An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams

Background: In this study, a method for linear attenuation coefficient calculation was introduced. Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The ca...

Full description

Bibliographic Details
Main Authors: Seif F., Tahmasebi-Birgani M. J., Bayatiani M. R.
Format: Article
Language:English
Published: Shiraz University of Medical Sciences 2017-09-01
Series:Journal of Biomedical Physics and Engineering
Subjects:
Online Access:http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/493/307
id doaj-8276fdd8f71341bfba12358b295ec894
record_format Article
spelling doaj-8276fdd8f71341bfba12358b295ec8942020-11-25T00:27:59ZengShiraz University of Medical SciencesJournal of Biomedical Physics and Engineering2251-72002251-72002017-09-0172225232An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon BeamsSeif F.0Tahmasebi-Birgani M. J.1Bayatiani M. R.2Assistant professor, Department of Medical Physics and Radiotherapy, Arak University of Medical Sciences, Arak, Iran Professor, Department of Medical Physics and Radiotherapy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IranAssistant professor, Department of Medical Physics and Radiotherapy, Arak University of Medical Sciences, Arak, Iran Background: In this study, a method for linear attenuation coefficient calculation was introduced. Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. Results: The values of calculated linear attenuation coefficient with this new method are in acceptable range. Also, the linear attenuation coefficient decreases slightly as the thickness of attenuating filter (Cerrobend or mercury) increased, so the procedure of linear attenuation coefficient variation is in agreement with other documents. The results showed that the attenuation ability of mercury was about 1.44 times more than Cerrobend. Conclusion: The method that was introduced in this study for linear attenuation coefficient calculation is general enough to treat beam modifiers with any shape or material by using the same formalism; however, calculating was made only for mercury and Cerrobend attenuator. On the other hand, it seems that this method is suitable for high energy shields or protector designing. http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/493/307CerrobendLinear Attenuation CoefficientEnergy Spectral
collection DOAJ
language English
format Article
sources DOAJ
author Seif F.
Tahmasebi-Birgani M. J.
Bayatiani M. R.
spellingShingle Seif F.
Tahmasebi-Birgani M. J.
Bayatiani M. R.
An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
Journal of Biomedical Physics and Engineering
Cerrobend
Linear Attenuation Coefficient
Energy Spectral
author_facet Seif F.
Tahmasebi-Birgani M. J.
Bayatiani M. R.
author_sort Seif F.
title An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
title_short An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
title_full An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
title_fullStr An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
title_full_unstemmed An Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
title_sort analytical-empirical calculation of linear attenuation coefficient of megavoltage photon beams
publisher Shiraz University of Medical Sciences
series Journal of Biomedical Physics and Engineering
issn 2251-7200
2251-7200
publishDate 2017-09-01
description Background: In this study, a method for linear attenuation coefficient calculation was introduced. Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. Results: The values of calculated linear attenuation coefficient with this new method are in acceptable range. Also, the linear attenuation coefficient decreases slightly as the thickness of attenuating filter (Cerrobend or mercury) increased, so the procedure of linear attenuation coefficient variation is in agreement with other documents. The results showed that the attenuation ability of mercury was about 1.44 times more than Cerrobend. Conclusion: The method that was introduced in this study for linear attenuation coefficient calculation is general enough to treat beam modifiers with any shape or material by using the same formalism; however, calculating was made only for mercury and Cerrobend attenuator. On the other hand, it seems that this method is suitable for high energy shields or protector designing.
topic Cerrobend
Linear Attenuation Coefficient
Energy Spectral
url http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/493/307
work_keys_str_mv AT seiff ananalyticalempiricalcalculationoflinearattenuationcoefficientofmegavoltagephotonbeams
AT tahmasebibirganimj ananalyticalempiricalcalculationoflinearattenuationcoefficientofmegavoltagephotonbeams
AT bayatianimr ananalyticalempiricalcalculationoflinearattenuationcoefficientofmegavoltagephotonbeams
AT seiff analyticalempiricalcalculationoflinearattenuationcoefficientofmegavoltagephotonbeams
AT tahmasebibirganimj analyticalempiricalcalculationoflinearattenuationcoefficientofmegavoltagephotonbeams
AT bayatianimr analyticalempiricalcalculationoflinearattenuationcoefficientofmegavoltagephotonbeams
_version_ 1725337409843888128