Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation

OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selec...

Full description

Bibliographic Details
Main Authors: Marcel M. Farret, Eduardo Martinelli de Lima, Eduardo Gonçalves Mota, Hugo Mitsuo S. Oshima, Gabriela Maguilnik, Patrícia Alves Scheid
Format: Article
Language:English
Published: Dental Press Editora 2012-12-01
Series:Dental Press Journal of Orthodontics
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000600027
id doaj-825aceaea1524bdc91b69eddbb94953f
record_format Article
spelling doaj-825aceaea1524bdc91b69eddbb94953f2020-11-24T21:18:31ZengDental Press Editora Dental Press Journal of Orthodontics 2176-94512177-67092012-12-01176154159Assessment of the mechanical properties of glass ionomer cements for orthodontic cementationMarcel M. FarretEduardo Martinelli de LimaEduardo Gonçalves MotaHugo Mitsuo S. OshimaGabriela MaguilnikPatrícia Alves ScheidOBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.<br>OBJETIVO: avaliar as propriedades mecânicas de três cimentos de ionômero de vidro (CIVs) utilizados para cimentação de anéis ortodônticos. MÉTODOS: foram utilizados dois CIVs convencionais (Ketac Cem Easy mix/3M-ESPE e Meron/Voco) e um CIV modificado por resina (Multi-Cure Glass ionomer/3M-Unitek). Para os testes de resistência à compressão e tração diametral, foram confeccionados 12 corpos de prova de cada material. Para os testes de microdureza, foram confeccionados 15 corpos de prova de cada material; para os testes de resistência de união ao cisalhamento, foram utilizados 45 dentes bovinos incluídos em resina acrílica, sobre os quais foi cimentada uma lâmina de anel ortodôntico com braquete soldado a ela para a realização dos ensaios. Para os testes de compressão, tração diametral e cisalhamento, foi utilizada uma máquina universal de ensaios a uma velocidade de 1mm/min; para os testes de microdureza Vickers, foi utilizado um microdurômetro com 200g de carga durante 15 segundos. Os resultados foram submetidos à análise estatística ANOVA, complementada pelo teste de Tukey ao nível de significância de 5%. RESULTADOS: os resultados demonstraram que o Multi-Cure Glass Ionomer apresentou resistência à tração diametral significativamente maior (p < 0,01) e maior resistência à compressão (p = 0,08) em relação aos CIVs convencionais. Além disso, o Ketac Cem apresentou microdureza significativamente maior que os demais materiais (p < 0,01). CONCLUSÃO: o CIV modificado por resina apresentou propriedades mecânicas superiores às dos CIVs convencionais, que, por sua vez, apresentaram poucas diferenças entre si.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000600027Cimentos de ionômero de vidroMateriais dentáriosCimentaçãoOrtodontiaGlass ionomer cementsDental materialCementationOrthodontics
collection DOAJ
language English
format Article
sources DOAJ
author Marcel M. Farret
Eduardo Martinelli de Lima
Eduardo Gonçalves Mota
Hugo Mitsuo S. Oshima
Gabriela Maguilnik
Patrícia Alves Scheid
spellingShingle Marcel M. Farret
Eduardo Martinelli de Lima
Eduardo Gonçalves Mota
Hugo Mitsuo S. Oshima
Gabriela Maguilnik
Patrícia Alves Scheid
Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
Dental Press Journal of Orthodontics
Cimentos de ionômero de vidro
Materiais dentários
Cimentação
Ortodontia
Glass ionomer cements
Dental material
Cementation
Orthodontics
author_facet Marcel M. Farret
Eduardo Martinelli de Lima
Eduardo Gonçalves Mota
Hugo Mitsuo S. Oshima
Gabriela Maguilnik
Patrícia Alves Scheid
author_sort Marcel M. Farret
title Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
title_short Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
title_full Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
title_fullStr Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
title_full_unstemmed Assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
title_sort assessment of the mechanical properties of glass ionomer cements for orthodontic cementation
publisher Dental Press Editora
series Dental Press Journal of Orthodontics
issn 2176-9451
2177-6709
publishDate 2012-12-01
description OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.<br>OBJETIVO: avaliar as propriedades mecânicas de três cimentos de ionômero de vidro (CIVs) utilizados para cimentação de anéis ortodônticos. MÉTODOS: foram utilizados dois CIVs convencionais (Ketac Cem Easy mix/3M-ESPE e Meron/Voco) e um CIV modificado por resina (Multi-Cure Glass ionomer/3M-Unitek). Para os testes de resistência à compressão e tração diametral, foram confeccionados 12 corpos de prova de cada material. Para os testes de microdureza, foram confeccionados 15 corpos de prova de cada material; para os testes de resistência de união ao cisalhamento, foram utilizados 45 dentes bovinos incluídos em resina acrílica, sobre os quais foi cimentada uma lâmina de anel ortodôntico com braquete soldado a ela para a realização dos ensaios. Para os testes de compressão, tração diametral e cisalhamento, foi utilizada uma máquina universal de ensaios a uma velocidade de 1mm/min; para os testes de microdureza Vickers, foi utilizado um microdurômetro com 200g de carga durante 15 segundos. Os resultados foram submetidos à análise estatística ANOVA, complementada pelo teste de Tukey ao nível de significância de 5%. RESULTADOS: os resultados demonstraram que o Multi-Cure Glass Ionomer apresentou resistência à tração diametral significativamente maior (p < 0,01) e maior resistência à compressão (p = 0,08) em relação aos CIVs convencionais. Além disso, o Ketac Cem apresentou microdureza significativamente maior que os demais materiais (p < 0,01). CONCLUSÃO: o CIV modificado por resina apresentou propriedades mecânicas superiores às dos CIVs convencionais, que, por sua vez, apresentaram poucas diferenças entre si.
topic Cimentos de ionômero de vidro
Materiais dentários
Cimentação
Ortodontia
Glass ionomer cements
Dental material
Cementation
Orthodontics
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000600027
work_keys_str_mv AT marcelmfarret assessmentofthemechanicalpropertiesofglassionomercementsfororthodonticcementation
AT eduardomartinellidelima assessmentofthemechanicalpropertiesofglassionomercementsfororthodonticcementation
AT eduardogoncalvesmota assessmentofthemechanicalpropertiesofglassionomercementsfororthodonticcementation
AT hugomitsuososhima assessmentofthemechanicalpropertiesofglassionomercementsfororthodonticcementation
AT gabrielamaguilnik assessmentofthemechanicalpropertiesofglassionomercementsfororthodonticcementation
AT patriciaalvesscheid assessmentofthemechanicalpropertiesofglassionomercementsfororthodonticcementation
_version_ 1726008641089175552