Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows

Aggregation of red blood cells (RBCs) varies substantially depending on changes of several factors such as hematocrit, membrane deformability, and plasma proteins. Among these factors, hematocrit has a strong influence on the aggregation of RBCs. Thus, while measuring RBCs aggregation, it is necessa...

Full description

Bibliographic Details
Main Author: Yang Jun Kang
Format: Article
Language:English
Published: MDPI AG 2019-08-01
Series:Micromachines
Subjects:
Online Access:https://www.mdpi.com/2072-666X/10/9/577
id doaj-82c00e6d11714b6d9c3c2a4f0b45e9ae
record_format Article
spelling doaj-82c00e6d11714b6d9c3c2a4f0b45e9ae2020-11-25T01:18:50ZengMDPI AGMicromachines2072-666X2019-08-0110957710.3390/mi10090577mi10090577Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood FlowsYang Jun Kang0Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, KoreaAggregation of red blood cells (RBCs) varies substantially depending on changes of several factors such as hematocrit, membrane deformability, and plasma proteins. Among these factors, hematocrit has a strong influence on the aggregation of RBCs. Thus, while measuring RBCs aggregation, it is necessary to monitor hematocrit or, additionally, the effect of hematocrit (i.e., blood viscosity or pressure). In this study, the sequential measurement method of pressure and RBC aggregation is proposed by quantifying blood flow (i.e., velocity and image intensity) through a microfluidic device, in which an air-compressed syringe (ACS) is used to control the sample injection. The microfluidic device used is composed of two channels (pressure channel (PC), and blood channel (BC)), an inlet, and an outlet. A single ACS (i.e., air suction = 0.4 mL, blood suction = 0.4 mL, and air compression = 0.3 mL) is employed to supply blood into the microfluidic channel. At an initial time (<i>t</i> &lt; 10 s), the pressure index (<i>PI</i>) is evaluated by analyzing the intensity of microscopy images of blood samples collected inside PC. During blood delivery with ACS, shear rates of blood flows vary continuously over time. After a certain amount of time has elapsed (<i>t</i> &gt; 30 s), two RBC aggregation indices (i.e., <i>S<sub>EAI</sub></i>: without information on shear rate, and erythrocyte aggregation index (<i>EAI</i>): with information on shear rate) are quantified by analyzing the image intensity and velocity field of blood flow in BC. According to experimental results, <i>PI</i> depends significantly on the characteristics of the blood samples (i.e., hematocrit or base solutions) and can be used effectively as an alternative to blood viscosity. In addition, <i>S<sub>EAI</sub></i> and <i>EAI</i> also depend significantly on the degree of RBC aggregation. In conclusion, on the basis of three indices (two RBC aggregation indices and pressure index), the proposed method is capable of measuring RBCs aggregation consistently using a microfluidic device.https://www.mdpi.com/2072-666X/10/9/577RBCs aggregationblood pressureACS (air-compressed syringe)microfluidic devicecontinuous varying flow rates
collection DOAJ
language English
format Article
sources DOAJ
author Yang Jun Kang
spellingShingle Yang Jun Kang
Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows
Micromachines
RBCs aggregation
blood pressure
ACS (air-compressed syringe)
microfluidic device
continuous varying flow rates
author_facet Yang Jun Kang
author_sort Yang Jun Kang
title Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows
title_short Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows
title_full Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows
title_fullStr Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows
title_full_unstemmed Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows
title_sort microfluidic-based biosensor for sequential measurement of blood pressure and rbc aggregation over continuously varying blood flows
publisher MDPI AG
series Micromachines
issn 2072-666X
publishDate 2019-08-01
description Aggregation of red blood cells (RBCs) varies substantially depending on changes of several factors such as hematocrit, membrane deformability, and plasma proteins. Among these factors, hematocrit has a strong influence on the aggregation of RBCs. Thus, while measuring RBCs aggregation, it is necessary to monitor hematocrit or, additionally, the effect of hematocrit (i.e., blood viscosity or pressure). In this study, the sequential measurement method of pressure and RBC aggregation is proposed by quantifying blood flow (i.e., velocity and image intensity) through a microfluidic device, in which an air-compressed syringe (ACS) is used to control the sample injection. The microfluidic device used is composed of two channels (pressure channel (PC), and blood channel (BC)), an inlet, and an outlet. A single ACS (i.e., air suction = 0.4 mL, blood suction = 0.4 mL, and air compression = 0.3 mL) is employed to supply blood into the microfluidic channel. At an initial time (<i>t</i> &lt; 10 s), the pressure index (<i>PI</i>) is evaluated by analyzing the intensity of microscopy images of blood samples collected inside PC. During blood delivery with ACS, shear rates of blood flows vary continuously over time. After a certain amount of time has elapsed (<i>t</i> &gt; 30 s), two RBC aggregation indices (i.e., <i>S<sub>EAI</sub></i>: without information on shear rate, and erythrocyte aggregation index (<i>EAI</i>): with information on shear rate) are quantified by analyzing the image intensity and velocity field of blood flow in BC. According to experimental results, <i>PI</i> depends significantly on the characteristics of the blood samples (i.e., hematocrit or base solutions) and can be used effectively as an alternative to blood viscosity. In addition, <i>S<sub>EAI</sub></i> and <i>EAI</i> also depend significantly on the degree of RBC aggregation. In conclusion, on the basis of three indices (two RBC aggregation indices and pressure index), the proposed method is capable of measuring RBCs aggregation consistently using a microfluidic device.
topic RBCs aggregation
blood pressure
ACS (air-compressed syringe)
microfluidic device
continuous varying flow rates
url https://www.mdpi.com/2072-666X/10/9/577
work_keys_str_mv AT yangjunkang microfluidicbasedbiosensorforsequentialmeasurementofbloodpressureandrbcaggregationovercontinuouslyvaryingbloodflows
_version_ 1725140087943987200