle Lejon
Wim Van der Veken
Pascal Lutumba
Philippe Büscher
Marleen Boelaert
Stijn Deborggraeve
author_sort Patrick Mitashi
title Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.
title_short Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.
title_full Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.
title_fullStr Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.
title_full_unstemmed Diagnostic accuracy of loopamp Trypanosoma brucei detection kit for diagnosis of human African trypanosomiasis in clinical samples.
title_sort diagnostic accuracy of loopamp trypanosoma brucei detection kit for diagnosis of human african trypanosomiasis in clinical samples.
publisher Public Library of Science (PLoS)
series PLoS Neglected Tropical Diseases
issn 1935-2727
1935-2735
publishDate 2013-01-01
description BACKGROUND: Molecular methods have great potential for sensitive parasite detection in the diagnosis of human African trypanosomiasis (HAT), but the requirements in terms of laboratory infrastructure limit their use to reference centres. A recently developed assay detects the Trypanozoon repetitive insertion mobile element (RIME) DNA under isothermal amplification conditions and has been transformed into a ready-to-use kit format, the Loopamp Trypanosoma brucei. In this study, we have evaluated the diagnostic performance of the Loopamp Trypanosoma brucei assay (hereafter called LAMP) in confirmed T.b. gambiense HAT patients, HAT suspects and healthy endemic controls from the Democratic Republic of the Congo (DRC). METHODOLOGY/PRINCIPAL FINDINGS: 142 T.b. gambiense HAT patients, 111 healthy endemic controls and 97 HAT suspects with unconfirmed status were included in this retrospective evaluation. Reference standard tests were parasite detection in blood, lymph or cerebrospinal fluid. Archived DNA from blood of all study participants was analysed in duplicate with LAMP. Sensitivity of LAMP in parasitologically confirmed cases was 87.3% (95% CI 80.9-91.8%) in the first run and 93.0% (95% CI 87.5-96.1%) in the second run. Specificity in healthy controls was 92.8% (95% CI 86.4-96.3%) in the first run and 96.4% (95% CI 91.1-98.6%) in the second run. Reproducibility was excellent with a kappa value of 0.81. CONCLUSIONS/SIGNIFICANCE: In this laboratory-based study, the Loopamp Trypanosoma brucei Detection Kit showed good diagnostic accuracy and excellent reproducibility. Further studies are needed to assess the feasibility of its routine use for diagnosis of HAT under field conditions.
url http://europepmc.org/articles/PMC3798548?pdf=render
work_keys_str_mv AT patrickmitashi diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT epcohasker diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT dieudonnemumbangoyi diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT patipatientpyana diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT veerlelejon diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT wimvanderveken diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT pascallutumba diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT philippebuscher diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT marleenboelaert diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
AT stijndeborggraeve diagnosticaccuracyofloopamptrypanosomabruceidetectionkitfordiagnosisofhumanafricantrypanosomiasisinclinicalsamples
_version_ 1725454985055961088