Detection of Zinc in Nail Samples of Iron Welders

The current study was conducted to quantify zinc in nail samples of iron welders from different areas of Lahore, Pakistan. This study intended to assess nutritional deficiencies of zinc in welders. As nails serve a beneficial biomarker of concentrations of trace elements, hence in the present study...

Full description

Bibliographic Details
Main Authors: Hina Chaudhry, Maryam Ijaz, Gul e Fatima, Aisha Masood, Numrah Nisar
Format: Article
Language:English
Published: National Centre of Excellence in Analytical Chemsitry 2017-06-01
Series:Pakistan Journal of Analytical & Environmental Chemistry
Subjects:
Online Access:http://www.ceacsu.edu.pk/PDF%20file/Volume%2018%20Issue%201/64-68-Galley%20Proof%20PJAEC-18032016-36.pdf
id doaj-84bcc4af6b5744c5addad2098d154e8f
record_format Article
spelling doaj-84bcc4af6b5744c5addad2098d154e8f2020-11-25T02:46:25ZengNational Centre of Excellence in Analytical ChemsitryPakistan Journal of Analytical & Environmental Chemistry1996-918X2221-52552017-06-01181646810.21743/pjaec/2017.06.06Detection of Zinc in Nail Samples of Iron WeldersHina Chaudhry0Maryam Ijaz1Gul e Fatima2Aisha Masood3Numrah Nisar4Department of Environmental Science, Lahore College for Women University, Lahore, PakistanDepartment of Environmental Science, Lahore College for Women University, Lahore, PakistanDepartment of Environmental Science, Lahore College for Women University, Lahore, PakistanDepartment of Environmental Science, Lahore College for Women University, Lahore, PakistanDepartment of Environmental Science, Lahore College for Women University, Lahore, PakistanThe current study was conducted to quantify zinc in nail samples of iron welders from different areas of Lahore, Pakistan. This study intended to assess nutritional deficiencies of zinc in welders. As nails serve a beneficial biomarker of concentrations of trace elements, hence in the present study the nails of welders were used for monitoring. The total number of nail samples collected from workers of iron welding shops, were 40. In a standardized washing procedure the nail samples were scrapped and cleaned of dust particles with nonionic detergent (Triton X-100) and then nail samples were digested afterwards in acid mixture. The concentration of zinc was evaluated by atomic absorption spectrophotometer. The results revealed that concentration of zinc in nail samples ranged 0.297 – 1.718 mg/kg and averaged at 0.88±0.39 mg/kg which is below the ideal zinc levels in nail samples. Correlation of zinc (mg/kg) was significant with age (0.214< 0.5), weight (0.320< 0.5) and Body Mass Index (0.268< 0.5) of the welders, while a weak correlation of zinc (mg/kg) was found with height (0.042< 0.5) of the welders.http://www.ceacsu.edu.pk/PDF%20file/Volume%2018%20Issue%201/64-68-Galley%20Proof%20PJAEC-18032016-36.pdfZincNail samplesIron weldersAtomic absorption spectrophotometer
collection DOAJ
language English
format Article
sources DOAJ
author Hina Chaudhry
Maryam Ijaz
Gul e Fatima
Aisha Masood
Numrah Nisar
spellingShingle Hina Chaudhry
Maryam Ijaz
Gul e Fatima
Aisha Masood
Numrah Nisar
Detection of Zinc in Nail Samples of Iron Welders
Pakistan Journal of Analytical & Environmental Chemistry
Zinc
Nail samples
Iron welders
Atomic absorption spectrophotometer
author_facet Hina Chaudhry
Maryam Ijaz
Gul e Fatima
Aisha Masood
Numrah Nisar
author_sort Hina Chaudhry
title Detection of Zinc in Nail Samples of Iron Welders
title_short Detection of Zinc in Nail Samples of Iron Welders
title_full Detection of Zinc in Nail Samples of Iron Welders
title_fullStr Detection of Zinc in Nail Samples of Iron Welders
title_full_unstemmed Detection of Zinc in Nail Samples of Iron Welders
title_sort detection of zinc in nail samples of iron welders
publisher National Centre of Excellence in Analytical Chemsitry
series Pakistan Journal of Analytical & Environmental Chemistry
issn 1996-918X
2221-5255
publishDate 2017-06-01
description The current study was conducted to quantify zinc in nail samples of iron welders from different areas of Lahore, Pakistan. This study intended to assess nutritional deficiencies of zinc in welders. As nails serve a beneficial biomarker of concentrations of trace elements, hence in the present study the nails of welders were used for monitoring. The total number of nail samples collected from workers of iron welding shops, were 40. In a standardized washing procedure the nail samples were scrapped and cleaned of dust particles with nonionic detergent (Triton X-100) and then nail samples were digested afterwards in acid mixture. The concentration of zinc was evaluated by atomic absorption spectrophotometer. The results revealed that concentration of zinc in nail samples ranged 0.297 – 1.718 mg/kg and averaged at 0.88±0.39 mg/kg which is below the ideal zinc levels in nail samples. Correlation of zinc (mg/kg) was significant with age (0.214< 0.5), weight (0.320< 0.5) and Body Mass Index (0.268< 0.5) of the welders, while a weak correlation of zinc (mg/kg) was found with height (0.042< 0.5) of the welders.
topic Zinc
Nail samples
Iron welders
Atomic absorption spectrophotometer
url http://www.ceacsu.edu.pk/PDF%20file/Volume%2018%20Issue%201/64-68-Galley%20Proof%20PJAEC-18032016-36.pdf
work_keys_str_mv AT hinachaudhry detectionofzincinnailsamplesofironwelders
AT maryamijaz detectionofzincinnailsamplesofironwelders
AT gulefatima detectionofzincinnailsamplesofironwelders
AT aishamasood detectionofzincinnailsamplesofironwelders
AT numrahnisar detectionofzincinnailsamplesofironwelders
_version_ 1724758412507480064