Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study

Introduction: Pulpectomy is the treatment of choice for primary teeth with irreversible pulpitis or necrosis. Chemo-mechanical preparation is an important aspect of pulpectomy. Mechanical instrumentation can be accomplished by instrumentation with hand, rotary or reciprocating systems. Nickel-Titani...

Full description

Bibliographic Details
Main Authors: Farhin Katge, Sanjana Ghadge, Manohar Poojari, Khushboo Jain, Devendra Patil
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2019-07-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/12983/41425_CE[Ra1]_F(SL)_PF1(AJ_SHU)_PN(SL).pdf
id doaj-8044ec0d9185426280eb079478be0bb2
record_format Article
spelling doaj-8044ec0d9185426280eb079478be0bb22020-11-25T02:40:30ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2019-07-01137ZC06ZC0910.7860/JCDR/2019/41425.12983Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro StudyFarhin Katge0Sanjana Ghadge1Manohar Poojari2Khushboo Jain3Devendra Patil4Professor and Head, Department of Pedodontics and Preventive Dentistry, Terna Dental College, Navi Mumbai, Mahrashtra, India.Postgraduate Student, Department of Pedodontics and Preventive Dentistry, Terna Dental College, Navi Mumbai, Mahrashtra, India.Reader, Department of Pedodontics and Preventive Dentistry, Terna Dental College, Navi Mumbai, Mahrashtra, India.Postgraduate Student, Department of Pedodontics and Preventive Dentistry, Terna Dental College, Navi Mumbai, Mahrashtra, India.Lecturer, Department of Pedodontics and Preventive Dentistry, Terna Dental College, Navi Mumbai, Mahrashtra, India.Introduction: Pulpectomy is the treatment of choice for primary teeth with irreversible pulpitis or necrosis. Chemo-mechanical preparation is an important aspect of pulpectomy. Mechanical instrumentation can be accomplished by instrumentation with hand, rotary or reciprocating systems. Nickel-Titanium (NiTi) rotary files have inherent flexibility which preserves the original anatomy of root canals in primary teeth during instrumentation. Aim: To evaluate and compare the cleaning efficacy of two paediatric rotary files (Prime Pedo™, DXL-Pro™ with H files in root canals of primary molars. Materials and Methods: A total of 54 extracted primary maxillary and mandibular molars were selected for the study. The selected teeth had at least two-third of root length. Teeth with internal or external pathological root resorption or perforation in the furcation area were excluded from the study. Sixty intact root canals were selected for the study. India ink was injected in all the root canals using 30-gauge insulin syringe. The remaining traces of ink after instrumentation were evaluated for assessing the cleaning efficacy. The first set of root canals (n=20) were instrumented with Group I rotary files (Prime Pedo™). The second set of root canals (n=20) were instrumented with Group II (DXL-Pro™) rotary files and third set of root canals (n=20) were instrumented with H files. Teeth were decalcified and dehydrated. They were then cleared in methyl salicylate. The samples were observed under stereomicroscope at 10X magnification for residual ink at coronal, middle and apical third of root canal. The scores obtained were analysed using One-Way ANOVA test. Results: Prime Pedo (p<0.025) and DXL-Pro (p<0.012) files had better cleaning efficacy compared to H files at the coronal and apical third of root canals. Intergroup comparison between Prime Pedo and DXL-Pro showed no statistically significant difference. No significant difference could be found between three file systems at middle third of root canals. Conclusion: Paediatric rotary files had a better cleaning efficacy as compared to H files at coronal and apical third of root canals. However, at middle third, no difference in cleaning efficacy was found between two paediatric rotary files (Prime Pedo™, DXL-Pro™) and H files. Paediatric rotary files can be used as an alternative to conventional H files in routine paediatric endodontics for better instrumentation of root canals.https://jcdr.net/articles/PDF/12983/41425_CE[Ra1]_F(SL)_PF1(AJ_SHU)_PN(SL).pdfpaediatric endodonticspaediatric rotary filesprimary molarspulpectomy
collection DOAJ
language English
format Article
sources DOAJ
author Farhin Katge
Sanjana Ghadge
Manohar Poojari
Khushboo Jain
Devendra Patil
spellingShingle Farhin Katge
Sanjana Ghadge
Manohar Poojari
Khushboo Jain
Devendra Patil
Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study
Journal of Clinical and Diagnostic Research
paediatric endodontics
paediatric rotary files
primary molars
pulpectomy
author_facet Farhin Katge
Sanjana Ghadge
Manohar Poojari
Khushboo Jain
Devendra Patil
author_sort Farhin Katge
title Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study
title_short Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study
title_full Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study
title_fullStr Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study
title_full_unstemmed Comparative Evaluation of Cleaning Efficacy of Prime Pedo™ and DXL-Pro™ Pedo Rotary Files with Conventional H Files in Root Canals of Primary Teeth: An In Vitro Study
title_sort comparative evaluation of cleaning efficacy of prime pedo™ and dxl-pro™ pedo rotary files with conventional h files in root canals of primary teeth: an in vitro study
publisher JCDR Research and Publications Private Limited
series Journal of Clinical and Diagnostic Research
issn 2249-782X
0973-709X
publishDate 2019-07-01
description Introduction: Pulpectomy is the treatment of choice for primary teeth with irreversible pulpitis or necrosis. Chemo-mechanical preparation is an important aspect of pulpectomy. Mechanical instrumentation can be accomplished by instrumentation with hand, rotary or reciprocating systems. Nickel-Titanium (NiTi) rotary files have inherent flexibility which preserves the original anatomy of root canals in primary teeth during instrumentation. Aim: To evaluate and compare the cleaning efficacy of two paediatric rotary files (Prime Pedo™, DXL-Pro™ with H files in root canals of primary molars. Materials and Methods: A total of 54 extracted primary maxillary and mandibular molars were selected for the study. The selected teeth had at least two-third of root length. Teeth with internal or external pathological root resorption or perforation in the furcation area were excluded from the study. Sixty intact root canals were selected for the study. India ink was injected in all the root canals using 30-gauge insulin syringe. The remaining traces of ink after instrumentation were evaluated for assessing the cleaning efficacy. The first set of root canals (n=20) were instrumented with Group I rotary files (Prime Pedo™). The second set of root canals (n=20) were instrumented with Group II (DXL-Pro™) rotary files and third set of root canals (n=20) were instrumented with H files. Teeth were decalcified and dehydrated. They were then cleared in methyl salicylate. The samples were observed under stereomicroscope at 10X magnification for residual ink at coronal, middle and apical third of root canal. The scores obtained were analysed using One-Way ANOVA test. Results: Prime Pedo (p<0.025) and DXL-Pro (p<0.012) files had better cleaning efficacy compared to H files at the coronal and apical third of root canals. Intergroup comparison between Prime Pedo and DXL-Pro showed no statistically significant difference. No significant difference could be found between three file systems at middle third of root canals. Conclusion: Paediatric rotary files had a better cleaning efficacy as compared to H files at coronal and apical third of root canals. However, at middle third, no difference in cleaning efficacy was found between two paediatric rotary files (Prime Pedo™, DXL-Pro™) and H files. Paediatric rotary files can be used as an alternative to conventional H files in routine paediatric endodontics for better instrumentation of root canals.
topic paediatric endodontics
paediatric rotary files
primary molars
pulpectomy
url https://jcdr.net/articles/PDF/12983/41425_CE[Ra1]_F(SL)_PF1(AJ_SHU)_PN(SL).pdf
work_keys_str_mv AT farhinkatge comparativeevaluationofcleaningefficacyofprimepedoanddxlpropedorotaryfileswithconventionalhfilesinrootcanalsofprimaryteethaninvitrostudy
AT sanjanaghadge comparativeevaluationofcleaningefficacyofprimepedoanddxlpropedorotaryfileswithconventionalhfilesinrootcanalsofprimaryteethaninvitrostudy
AT manoharpoojari comparativeevaluationofcleaningefficacyofprimepedoanddxlpropedorotaryfileswithconventionalhfilesinrootcanalsofprimaryteethaninvitrostudy
AT khushboojain comparativeevaluationofcleaningefficacyofprimepedoanddxlpropedorotaryfileswithconventionalhfilesinrootcanalsofprimaryteethaninvitrostudy
AT devendrapatil comparativeevaluationofcleaningefficacyofprimepedoanddxlpropedorotaryfileswithconventionalhfilesinrootcanalsofprimaryteethaninvitrostudy
_version_ 1724781241889193984