Time-efficient myocardial contrast partition coefficient measurement from early enhancement with magnetic resonance imaging.

OBJECTIVE: Our purpose was to validate an early enhancement time point for accurately measuring the myocardial contrast partition coefficient (lambda) using dynamic-equilibrium magnetic resonance imaging. MATERIALS AND METHODS: The pre- and post-contrast longitudinal relaxation rates (reciprocal of...

Full description

Bibliographic Details
Main Authors: Shi-Jun Zhang, Yi-Xiang Wang, Jing Yuan, Jiyang Jin, Yuan-Cheng Wang, Di Chang, Dehe Weng, Andreas Greiser, Shenghong Ju
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3965516?pdf=render
Description
Summary:OBJECTIVE: Our purpose was to validate an early enhancement time point for accurately measuring the myocardial contrast partition coefficient (lambda) using dynamic-equilibrium magnetic resonance imaging. MATERIALS AND METHODS: The pre- and post-contrast longitudinal relaxation rates (reciprocal of T1) of the interventricular septum (R1(m)) and blood pool (R1(b)) were obtained from fifteen healthy volunteers and three diabetic patients with hypertension using two optimized T1 mapping sequences (modified Look-Locker inversion recovery) on a 3-Tesla magnetic resonance scanner. Reference lambda values were calculated as the slope of the regression line of R1(m) versus R1(b) at dynamic equilibrium (multi-point regression method). The simplified pre-/post-enhancement two-acquisition method (two-point method) was used to calculate lambda by relating the change in R1(m) and R1(b) using different protocols according to the acquisition stage of the post-enhancement data point. The agreement with the referential method was tested by calculating Pearson's correlation coefficient and the intra-class correlation coefficient. RESULTS: The lambda values measured by the two-point method increased (from 0.479 ± 0.041 to 0.534 ± 0.043) over time from 6 to 45 minutes after contrast and exhibited good correlation with the reference at each time point (r ≥ 0.875, p<0.05). The intra-class correlation coefficient on absolute agreement with the reference lambda was 0.946, 0.929 and 0.922 at the 6th, 7th and 8th minutes and dropped from 0.878 to 0.403 from the 9th minute on. CONCLUSIONS: The time-efficient two-point method at 6-8 minutes after the Gd-DTPA bolus injection exhibited good agreement with the multi-point regression method and can be applied for accurate lambda measurement in normal myocardium.
ISSN:1932-6203