An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study

Aim: The aim of this study is to compare and to evaluate sealing ability of newly introduced C-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique using a dye extraction method. Materials and Methodology: Sixty extracted maxillary central incisors were de...

Full description

Bibliographic Details
Main Authors: Tapati Manohar Sinhal, Ruchi Rani Purvesh Shah, Pratik Subhas Jais, Nimisha Chinmay Shah, Krupali Dhirubhai Hadwani, Tushar Rothe, Neha Nilesh Sinhal
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:Contemporary Clinical Dentistry
Subjects:
Online Access:http://www.contempclindent.org/article.asp?issn=0976-237X;year=2018;volume=9;issue=2;spage=164;epage=169;aulast=Sinhal
id doaj-865cef9802fc4239ad79bd73799799a5
record_format Article
spelling doaj-865cef9802fc4239ad79bd73799799a52020-11-24T22:48:55ZengWolters Kluwer Medknow PublicationsContemporary Clinical Dentistry0976-237X0976-23612018-01-019216416910.4103/ccd.ccd_722_17An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction studyTapati Manohar SinhalRuchi Rani Purvesh ShahPratik Subhas JaisNimisha Chinmay ShahKrupali Dhirubhai HadwaniTushar RotheNeha Nilesh SinhalAim: The aim of this study is to compare and to evaluate sealing ability of newly introduced C-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique using a dye extraction method. Materials and Methodology: Sixty extracted maxillary central incisors were decoronated below the cementoenamel junction. Working length was established, and biomechanical preparation was done using K3 rotary files with standard irrigation protocol. Teeth were divided into three groups according to the obturation protocol; Group I-Cold lateral condensation, Group II-Thermoplasticized gutta-percha, and Group III-C-Point obturating system. After obturation all samples were subjected to microleakage assessment using dye extraction method. Obtained scores will be statistical analyzed using ANOVA test and post hoc Tukey's test. Results: One-way analysis of variance revealed that there is significant difference among the three groups with P value (0.000 < 0.05). Tukey's HSD post hoc tests for multiple comparisons test shows that the Group II and III perform significantly better than Group I. Group III performs better than Group II with no significant difference. Conclusion: All the obturating technique showed some degree of microleakage. Root canals filled with C-point system showed least microleakage followed by thermoplasticized obturating technique with no significant difference among them. C-point obturation system could be an alternative to the cold lateral condensation technique.http://www.contempclindent.org/article.asp?issn=0976-237X;year=2018;volume=9;issue=2;spage=164;epage=169;aulast=SinhalApical microleakagecold lateral condensationC-point obturation systemdye extractionthermoplasticized obturating technique
collection DOAJ
language English
format Article
sources DOAJ
author Tapati Manohar Sinhal
Ruchi Rani Purvesh Shah
Pratik Subhas Jais
Nimisha Chinmay Shah
Krupali Dhirubhai Hadwani
Tushar Rothe
Neha Nilesh Sinhal
spellingShingle Tapati Manohar Sinhal
Ruchi Rani Purvesh Shah
Pratik Subhas Jais
Nimisha Chinmay Shah
Krupali Dhirubhai Hadwani
Tushar Rothe
Neha Nilesh Sinhal
An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study
Contemporary Clinical Dentistry
Apical microleakage
cold lateral condensation
C-point obturation system
dye extraction
thermoplasticized obturating technique
author_facet Tapati Manohar Sinhal
Ruchi Rani Purvesh Shah
Pratik Subhas Jais
Nimisha Chinmay Shah
Krupali Dhirubhai Hadwani
Tushar Rothe
Neha Nilesh Sinhal
author_sort Tapati Manohar Sinhal
title An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study
title_short An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study
title_full An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study
title_fullStr An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study
title_full_unstemmed An In vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: A dye extraction study
title_sort in vitro comparison and evaluation of sealing ability of newly introduced c-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique: a dye extraction study
publisher Wolters Kluwer Medknow Publications
series Contemporary Clinical Dentistry
issn 0976-237X
0976-2361
publishDate 2018-01-01
description Aim: The aim of this study is to compare and to evaluate sealing ability of newly introduced C-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique using a dye extraction method. Materials and Methodology: Sixty extracted maxillary central incisors were decoronated below the cementoenamel junction. Working length was established, and biomechanical preparation was done using K3 rotary files with standard irrigation protocol. Teeth were divided into three groups according to the obturation protocol; Group I-Cold lateral condensation, Group II-Thermoplasticized gutta-percha, and Group III-C-Point obturating system. After obturation all samples were subjected to microleakage assessment using dye extraction method. Obtained scores will be statistical analyzed using ANOVA test and post hoc Tukey's test. Results: One-way analysis of variance revealed that there is significant difference among the three groups with P value (0.000 < 0.05). Tukey's HSD post hoc tests for multiple comparisons test shows that the Group II and III perform significantly better than Group I. Group III performs better than Group II with no significant difference. Conclusion: All the obturating technique showed some degree of microleakage. Root canals filled with C-point system showed least microleakage followed by thermoplasticized obturating technique with no significant difference among them. C-point obturation system could be an alternative to the cold lateral condensation technique.
topic Apical microleakage
cold lateral condensation
C-point obturation system
dye extraction
thermoplasticized obturating technique
url http://www.contempclindent.org/article.asp?issn=0976-237X;year=2018;volume=9;issue=2;spage=164;epage=169;aulast=Sinhal
work_keys_str_mv AT tapatimanoharsinhal aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT ruchiranipurveshshah aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT pratiksubhasjais aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT nimishachinmayshah aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT krupalidhirubhaihadwani aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT tusharrothe aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT nehanileshsinhal aninvitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT tapatimanoharsinhal invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT ruchiranipurveshshah invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT pratiksubhasjais invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT nimishachinmayshah invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT krupalidhirubhaihadwani invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT tusharrothe invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
AT nehanileshsinhal invitrocomparisonandevaluationofsealingabilityofnewlyintroducedcpointsystemcoldlateralcondensationandthermoplasticizedguttaperchaobturatingtechniqueadyeextractionstudy
_version_ 1725678073126322176