Improving the efficiency of power supply systems through the combined effect of voltage distortion

In most cases, any abnormal mode in the distribution electrical network is eliminated by the action of relay protection and automation devices (RPA), i.e. - there is a shutdown of the damaged item. It is much more difficult to constantly maintain the normal key indicators of the quality of electrica...

Full description

Bibliographic Details
Main Authors: V. I. Zatsepina, E. P. Zatsepin, P. I. Skomorokhov
Format: Article
Language:English
Published: Kazan State Power Engineering University 2019-12-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1107
id doaj-7bfd13bf0e6740a8b14d8572dce2996c
record_format Article
spelling doaj-7bfd13bf0e6740a8b14d8572dce2996c2021-07-28T13:16:32ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032019-12-01215798610.30724/1998-9903-2019-21-5-79-86621Improving the efficiency of power supply systems through the combined effect of voltage distortionV. I. Zatsepina0E. P. Zatsepin1P. I. Skomorokhov2Lipetsk State Technical UniversityLipetsk State Technical UniversityBranch of JSC «SO UES» Lipetsk RDMIn most cases, any abnormal mode in the distribution electrical network is eliminated by the action of relay protection and automation devices (RPA), i.e. - there is a shutdown of the damaged item. It is much more difficult to constantly maintain the normal key indicators of the quality of electrical energy in the network. With the advent of controlled voltage converters based on transistors IGCT and IGBT, static synchronous compensators STATCOM were developed. The main disadvantage of this kind of device is that the control output generated by them is static. Under conditions of increased likelihood of abnormal conditions, their dynamic compensation will be much more effective. In the process of research, the methods of dynamic continuous action of voltage on a sinusoid in a distribution electric network were used. The development of a theoretical approach was accompanied by constant monitoring of existing and developed technical solutions associated with the task set in the work. The object of the study was the distribution electrical network of industrial enterprises with a sharply alternating nature of negative network perturbations. A method has been developed for dynamic suppression of amplitude-phase voltage distortions on the basis of restoring the voltage curve due to the continuous introduction of a compensation voltage curve into the network via a booster transformer. A faster formation of the control action in comparison with analogues allows us to more effectively respond to negative network perturbations in distribution networks, especially if the nature of their occurrence changes dramatically. The proposed method is designed to maintain the quality of electricity within acceptable limits in accordance with the requirements of Russian State Standard 32144-2013.https://www.energyret.ru/jour/article/view/1107power qualityvoltage regulationvoltage distortionnetwork disturbancesdynamic compensation
collection DOAJ
language English
format Article
sources DOAJ
author V. I. Zatsepina
E. P. Zatsepin
P. I. Skomorokhov
spellingShingle V. I. Zatsepina
E. P. Zatsepin
P. I. Skomorokhov
Improving the efficiency of power supply systems through the combined effect of voltage distortion
Известия высших учебных заведений: Проблемы энергетики
power quality
voltage regulation
voltage distortion
network disturbances
dynamic compensation
author_facet V. I. Zatsepina
E. P. Zatsepin
P. I. Skomorokhov
author_sort V. I. Zatsepina
title Improving the efficiency of power supply systems through the combined effect of voltage distortion
title_short Improving the efficiency of power supply systems through the combined effect of voltage distortion
title_full Improving the efficiency of power supply systems through the combined effect of voltage distortion
title_fullStr Improving the efficiency of power supply systems through the combined effect of voltage distortion
title_full_unstemmed Improving the efficiency of power supply systems through the combined effect of voltage distortion
title_sort improving the efficiency of power supply systems through the combined effect of voltage distortion
publisher Kazan State Power Engineering University
series Известия высших учебных заведений: Проблемы энергетики
issn 1998-9903
publishDate 2019-12-01
description In most cases, any abnormal mode in the distribution electrical network is eliminated by the action of relay protection and automation devices (RPA), i.e. - there is a shutdown of the damaged item. It is much more difficult to constantly maintain the normal key indicators of the quality of electrical energy in the network. With the advent of controlled voltage converters based on transistors IGCT and IGBT, static synchronous compensators STATCOM were developed. The main disadvantage of this kind of device is that the control output generated by them is static. Under conditions of increased likelihood of abnormal conditions, their dynamic compensation will be much more effective. In the process of research, the methods of dynamic continuous action of voltage on a sinusoid in a distribution electric network were used. The development of a theoretical approach was accompanied by constant monitoring of existing and developed technical solutions associated with the task set in the work. The object of the study was the distribution electrical network of industrial enterprises with a sharply alternating nature of negative network perturbations. A method has been developed for dynamic suppression of amplitude-phase voltage distortions on the basis of restoring the voltage curve due to the continuous introduction of a compensation voltage curve into the network via a booster transformer. A faster formation of the control action in comparison with analogues allows us to more effectively respond to negative network perturbations in distribution networks, especially if the nature of their occurrence changes dramatically. The proposed method is designed to maintain the quality of electricity within acceptable limits in accordance with the requirements of Russian State Standard 32144-2013.
topic power quality
voltage regulation
voltage distortion
network disturbances
dynamic compensation
url https://www.energyret.ru/jour/article/view/1107
work_keys_str_mv AT vizatsepina improvingtheefficiencyofpowersupplysystemsthroughthecombinedeffectofvoltagedistortion
AT epzatsepin improvingtheefficiencyofpowersupplysystemsthroughthecombinedeffectofvoltagedistortion
AT piskomorokhov improvingtheefficiencyofpowersupplysystemsthroughthecombinedeffectofvoltagedistortion
_version_ 1721275756441501696