TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS
The present paper deals with experimental testing of the readability of RFID transponders in the sputtered magnesite dust layer under different conditions. In the first part of the article describes the measurement and the used.equipment. The second part includes the creation of experimental model w...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
4S go, s.r.o.
2016-03-01
|
Series: | Acta Tecnología |
Subjects: | |
Online Access: | http://www.actatecnologia.eu/issues/2016/I_2016_02_Balog_Mindas_Szilagyi_Duplakova_Knapcikova.pdf |
id |
doaj-83ba9e6fcffe41fb9732769b8da35565 |
---|---|
record_format |
Article |
spelling |
doaj-83ba9e6fcffe41fb9732769b8da355652020-11-25T01:20:34Zeng4S go, s.r.o.Acta Tecnología2453-675X2016-03-012171010.22306/atec.v2i1.8TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERSMichal Balog0Miroslav Mindas1Erik Szilagyi2Darina Duplakova3Lucia Knapcikova4Technical University of KosiceTechnical University of KosiceTechnical University of KosiceTechnical University of KosiceTechnical University of KosiceThe present paper deals with experimental testing of the readability of RFID transponders in the sputtered magnesite dust layer under different conditions. In the first part of the article describes the measurement and the used.equipment. The second part includes the creation of experimental model with a subsequent evaluation of measurements for the purposes of carrying out verification of the applicability of the selected RFID transponders in the circumstances. In conclusion, the publication is evaluated the progress of the experiment and the results of measurements determining the environmental conditions and meets the requirements of the application.http://www.actatecnologia.eu/issues/2016/I_2016_02_Balog_Mindas_Szilagyi_Duplakova_Knapcikova.pdfrfid transpondermagnesite dustmeasuremnt |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Michal Balog Miroslav Mindas Erik Szilagyi Darina Duplakova Lucia Knapcikova |
spellingShingle |
Michal Balog Miroslav Mindas Erik Szilagyi Darina Duplakova Lucia Knapcikova TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS Acta Tecnología rfid transponder magnesite dust measuremnt |
author_facet |
Michal Balog Miroslav Mindas Erik Szilagyi Darina Duplakova Lucia Knapcikova |
author_sort |
Michal Balog |
title |
TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS |
title_short |
TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS |
title_full |
TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS |
title_fullStr |
TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS |
title_full_unstemmed |
TECHNICAL MEASUREMENT AND ANALYSIS OF THE IMPACT OF MAGNESITE DEPOSIT OF DUST ON THE READABILITY OF RFID TRANSPONDERS |
title_sort |
technical measurement and analysis of the impact of magnesite deposit of dust on the readability of rfid transponders |
publisher |
4S go, s.r.o. |
series |
Acta Tecnología |
issn |
2453-675X |
publishDate |
2016-03-01 |
description |
The present paper deals with experimental testing of the readability of RFID transponders in the sputtered magnesite dust layer under different conditions. In the first part of the article describes the measurement and the used.equipment. The second part includes the creation of experimental model with a subsequent evaluation of measurements for the purposes of carrying out verification of the applicability of the selected RFID transponders in the circumstances. In conclusion, the publication is evaluated the progress of the experiment and the results of measurements determining the environmental conditions and meets the requirements of the application. |
topic |
rfid transponder magnesite dust measuremnt |
url |
http://www.actatecnologia.eu/issues/2016/I_2016_02_Balog_Mindas_Szilagyi_Duplakova_Knapcikova.pdf |
work_keys_str_mv |
AT michalbalog technicalmeasurementandanalysisoftheimpactofmagnesitedepositofdustonthereadabilityofrfidtransponders AT miroslavmindas technicalmeasurementandanalysisoftheimpactofmagnesitedepositofdustonthereadabilityofrfidtransponders AT erikszilagyi technicalmeasurementandanalysisoftheimpactofmagnesitedepositofdustonthereadabilityofrfidtransponders AT darinaduplakova technicalmeasurementandanalysisoftheimpactofmagnesitedepositofdustonthereadabilityofrfidtransponders AT luciaknapcikova technicalmeasurementandanalysisoftheimpactofmagnesitedepositofdustonthereadabilityofrfidtransponders |
_version_ |
1725133482842128384 |