IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES

Ground wires are bare conductors which serve to protect the power line from the lightning strike. This article deals with the calculation of the series impedance of the 110 kV overhead power line with one ground wire. The article examines the effect of the ground wire on the series impedance of th...

Full description

Bibliographic Details
Main Authors: Anastázia MARGITOVÁ, Martin KANÁLIK, Michal KOLCUN
Format: Article
Language:English
Published: Technical University of Kosice 2019-03-01
Series:Acta Electrotechnica et Informatica
Subjects:
Online Access:http://www.aei.tuke.sk/papers/2019/1/02_MARGITOVA
id doaj-884e0d6344e542098f7cb904879002af
record_format Article
spelling doaj-884e0d6344e542098f7cb904879002af2020-11-24T22:19:07ZengTechnical University of Kosice Acta Electrotechnica et Informatica1335-82431338-39572019-03-01191111810.15546/aeei-2019-0002IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINESAnastázia MARGITOVÁ0Martin KANÁLIK1Michal KOLCUN2Department of Electric Power Engineering Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, Slovak RepublicDepartment of Electric Power Engineering Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, Slovak RepublicDepartment of Electric Power Engineering Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, Slovak RepublicGround wires are bare conductors which serve to protect the power line from the lightning strike. This article deals with the calculation of the series impedance of the 110 kV overhead power line with one ground wire. The article examines the effect of the ground wire on the series impedance of the 110 kV power line compared to the same power line without the ground wire. In the next part, the principle of elimination of the ground wire is described and the method of including the influence of the ground wire on the series impedance of phase conductors of the 110 kV power line is also described. The conclusion deals with the calculation of voltage and current conditions of the 110 kV power line modelled without the ground wire, with the ground wire and with elimination (reduction) of the ground wire (the ground wire is not modelled, but its effect is included in the series impedance of phase conductors) and then comparison of given models.http://www.aei.tuke.sk/papers/2019/1/02_MARGITOVAseries impedance of overhead power lines
collection DOAJ
language English
format Article
sources DOAJ
author Anastázia MARGITOVÁ
Martin KANÁLIK
Michal KOLCUN
spellingShingle Anastázia MARGITOVÁ
Martin KANÁLIK
Michal KOLCUN
IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
Acta Electrotechnica et Informatica
series impedance of overhead power lines
author_facet Anastázia MARGITOVÁ
Martin KANÁLIK
Michal KOLCUN
author_sort Anastázia MARGITOVÁ
title IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
title_short IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
title_full IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
title_fullStr IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
title_full_unstemmed IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
title_sort impact of ground wires on the series impedance, voltage and current conditions of overhead power lines
publisher Technical University of Kosice
series Acta Electrotechnica et Informatica
issn 1335-8243
1338-3957
publishDate 2019-03-01
description Ground wires are bare conductors which serve to protect the power line from the lightning strike. This article deals with the calculation of the series impedance of the 110 kV overhead power line with one ground wire. The article examines the effect of the ground wire on the series impedance of the 110 kV power line compared to the same power line without the ground wire. In the next part, the principle of elimination of the ground wire is described and the method of including the influence of the ground wire on the series impedance of phase conductors of the 110 kV power line is also described. The conclusion deals with the calculation of voltage and current conditions of the 110 kV power line modelled without the ground wire, with the ground wire and with elimination (reduction) of the ground wire (the ground wire is not modelled, but its effect is included in the series impedance of phase conductors) and then comparison of given models.
topic series impedance of overhead power lines
url http://www.aei.tuke.sk/papers/2019/1/02_MARGITOVA
work_keys_str_mv AT anastaziamargitova impactofgroundwiresontheseriesimpedancevoltageandcurrentconditionsofoverheadpowerlines
AT martinkanalik impactofgroundwiresontheseriesimpedancevoltageandcurrentconditionsofoverheadpowerlines
AT michalkolcun impactofgroundwiresontheseriesimpedancevoltageandcurrentconditionsofoverheadpowerlines
_version_ 1725779982516486144