Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples

In this study, the electrochemical behaviors of cephalexin and cefazoline on disposable pencil graphite electrode were investigated in phosphate buffer at pH of 4.5 to 6.0 by differential pulse voltammetry. Sample analysis was performed in phosphate buffer at the optimum medium determined for each...

Full description

Bibliographic Details
Main Authors: Sabriye Perçin Özkorucuklu, Besnik Uka, Gizem Yıldırım Baştemur
Format: Article
Language:English
Published: Turkish Chemical Society 2019-06-01
Series:Journal of the Turkish Chemical Society, Section A: Chemistry
Subjects:
Online Access:https://dergipark.org.tr/jotcsa/issue/43285/469028
id doaj-82e18e0ca4bb4135afa208720afa45f9
record_format Article
spelling doaj-82e18e0ca4bb4135afa208720afa45f92020-11-25T00:35:15ZengTurkish Chemical SocietyJournal of the Turkish Chemical Society, Section A: Chemistry2149-01202019-06-016221722410.18596/jotcsa.469028Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological SamplesSabriye Perçin ÖzkorucukluBesnik Uka Gizem Yıldırım Baştemur In this study, the electrochemical behaviors of cephalexin and cefazoline on disposable pencil graphite electrode were investigated in phosphate buffer at pH of 4.5 to 6.0 by differential pulse voltammetry. Sample analysis was performed in phosphate buffer at the optimum medium determined for each sample. Validation parameters were studied to show the correctness, sensitivity, and consistency of the method developed for the cephalosporins. It was concluded that disposable pencil graphite electrode could be used effectively in the determination of cephalosporins. The limits of detection (S/N=3) were found to be 0.115 mM and 0.303 mM, for cephalexin and cefazoline, respectively. The analysis of these compounds in pharmaceutical formulations and biological samples was carried out at defined optimum conditions. The recovery values were around 100%. https://dergipark.org.tr/jotcsa/issue/43285/469028electrochemical biosensorspencil graphite electrodevoltammetric methodsBeta-lactam antibiotics
collection DOAJ
language English
format Article
sources DOAJ
author Sabriye Perçin Özkorucuklu
Besnik Uka
Gizem Yıldırım Baştemur
spellingShingle Sabriye Perçin Özkorucuklu
Besnik Uka
Gizem Yıldırım Baştemur
Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples
Journal of the Turkish Chemical Society, Section A: Chemistry
electrochemical biosensors
pencil graphite electrode
voltammetric methods
Beta-lactam antibiotics
author_facet Sabriye Perçin Özkorucuklu
Besnik Uka
Gizem Yıldırım Baştemur
author_sort Sabriye Perçin Özkorucuklu
title Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples
title_short Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples
title_full Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples
title_fullStr Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples
title_full_unstemmed Voltammetric Analysis of Cephalexin and Cefazoline in Pharmaceutical Formulation and Biological Samples
title_sort voltammetric analysis of cephalexin and cefazoline in pharmaceutical formulation and biological samples
publisher Turkish Chemical Society
series Journal of the Turkish Chemical Society, Section A: Chemistry
issn 2149-0120
publishDate 2019-06-01
description In this study, the electrochemical behaviors of cephalexin and cefazoline on disposable pencil graphite electrode were investigated in phosphate buffer at pH of 4.5 to 6.0 by differential pulse voltammetry. Sample analysis was performed in phosphate buffer at the optimum medium determined for each sample. Validation parameters were studied to show the correctness, sensitivity, and consistency of the method developed for the cephalosporins. It was concluded that disposable pencil graphite electrode could be used effectively in the determination of cephalosporins. The limits of detection (S/N=3) were found to be 0.115 mM and 0.303 mM, for cephalexin and cefazoline, respectively. The analysis of these compounds in pharmaceutical formulations and biological samples was carried out at defined optimum conditions. The recovery values were around 100%.
topic electrochemical biosensors
pencil graphite electrode
voltammetric methods
Beta-lactam antibiotics
url https://dergipark.org.tr/jotcsa/issue/43285/469028
work_keys_str_mv AT sabriyepercinozkorucuklu voltammetricanalysisofcephalexinandcefazolineinpharmaceuticalformulationandbiologicalsamples
AT besnikuka voltammetricanalysisofcephalexinandcefazolineinpharmaceuticalformulationandbiologicalsamples
AT gizemyıldırımbastemur voltammetricanalysisofcephalexinandcefazolineinpharmaceuticalformulationandbiologicalsamples
_version_ 1725309477612158976