Latex microcapsules for morphine detection in human physiologic liquids

A new diagnostic test-system based on the polymer microsphere - bioligand was developed for qualitative and semiquantitative analysis of morphine in human physiologic liquids by the latex agglutination method. The new reliable and quick method of analysis enables detecting morphine in human urine wi...

Full description

Bibliographic Details
Main Authors: N. М. Solodukhina, Т. V. Abramenko, М. А. Myagkova, I. А. Gritskova
Format: Article
Language:Russian
Published: MIREA - Russian Technological University 2010-04-01
Series:Тонкие химические технологии
Subjects:
Online Access:https://www.finechem-mirea.ru/jour/article/view/998
id doaj-7d85ad435d8845c6a67a681cba67e36d
record_format Article
spelling doaj-7d85ad435d8845c6a67a681cba67e36d2021-07-28T13:23:53ZrusMIREA - Russian Technological UniversityТонкие химические технологии2410-65932686-75752010-04-01525558992Latex microcapsules for morphine detection in human physiologic liquidsN. М. Solodukhina0Т. V. Abramenko1М. А. Myagkova2I. А. Gritskova3M.V. Lomonosov Moscow State University of Fine Chemical Technologies, 86, Vernadskogo pr., Moscow 119571Институт физиологически активных веществ РАН, ЧерноголовкаИнститут физиологически активных веществ РАН, ЧерноголовкаM.V. Lomonosov Moscow State University of Fine Chemical Technologies, 86, Vernadskogo pr., Moscow 119571A new diagnostic test-system based on the polymer microsphere - bioligand was developed for qualitative and semiquantitative analysis of morphine in human physiologic liquids by the latex agglutination method. The new reliable and quick method of analysis enables detecting morphine in human urine within 3-5 minutes without using any laboratory devices.https://www.finechem-mirea.ru/jour/article/view/998latex agglutinationpolystyrene microspheresmorphinetechniques for diagnostics of opiates in human urine
collection DOAJ
language Russian
format Article
sources DOAJ
author N. М. Solodukhina
Т. V. Abramenko
М. А. Myagkova
I. А. Gritskova
spellingShingle N. М. Solodukhina
Т. V. Abramenko
М. А. Myagkova
I. А. Gritskova
Latex microcapsules for morphine detection in human physiologic liquids
Тонкие химические технологии
latex agglutination
polystyrene microspheres
morphine
techniques for diagnostics of opiates in human urine
author_facet N. М. Solodukhina
Т. V. Abramenko
М. А. Myagkova
I. А. Gritskova
author_sort N. М. Solodukhina
title Latex microcapsules for morphine detection in human physiologic liquids
title_short Latex microcapsules for morphine detection in human physiologic liquids
title_full Latex microcapsules for morphine detection in human physiologic liquids
title_fullStr Latex microcapsules for morphine detection in human physiologic liquids
title_full_unstemmed Latex microcapsules for morphine detection in human physiologic liquids
title_sort latex microcapsules for morphine detection in human physiologic liquids
publisher MIREA - Russian Technological University
series Тонкие химические технологии
issn 2410-6593
2686-7575
publishDate 2010-04-01
description A new diagnostic test-system based on the polymer microsphere - bioligand was developed for qualitative and semiquantitative analysis of morphine in human physiologic liquids by the latex agglutination method. The new reliable and quick method of analysis enables detecting morphine in human urine within 3-5 minutes without using any laboratory devices.
topic latex agglutination
polystyrene microspheres
morphine
techniques for diagnostics of opiates in human urine
url https://www.finechem-mirea.ru/jour/article/view/998
work_keys_str_mv AT nmsolodukhina latexmicrocapsulesformorphinedetectioninhumanphysiologicliquids
AT tvabramenko latexmicrocapsulesformorphinedetectioninhumanphysiologicliquids
AT mamyagkova latexmicrocapsulesformorphinedetectioninhumanphysiologicliquids
AT iagritskova latexmicrocapsulesformorphinedetectioninhumanphysiologicliquids
_version_ 1721275189778448384