The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain

Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-tra...

Full description

Bibliographic Details
Main Authors: Aize Kijlstra, Bastiaan G. Meerburg, Willem Haasnoot, Ron L. A. P. Hoogenboom, Imke J. M. De Boer, Jeerasak Chobtang
Format: Article
Language:English
Published: MDPI AG 2011-12-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/11/12/11692/
id doaj-7cbb48b594314c11987fec3171f1cf9e
record_format Article
spelling doaj-7cbb48b594314c11987fec3171f1cf9e2020-11-25T00:20:56ZengMDPI AGSensors1424-82202011-12-011112116921171610.3390/s111211692The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food ChainAize KijlstraBastiaan G. MeerburgWillem HaasnootRon L. A. P. HoogenboomImke J. M. De BoerJeerasak ChobtangDioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.http://www.mdpi.com/1424-8220/11/12/11692/dioxinsbiosensorpolychlorinated biphenylsfood chain
collection DOAJ
language English
format Article
sources DOAJ
author Aize Kijlstra
Bastiaan G. Meerburg
Willem Haasnoot
Ron L. A. P. Hoogenboom
Imke J. M. De Boer
Jeerasak Chobtang
spellingShingle Aize Kijlstra
Bastiaan G. Meerburg
Willem Haasnoot
Ron L. A. P. Hoogenboom
Imke J. M. De Boer
Jeerasak Chobtang
The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain
Sensors
dioxins
biosensor
polychlorinated biphenyls
food chain
author_facet Aize Kijlstra
Bastiaan G. Meerburg
Willem Haasnoot
Ron L. A. P. Hoogenboom
Imke J. M. De Boer
Jeerasak Chobtang
author_sort Aize Kijlstra
title The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain
title_short The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain
title_full The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain
title_fullStr The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain
title_full_unstemmed The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain
title_sort need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2011-12-01
description Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.
topic dioxins
biosensor
polychlorinated biphenyls
food chain
url http://www.mdpi.com/1424-8220/11/12/11692/
work_keys_str_mv AT aizekijlstra theneedandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT bastiaangmeerburg theneedandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT willemhaasnoot theneedandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT ronlaphoogenboom theneedandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT imkejmdeboer theneedandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT jeerasakchobtang theneedandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT aizekijlstra needandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT bastiaangmeerburg needandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT willemhaasnoot needandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT ronlaphoogenboom needandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT imkejmdeboer needandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
AT jeerasakchobtang needandpotentialofbiosensorstodetectdioxinsanddioxinlikepolychlorinatedbiphenylsalongthemilkeggsandmeatfoodchain
_version_ 1725364911312207872