TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER

Purpose. To show capabilities of topological models of three-phase, five-limb transformer to correctly represent transformer operation in regimes with high flux densities in the core. As a practically important example, time domain response of transformer subjected to geomagnetically induced current...

Full description

Bibliographic Details
Main Authors: S. E. Zirka, Y. I. Moroz, C. M. Arturi, D. Bonnman
Format: Article
Language:English
Published: Zaporozhye National Technical University 2018-02-01
Series:Elektrotehnìka ta Elektroenergetika
Subjects:
Online Access:http://ee.zntu.edu.ua/article/view/123291
id doaj-7dda3e427d964f818420a4bfd9803115
record_format Article
spelling doaj-7dda3e427d964f818420a4bfd98031152021-08-18T10:16:05ZengZaporozhye National Technical UniversityElektrotehnìka ta Elektroenergetika1607-67612521-62442018-02-0102182510.15588/1607-6761-2017-2-2123291TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMERS. E. Zirka0Y. I. Moroz1C. M. Arturi2D. Bonnman3Dnipro National UniversityDnipro National UniversityPolitechnico di MilanoABB AGPurpose. To show capabilities of topological models of three-phase, five-limb transformer to correctly represent transformer operation in regimes with high flux densities in the core. As a practically important example, time domain response of transformer subjected to geomagnetically induced currents (GIC) is analyzed and compared with results of a comprehensive field experiment.Methodology.  Transformer magnetic model, which takes into account geometry of the core and windings, is transformed in a dual electric equivalent scheme, whose transient is calculated by using EMTP-ATP. The results obtained demonstrate the importance of incorporating the positive and zero sequence impedances of power network.Findings. A simple and reliable model of five-limb transformer is proposed. It was found that the presence of the transformer tank can be effectively accounted for by linear inductances representing the paths of the off-core fluxes from yoke to yoke. The modeling of GIC events represented in the paper is the most accurate ever obtained for three-phase, five-leg transformers. The model is validated by close agreement of the predicted values and waveforms of the phase currents and reactive power with those measured in tests performed on two 400 MVA transformers connected back-to-back and to a 400 kV power network. Originality. It is shown that a simplified non-hysteresis model developed portrays the behavior of the of five-limb transformer under GIC condition with the same good accuracy as its hysteresis model. Both the transformer models are well grounded. So, the paper dispels some misconceptions about the influence of the hysteresis properties of the core material and tank in transient modeling of five-leg transformers.Practical value. The practical value and significance of the paper is caused by the fact that the model proposed is a simple and reliable tool for power system studies. The paper warns of using unnecessary complicated models whose parameters are difficult to be estimated by experiments or calculations.http://ee.zntu.edu.ua/article/view/123291five-limb transformertopological transient modelstransientsoff-core magnetic fluxescurrent waveformsreactive powerexperimental validationback-to-back transformer test
collection DOAJ
language English
format Article
sources DOAJ
author S. E. Zirka
Y. I. Moroz
C. M. Arturi
D. Bonnman
spellingShingle S. E. Zirka
Y. I. Moroz
C. M. Arturi
D. Bonnman
TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER
Elektrotehnìka ta Elektroenergetika
five-limb transformer
topological transient models
transients
off-core magnetic fluxes
current waveforms
reactive power
experimental validation
back-to-back transformer test
author_facet S. E. Zirka
Y. I. Moroz
C. M. Arturi
D. Bonnman
author_sort S. E. Zirka
title TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER
title_short TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER
title_full TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER
title_fullStr TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER
title_full_unstemmed TOPOLOGICAL TRANSIENT MODELS OF THREE-PHASE FIVE-LIMB TRANSFORMER
title_sort topological transient models of three-phase five-limb transformer
publisher Zaporozhye National Technical University
series Elektrotehnìka ta Elektroenergetika
issn 1607-6761
2521-6244
publishDate 2018-02-01
description Purpose. To show capabilities of topological models of three-phase, five-limb transformer to correctly represent transformer operation in regimes with high flux densities in the core. As a practically important example, time domain response of transformer subjected to geomagnetically induced currents (GIC) is analyzed and compared with results of a comprehensive field experiment.Methodology.  Transformer magnetic model, which takes into account geometry of the core and windings, is transformed in a dual electric equivalent scheme, whose transient is calculated by using EMTP-ATP. The results obtained demonstrate the importance of incorporating the positive and zero sequence impedances of power network.Findings. A simple and reliable model of five-limb transformer is proposed. It was found that the presence of the transformer tank can be effectively accounted for by linear inductances representing the paths of the off-core fluxes from yoke to yoke. The modeling of GIC events represented in the paper is the most accurate ever obtained for three-phase, five-leg transformers. The model is validated by close agreement of the predicted values and waveforms of the phase currents and reactive power with those measured in tests performed on two 400 MVA transformers connected back-to-back and to a 400 kV power network. Originality. It is shown that a simplified non-hysteresis model developed portrays the behavior of the of five-limb transformer under GIC condition with the same good accuracy as its hysteresis model. Both the transformer models are well grounded. So, the paper dispels some misconceptions about the influence of the hysteresis properties of the core material and tank in transient modeling of five-leg transformers.Practical value. The practical value and significance of the paper is caused by the fact that the model proposed is a simple and reliable tool for power system studies. The paper warns of using unnecessary complicated models whose parameters are difficult to be estimated by experiments or calculations.
topic five-limb transformer
topological transient models
transients
off-core magnetic fluxes
current waveforms
reactive power
experimental validation
back-to-back transformer test
url http://ee.zntu.edu.ua/article/view/123291
work_keys_str_mv AT sezirka topologicaltransientmodelsofthreephasefivelimbtransformer
AT yimoroz topologicaltransientmodelsofthreephasefivelimbtransformer
AT cmarturi topologicaltransientmodelsofthreephasefivelimbtransformer
AT dbonnman topologicaltransientmodelsofthreephasefivelimbtransformer
_version_ 1721203102625824768