Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study
Abstract Background To determine normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the Achilles tendon. Methods Using the VTIQ mode with the Acuson S3000™ (Siemens Healthcare, Erlangen, Germany), we measured the shear wave velocity (SWV) in m/s and the diameter in...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2018-05-01
|
Series: | BMC Musculoskeletal Disorders |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1186/s12891-018-2056-0 |
id |
doaj-8830e57700b04a6091edcb992b602410 |
---|---|
record_format |
Article |
spelling |
doaj-8830e57700b04a6091edcb992b6024102020-11-24T21:52:56ZengBMCBMC Musculoskeletal Disorders1471-24742018-05-011911710.1186/s12891-018-2056-0Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section studyJonas Wakker0Wolfgang Kratzer1Tilmann Graeter2Julian Schmidberger3PhD for the Elasto Study GroupDepartment of General, Thoracic and Vascular Surgery, Triemli City HospitalDepartment of Internal Medicine I, University Hospital UlmDepartment of Interventional and Diagnostic Radiology, University Hospital UlmDepartment of Internal Medicine I, University Hospital UlmAbstract Background To determine normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the Achilles tendon. Methods Using the VTIQ mode with the Acuson S3000™ (Siemens Healthcare, Erlangen, Germany), we measured the shear wave velocity (SWV) in m/s and the diameter in mm of both Achilles tendons in 182 healthy volunteers. The tendon was displayed in a sagittal view with a relaxed tendon. The parameters were tested for correlations with the anthropometric data of the subjects, between the genders and different age groups, as well as information obtained from the history, such as smoking and sporting activities. Results Using a sagittal acoustic window, we determined a mean SWV of 9.09 ± 0.71 m/s for the left Achilles tendon and 9.17 ± 0.61 m/s for the right. There was a significant difference between the results for the right and left side (p < 0.05). The diameter on the left was 4.7 ± 0.9 mm. On the right, it was 4.8 ± 0.9 mm. Likewise there was a significant difference between the results for the diameter of the left and right side (p < 0.05). Neither gender, body mass index (BMI) nor age had a significant effect on either of the measured parameters (p > 0.05). The same goes for the consumption of tobacco and alcohol (p > 0.05). Conclusions Age, gender, BMI, smoking or the consumption of alcohol did not affect either the elasticity or the diameter of the Achilles tendon.http://link.springer.com/article/10.1186/s12891-018-2056-0ARFIElastographyAchilles tendonShear wave elastographyVTIQ |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jonas Wakker Wolfgang Kratzer Tilmann Graeter Julian Schmidberger PhD for the Elasto Study Group |
spellingShingle |
Jonas Wakker Wolfgang Kratzer Tilmann Graeter Julian Schmidberger PhD for the Elasto Study Group Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study BMC Musculoskeletal Disorders ARFI Elastography Achilles tendon Shear wave elastography VTIQ |
author_facet |
Jonas Wakker Wolfgang Kratzer Tilmann Graeter Julian Schmidberger PhD for the Elasto Study Group |
author_sort |
Jonas Wakker |
title |
Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study |
title_short |
Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study |
title_full |
Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study |
title_fullStr |
Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study |
title_full_unstemmed |
Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study |
title_sort |
elasticity standard values of the achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study |
publisher |
BMC |
series |
BMC Musculoskeletal Disorders |
issn |
1471-2474 |
publishDate |
2018-05-01 |
description |
Abstract Background To determine normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the Achilles tendon. Methods Using the VTIQ mode with the Acuson S3000™ (Siemens Healthcare, Erlangen, Germany), we measured the shear wave velocity (SWV) in m/s and the diameter in mm of both Achilles tendons in 182 healthy volunteers. The tendon was displayed in a sagittal view with a relaxed tendon. The parameters were tested for correlations with the anthropometric data of the subjects, between the genders and different age groups, as well as information obtained from the history, such as smoking and sporting activities. Results Using a sagittal acoustic window, we determined a mean SWV of 9.09 ± 0.71 m/s for the left Achilles tendon and 9.17 ± 0.61 m/s for the right. There was a significant difference between the results for the right and left side (p < 0.05). The diameter on the left was 4.7 ± 0.9 mm. On the right, it was 4.8 ± 0.9 mm. Likewise there was a significant difference between the results for the diameter of the left and right side (p < 0.05). Neither gender, body mass index (BMI) nor age had a significant effect on either of the measured parameters (p > 0.05). The same goes for the consumption of tobacco and alcohol (p > 0.05). Conclusions Age, gender, BMI, smoking or the consumption of alcohol did not affect either the elasticity or the diameter of the Achilles tendon. |
topic |
ARFI Elastography Achilles tendon Shear wave elastography VTIQ |
url |
http://link.springer.com/article/10.1186/s12891-018-2056-0 |
work_keys_str_mv |
AT jonaswakker elasticitystandardvaluesoftheachillestendonassessedwithacousticradiationforceimpulseelastographyonhealthyvolunteersacrosssectionstudy AT wolfgangkratzer elasticitystandardvaluesoftheachillestendonassessedwithacousticradiationforceimpulseelastographyonhealthyvolunteersacrosssectionstudy AT tilmanngraeter elasticitystandardvaluesoftheachillestendonassessedwithacousticradiationforceimpulseelastographyonhealthyvolunteersacrosssectionstudy AT julianschmidberger elasticitystandardvaluesoftheachillestendonassessedwithacousticradiationforceimpulseelastographyonhealthyvolunteersacrosssectionstudy AT phdfortheelastostudygroup elasticitystandardvaluesoftheachillestendonassessedwithacousticradiationforceimpulseelastographyonhealthyvolunteersacrosssectionstudy |
_version_ |
1725873980953329664 |