Introduction of a C6D6 detector system on the Back-n of CSNS

Radiative neutron capture cross sections are very important in the field of basic physics research and nuclear device R&D. The Back-n white neutron beam line of China Spallation Neutron Source (CSNS) is the first spallation neutron beam line in China. On the purpose for radiative neutron capture...

Full description

Bibliographic Details
Main Authors: Ren Jie, Ruan Xichao, Bao Jie, Luan Guangyuan, Huang Hanxiong, Nie Yangbo
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:EPJ Web of Conferences
Subjects:
Online Access:https://www.epj-conferences.org/articles/epjconf/pdf/2020/15/epjconf_nd2019_17021.pdf
id doaj-84884ef301e945e6b7afdf63b2635fee
record_format Article
spelling doaj-84884ef301e945e6b7afdf63b2635fee2021-08-02T19:19:21ZengEDP SciencesEPJ Web of Conferences2100-014X2020-01-012391702110.1051/epjconf/202023917021epjconf_nd2019_17021Introduction of a C6D6 detector system on the Back-n of CSNSRen Jie0Ruan Xichao1Bao Jie2Luan Guangyuan3Huang Hanxiong4Nie Yangbo5Key Laboratory of Nuclear Data, China Institute of Atomic EnergyKey Laboratory of Nuclear Data, China Institute of Atomic EnergyKey Laboratory of Nuclear Data, China Institute of Atomic EnergyKey Laboratory of Nuclear Data, China Institute of Atomic EnergyKey Laboratory of Nuclear Data, China Institute of Atomic EnergyKey Laboratory of Nuclear Data, China Institute of Atomic EnergyRadiative neutron capture cross sections are very important in the field of basic physics research and nuclear device R&D. The Back-n white neutron beam line of China Spallation Neutron Source (CSNS) is the first spallation neutron beam line in China. On the purpose for radiative neutron capture cross section measurement, a C6D6 detector system was built in the Back-n experimental station. The pulse height weighting technique (PHWT) was used to make the system’s detective efficiency independent of the cascade path and the energy of cascade gamma rays. The neutron energy spectrum was measured for the energy between 1eV and 80keV with a 6Li loaded ZnS scintillation detector. Besides, a testing experiment with 197Au and 169Tm samples was carried out to examine this system. According to the preliminary results, this C6D6 detector system can be used to perform neutron capture cross section measurement.https://www.epj-conferences.org/articles/epjconf/pdf/2020/15/epjconf_nd2019_17021.pdfc6d6 detectorphwtneutron capture cross sectionwhite neutron source
collection DOAJ
language English
format Article
sources DOAJ
author Ren Jie
Ruan Xichao
Bao Jie
Luan Guangyuan
Huang Hanxiong
Nie Yangbo
spellingShingle Ren Jie
Ruan Xichao
Bao Jie
Luan Guangyuan
Huang Hanxiong
Nie Yangbo
Introduction of a C6D6 detector system on the Back-n of CSNS
EPJ Web of Conferences
c6d6 detector
phwt
neutron capture cross section
white neutron source
author_facet Ren Jie
Ruan Xichao
Bao Jie
Luan Guangyuan
Huang Hanxiong
Nie Yangbo
author_sort Ren Jie
title Introduction of a C6D6 detector system on the Back-n of CSNS
title_short Introduction of a C6D6 detector system on the Back-n of CSNS
title_full Introduction of a C6D6 detector system on the Back-n of CSNS
title_fullStr Introduction of a C6D6 detector system on the Back-n of CSNS
title_full_unstemmed Introduction of a C6D6 detector system on the Back-n of CSNS
title_sort introduction of a c6d6 detector system on the back-n of csns
publisher EDP Sciences
series EPJ Web of Conferences
issn 2100-014X
publishDate 2020-01-01
description Radiative neutron capture cross sections are very important in the field of basic physics research and nuclear device R&D. The Back-n white neutron beam line of China Spallation Neutron Source (CSNS) is the first spallation neutron beam line in China. On the purpose for radiative neutron capture cross section measurement, a C6D6 detector system was built in the Back-n experimental station. The pulse height weighting technique (PHWT) was used to make the system’s detective efficiency independent of the cascade path and the energy of cascade gamma rays. The neutron energy spectrum was measured for the energy between 1eV and 80keV with a 6Li loaded ZnS scintillation detector. Besides, a testing experiment with 197Au and 169Tm samples was carried out to examine this system. According to the preliminary results, this C6D6 detector system can be used to perform neutron capture cross section measurement.
topic c6d6 detector
phwt
neutron capture cross section
white neutron source
url https://www.epj-conferences.org/articles/epjconf/pdf/2020/15/epjconf_nd2019_17021.pdf
work_keys_str_mv AT renjie introductionofac6d6detectorsystemonthebacknofcsns
AT ruanxichao introductionofac6d6detectorsystemonthebacknofcsns
AT baojie introductionofac6d6detectorsystemonthebacknofcsns
AT luanguangyuan introductionofac6d6detectorsystemonthebacknofcsns
AT huanghanxiong introductionofac6d6detectorsystemonthebacknofcsns
AT nieyangbo introductionofac6d6detectorsystemonthebacknofcsns
_version_ 1721227622551126016