Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures

The co-immobilization of GOx and ferrocene in a polymeric matrix by a one-step simple method is presented. This procedure to immobilize ferrocene as mediator implies the absence of modification of the monomer or the enzyme that would lead to the loss of its activity. Ferrocene incorporation results...

Full description

Bibliographic Details
Main Authors: Fiorito Pablo A., Torresi Susana I. Córdoba de
Format: Article
Language:English
Published: Sociedade Brasileira de Química 2001-01-01
Series:Journal of the Brazilian Chemical Society
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000600007
id doaj-7ad200dcb78c4341aa703c0beed4338b
record_format Article
spelling doaj-7ad200dcb78c4341aa703c0beed4338b2020-11-25T01:01:36ZengSociedade Brasileira de QuímicaJournal of the Brazilian Chemical Society0103-50532001-01-01126729733Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water MixturesFiorito Pablo A.Torresi Susana I. Córdoba deThe co-immobilization of GOx and ferrocene in a polymeric matrix by a one-step simple method is presented. This procedure to immobilize ferrocene as mediator implies the absence of modification of the monomer or the enzyme that would lead to the loss of its activity. Ferrocene incorporation results in an increase of sensitivity compared with the sensor prepared without the redox mediator (1.5 vs 0.23 muA mmol-1 L cm-2) and the decrease of the working potential to 0.4 V. The prepared sensor shows linear response till 10 mmol L-1 and response time of 2 s, in addition to reasonable stability after one week.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000600007amperometric biosensorpolypyrrolglucose detectionferrocene mediation
collection DOAJ
language English
format Article
sources DOAJ
author Fiorito Pablo A.
Torresi Susana I. Córdoba de
spellingShingle Fiorito Pablo A.
Torresi Susana I. Córdoba de
Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures
Journal of the Brazilian Chemical Society
amperometric biosensor
polypyrrol
glucose detection
ferrocene mediation
author_facet Fiorito Pablo A.
Torresi Susana I. Córdoba de
author_sort Fiorito Pablo A.
title Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures
title_short Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures
title_full Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures
title_fullStr Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures
title_full_unstemmed Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures
title_sort glucose amperometric biosensor based on the co-immobilization of glucose oxidase (gox) and ferrocene in poly(pyrrole) generated from ethanol / water mixtures
publisher Sociedade Brasileira de Química
series Journal of the Brazilian Chemical Society
issn 0103-5053
publishDate 2001-01-01
description The co-immobilization of GOx and ferrocene in a polymeric matrix by a one-step simple method is presented. This procedure to immobilize ferrocene as mediator implies the absence of modification of the monomer or the enzyme that would lead to the loss of its activity. Ferrocene incorporation results in an increase of sensitivity compared with the sensor prepared without the redox mediator (1.5 vs 0.23 muA mmol-1 L cm-2) and the decrease of the working potential to 0.4 V. The prepared sensor shows linear response till 10 mmol L-1 and response time of 2 s, in addition to reasonable stability after one week.
topic amperometric biosensor
polypyrrol
glucose detection
ferrocene mediation
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000600007
work_keys_str_mv AT fioritopabloa glucoseamperometricbiosensorbasedonthecoimmobilizationofglucoseoxidasegoxandferroceneinpolypyrrolegeneratedfromethanolwatermixtures
AT torresisusanaicordobade glucoseamperometricbiosensorbasedonthecoimmobilizationofglucoseoxidasegoxandferroceneinpolypyrrolegeneratedfromethanolwatermixtures
_version_ 1725208338942132224