Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes
Measuring the radial collision force between the steam generator tube (SGT) and the tube support plate (TSP) is essential to assess the fretting damage of the SGT. In order to measure the radial collision force, a novel miniaturized force sensor based on fiber Fabry-Perot (F-P) was designed, and the...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2017-12-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/17/12/2899 |
id |
doaj-835ad6f3d091465c979777cc99c7b679 |
---|---|
record_format |
Article |
spelling |
doaj-835ad6f3d091465c979777cc99c7b6792020-11-24T21:53:03ZengMDPI AGSensors1424-82202017-12-011712289910.3390/s17122899s17122899Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator TubesPeijian Huang0Ning Wang1Junying Li2Yong Zhu3Jie Zhang4The Key Laboratory of Optoelectronic Technology & System (Ministry of Education), Chongqing University, Chongqing 400044, ChinaThe Key Laboratory of Optoelectronic Technology & System (Ministry of Education), Chongqing University, Chongqing 400044, ChinaThe Key Laboratory of Optoelectronic Technology & System (Ministry of Education), Chongqing University, Chongqing 400044, ChinaThe Key Laboratory of Optoelectronic Technology & System (Ministry of Education), Chongqing University, Chongqing 400044, ChinaThe Key Laboratory of Optoelectronic Technology & System (Ministry of Education), Chongqing University, Chongqing 400044, ChinaMeasuring the radial collision force between the steam generator tube (SGT) and the tube support plate (TSP) is essential to assess the fretting damage of the SGT. In order to measure the radial collision force, a novel miniaturized force sensor based on fiber Fabry-Perot (F-P) was designed, and the principle and characteristics of the sensor were analyzed in detail. Then, the F-P force sensor was successfully fabricated and calibrated, and the overall dimensions of the encapsulated fiber F-P sensor were 17 mm × 5 mm × 3 mm (L × W × H). The sensor works well in humid, high pressure (10 MPa), high temperature (350 °C), and vibration (40 kHz) environments. Finally, the F-P force sensors were installed in a 1:1 steam generator test loop, and the radial collision force signals between the SGT and the TSP were obtained. The experiments indicated that the F-P sensor with small volume and high performance could help in assessing the fretting damage of the steam generator tubes.https://www.mdpi.com/1424-8220/17/12/2899fiber optics sensorsteam generator tubefretting damagecollision force measurement |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Peijian Huang Ning Wang Junying Li Yong Zhu Jie Zhang |
spellingShingle |
Peijian Huang Ning Wang Junying Li Yong Zhu Jie Zhang Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes Sensors fiber optics sensor steam generator tube fretting damage collision force measurement |
author_facet |
Peijian Huang Ning Wang Junying Li Yong Zhu Jie Zhang |
author_sort |
Peijian Huang |
title |
Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes |
title_short |
Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes |
title_full |
Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes |
title_fullStr |
Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes |
title_full_unstemmed |
Fiber Fabry-Perot Force Sensor with Small Volume and High Performance for Assessing Fretting Damage of Steam Generator Tubes |
title_sort |
fiber fabry-perot force sensor with small volume and high performance for assessing fretting damage of steam generator tubes |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2017-12-01 |
description |
Measuring the radial collision force between the steam generator tube (SGT) and the tube support plate (TSP) is essential to assess the fretting damage of the SGT. In order to measure the radial collision force, a novel miniaturized force sensor based on fiber Fabry-Perot (F-P) was designed, and the principle and characteristics of the sensor were analyzed in detail. Then, the F-P force sensor was successfully fabricated and calibrated, and the overall dimensions of the encapsulated fiber F-P sensor were 17 mm × 5 mm × 3 mm (L × W × H). The sensor works well in humid, high pressure (10 MPa), high temperature (350 °C), and vibration (40 kHz) environments. Finally, the F-P force sensors were installed in a 1:1 steam generator test loop, and the radial collision force signals between the SGT and the TSP were obtained. The experiments indicated that the F-P sensor with small volume and high performance could help in assessing the fretting damage of the steam generator tubes. |
topic |
fiber optics sensor steam generator tube fretting damage collision force measurement |
url |
https://www.mdpi.com/1424-8220/17/12/2899 |
work_keys_str_mv |
AT peijianhuang fiberfabryperotforcesensorwithsmallvolumeandhighperformanceforassessingfrettingdamageofsteamgeneratortubes AT ningwang fiberfabryperotforcesensorwithsmallvolumeandhighperformanceforassessingfrettingdamageofsteamgeneratortubes AT junyingli fiberfabryperotforcesensorwithsmallvolumeandhighperformanceforassessingfrettingdamageofsteamgeneratortubes AT yongzhu fiberfabryperotforcesensorwithsmallvolumeandhighperformanceforassessingfrettingdamageofsteamgeneratortubes AT jiezhang fiberfabryperotforcesensorwithsmallvolumeandhighperformanceforassessingfrettingdamageofsteamgeneratortubes |
_version_ |
1725873192972582912 |