An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting

The research has been carried out on the microbial hazards by using contaminated surgical instruments. In the operating room medical devices that have contact with sterile body tissues or fluids are considered as dangerous surgical tools. These surgical tools should be sterile when used because any...

Full description

Bibliographic Details
Main Authors: Madiha Saleem, Afsana Aslam
Format: Article
Language:English
Published: Jinnah University for Women 2017-05-01
Series:RADS Journal of Biological Research & Applied Science
Subjects:
Online Access:http://jbas.juw.edu.pk/index.php/JBAS/article/view/85
id doaj-8337b523510845b7b1d47df058bdedb4
record_format Article
spelling doaj-8337b523510845b7b1d47df058bdedb42020-11-25T00:28:53ZengJinnah University for WomenRADS Journal of Biological Research & Applied Science2305-87222521-85732017-05-018185An Exploratory Study of Contamination of Surgical Equipment’s in Hospital SettingMadiha Saleem0Afsana Aslam1Jinnah University for Women, Karachi Pakistan.Jinnah University for Women, Karachi Pakistan. The research has been carried out on the microbial hazards by using contaminated surgical instruments. In the operating room medical devices that have contact with sterile body tissues or fluids are considered as dangerous surgical tools. These surgical tools should be sterile when used because any microbial contamination could result in disease transmission and would leads to high number of Surgical Site Infections (SSI). The aim of this study is to establish the possible presence of known bacterial pathogens on surgical instruments in hospital settings, and to evaluate their antibiotic susceptibility profile. For this purpose a comparative research was conducted; the 40 samples were collected from instruments at the start and end of the procedure with the sterile cotton swabs; from the Gynea department, Abbasi Shaheed Hospital. These samples were cultured on the selective and differential media and incubated at 37°C for 24hr. Next day, these samples were processed and identified in Microbiology laboratory as per standard microbiological techniques; including the microscopy, biochemical tests, enzymes test and other culture characterizations test. The isolated microorganisms include E.coli, Staph aureus, Staph. saprophyticus, Strep viridians, Strep. bovis, Bacillus subtilis, and Pseudomonas spp. These microorganism were isolated from both autoclaved and non-autoclaved pre and post-operative surgical instruments respectively. Antibiotic susceptibility test was carried out by Kirby Bauer Method. Meropenum found to be the most effective against E.coli, Gentamycin and Novobiocin shows activity against S.aureus, Erythromycin also give zone of inhibition against S.bovis, Vancomycin shows activity against S.viridans, where Cephalenin and Ampicillin were also found to be effective against S. saprophyticus. Surgical instruments should be regarded as a possible source of nosocomial infection s since bacteria from them can be carried from the hands of theatre personnel to the patient undergoing surgery or through re-dispersed bacteria from surfaces during surgery. Therefore surgical procedure to prevent cross contamination instruments are sterilized and decontaminated. There has been advance in Surgical Site Infection (SSI) control practices which involves improved operating room ventilation, sterilization methods, surgical methods and availability of antimicrobial prophylaxis. http://jbas.juw.edu.pk/index.php/JBAS/article/view/85perioperativeSurgical site infection (SSI)sterilizationbioburden
collection DOAJ
language English
format Article
sources DOAJ
author Madiha Saleem
Afsana Aslam
spellingShingle Madiha Saleem
Afsana Aslam
An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting
RADS Journal of Biological Research & Applied Science
perioperative
Surgical site infection (SSI)
sterilization
bioburden
author_facet Madiha Saleem
Afsana Aslam
author_sort Madiha Saleem
title An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting
title_short An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting
title_full An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting
title_fullStr An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting
title_full_unstemmed An Exploratory Study of Contamination of Surgical Equipment’s in Hospital Setting
title_sort exploratory study of contamination of surgical equipment’s in hospital setting
publisher Jinnah University for Women
series RADS Journal of Biological Research & Applied Science
issn 2305-8722
2521-8573
publishDate 2017-05-01
description The research has been carried out on the microbial hazards by using contaminated surgical instruments. In the operating room medical devices that have contact with sterile body tissues or fluids are considered as dangerous surgical tools. These surgical tools should be sterile when used because any microbial contamination could result in disease transmission and would leads to high number of Surgical Site Infections (SSI). The aim of this study is to establish the possible presence of known bacterial pathogens on surgical instruments in hospital settings, and to evaluate their antibiotic susceptibility profile. For this purpose a comparative research was conducted; the 40 samples were collected from instruments at the start and end of the procedure with the sterile cotton swabs; from the Gynea department, Abbasi Shaheed Hospital. These samples were cultured on the selective and differential media and incubated at 37°C for 24hr. Next day, these samples were processed and identified in Microbiology laboratory as per standard microbiological techniques; including the microscopy, biochemical tests, enzymes test and other culture characterizations test. The isolated microorganisms include E.coli, Staph aureus, Staph. saprophyticus, Strep viridians, Strep. bovis, Bacillus subtilis, and Pseudomonas spp. These microorganism were isolated from both autoclaved and non-autoclaved pre and post-operative surgical instruments respectively. Antibiotic susceptibility test was carried out by Kirby Bauer Method. Meropenum found to be the most effective against E.coli, Gentamycin and Novobiocin shows activity against S.aureus, Erythromycin also give zone of inhibition against S.bovis, Vancomycin shows activity against S.viridans, where Cephalenin and Ampicillin were also found to be effective against S. saprophyticus. Surgical instruments should be regarded as a possible source of nosocomial infection s since bacteria from them can be carried from the hands of theatre personnel to the patient undergoing surgery or through re-dispersed bacteria from surfaces during surgery. Therefore surgical procedure to prevent cross contamination instruments are sterilized and decontaminated. There has been advance in Surgical Site Infection (SSI) control practices which involves improved operating room ventilation, sterilization methods, surgical methods and availability of antimicrobial prophylaxis.
topic perioperative
Surgical site infection (SSI)
sterilization
bioburden
url http://jbas.juw.edu.pk/index.php/JBAS/article/view/85
work_keys_str_mv AT madihasaleem anexploratorystudyofcontaminationofsurgicalequipmentasinhospitalsetting
AT afsanaaslam anexploratorystudyofcontaminationofsurgicalequipmentasinhospitalsetting
AT madihasaleem exploratorystudyofcontaminationofsurgicalequipmentasinhospitalsetting
AT afsanaaslam exploratorystudyofcontaminationofsurgicalequipmentasinhospitalsetting
_version_ 1725333769423945728