Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience

Purpose. Postoperative hemorrhage is fortunately uncommon but potentially life-threatening complication of thyroid surgery that increases the postoperative morbidity and the hospital stay. In this study we compare the efficacy of collagen patch coated with human fibrinogen and human thrombin (CFTP)...

Full description

Bibliographic Details
Main Authors: Nicola Tartaglia, Alessandra Di Lascia, Vincenzo Lizzi, Pasquale Cianci, Alberto Fersini, Antonio Ambrosi, Vincenzo Neri
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:Surgery Research and Practice
Online Access:http://dx.doi.org/10.1155/2016/3058754
id doaj-7c5a70397cd24096ab6e7ebaaef54238
record_format Article
spelling doaj-7c5a70397cd24096ab6e7ebaaef542382020-11-24T21:03:05ZengHindawi LimitedSurgery Research and Practice2356-77592356-61242016-01-01201610.1155/2016/30587543058754Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our ExperienceNicola Tartaglia0Alessandra Di Lascia1Vincenzo Lizzi2Pasquale Cianci3Alberto Fersini4Antonio Ambrosi5Vincenzo Neri6Department of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyDepartment of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyDepartment of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyDepartment of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyDepartment of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyDepartment of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyDepartment of Medical and Surgical Science, University of Foggia, Luigi Pinto Street 1, 71122 Foggia, ItalyPurpose. Postoperative hemorrhage is fortunately uncommon but potentially life-threatening complication of thyroid surgery that increases the postoperative morbidity and the hospital stay. In this study we compare the efficacy of collagen patch coated with human fibrinogen and human thrombin (CFTP) (group C) and oxidized regenerated cellulose gauze (group B) versus traditional hemostatic procedures (group A) in thyroid surgery. Methods. From January 2011 to December 2013, 226 were eligible for our prospective, nonrandomized, comparative study. Patients requiring a video-assisted thyroidectomy without drain, “near total,” or hemithyroidectomy were excluded. Other exclusion criteria were a diagnosis of malignancy, substernal goiter, disorders of hemostasis or coagulation, and Graves or hyperfunctioning thyroid diseases. Outcomes included duration of operation, drainage volume, and postoperative complications. Results. Our results show a significant reduction in drainage volume in group C in comparison with the other two groups. In group C there was no bleeding but the limited numbers do not make this result significant. There were no differences in terms of other complications, except for the incidence of seroma in group B. Conclusion. The use of CFTP reduces the drainage volume, potentially the bleeding complications, and the hospital stay. These findings confirm the efficacy of CFTP, encouraging its use in thyroid surgery.http://dx.doi.org/10.1155/2016/3058754
collection DOAJ
language English
format Article
sources DOAJ
author Nicola Tartaglia
Alessandra Di Lascia
Vincenzo Lizzi
Pasquale Cianci
Alberto Fersini
Antonio Ambrosi
Vincenzo Neri
spellingShingle Nicola Tartaglia
Alessandra Di Lascia
Vincenzo Lizzi
Pasquale Cianci
Alberto Fersini
Antonio Ambrosi
Vincenzo Neri
Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience
Surgery Research and Practice
author_facet Nicola Tartaglia
Alessandra Di Lascia
Vincenzo Lizzi
Pasquale Cianci
Alberto Fersini
Antonio Ambrosi
Vincenzo Neri
author_sort Nicola Tartaglia
title Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience
title_short Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience
title_full Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience
title_fullStr Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience
title_full_unstemmed Haemostasis in Thyroid Surgery: Collagen-Fibrinogen-Thrombin Patch versus Cellulose Gauze—Our Experience
title_sort haemostasis in thyroid surgery: collagen-fibrinogen-thrombin patch versus cellulose gauze—our experience
publisher Hindawi Limited
series Surgery Research and Practice
issn 2356-7759
2356-6124
publishDate 2016-01-01
description Purpose. Postoperative hemorrhage is fortunately uncommon but potentially life-threatening complication of thyroid surgery that increases the postoperative morbidity and the hospital stay. In this study we compare the efficacy of collagen patch coated with human fibrinogen and human thrombin (CFTP) (group C) and oxidized regenerated cellulose gauze (group B) versus traditional hemostatic procedures (group A) in thyroid surgery. Methods. From January 2011 to December 2013, 226 were eligible for our prospective, nonrandomized, comparative study. Patients requiring a video-assisted thyroidectomy without drain, “near total,” or hemithyroidectomy were excluded. Other exclusion criteria were a diagnosis of malignancy, substernal goiter, disorders of hemostasis or coagulation, and Graves or hyperfunctioning thyroid diseases. Outcomes included duration of operation, drainage volume, and postoperative complications. Results. Our results show a significant reduction in drainage volume in group C in comparison with the other two groups. In group C there was no bleeding but the limited numbers do not make this result significant. There were no differences in terms of other complications, except for the incidence of seroma in group B. Conclusion. The use of CFTP reduces the drainage volume, potentially the bleeding complications, and the hospital stay. These findings confirm the efficacy of CFTP, encouraging its use in thyroid surgery.
url http://dx.doi.org/10.1155/2016/3058754
work_keys_str_mv AT nicolatartaglia haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
AT alessandradilascia haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
AT vincenzolizzi haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
AT pasqualecianci haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
AT albertofersini haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
AT antonioambrosi haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
AT vincenzoneri haemostasisinthyroidsurgerycollagenfibrinogenthrombinpatchversuscellulosegauzeourexperience
_version_ 1716774214588956672