IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES
Ground wires are bare conductors which serve to protect the power line from the lightning strike. This article deals with the calculation of the series impedance of the 110 kV overhead power line with one ground wire. The article examines the effect of the ground wire on the series impedance of th...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Technical University of Kosice
2019-03-01
|
Series: | Acta Electrotechnica et Informatica |
Subjects: | |
Online Access: | http://www.aei.tuke.sk/papers/2019/1/02_MARGITOVA |
id |
doaj-884e0d6344e542098f7cb904879002af |
---|---|
record_format |
Article |
spelling |
doaj-884e0d6344e542098f7cb904879002af2020-11-24T22:19:07ZengTechnical University of Kosice Acta Electrotechnica et Informatica1335-82431338-39572019-03-01191111810.15546/aeei-2019-0002IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINESAnastázia MARGITOVÁ0Martin KANÁLIK1Michal KOLCUN2Department of Electric Power Engineering Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, Slovak RepublicDepartment of Electric Power Engineering Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, Slovak RepublicDepartment of Electric Power Engineering Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, Slovak RepublicGround wires are bare conductors which serve to protect the power line from the lightning strike. This article deals with the calculation of the series impedance of the 110 kV overhead power line with one ground wire. The article examines the effect of the ground wire on the series impedance of the 110 kV power line compared to the same power line without the ground wire. In the next part, the principle of elimination of the ground wire is described and the method of including the influence of the ground wire on the series impedance of phase conductors of the 110 kV power line is also described. The conclusion deals with the calculation of voltage and current conditions of the 110 kV power line modelled without the ground wire, with the ground wire and with elimination (reduction) of the ground wire (the ground wire is not modelled, but its effect is included in the series impedance of phase conductors) and then comparison of given models.http://www.aei.tuke.sk/papers/2019/1/02_MARGITOVAseries impedance of overhead power lines |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Anastázia MARGITOVÁ Martin KANÁLIK Michal KOLCUN |
spellingShingle |
Anastázia MARGITOVÁ Martin KANÁLIK Michal KOLCUN IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES Acta Electrotechnica et Informatica series impedance of overhead power lines |
author_facet |
Anastázia MARGITOVÁ Martin KANÁLIK Michal KOLCUN |
author_sort |
Anastázia MARGITOVÁ |
title |
IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES |
title_short |
IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES |
title_full |
IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES |
title_fullStr |
IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES |
title_full_unstemmed |
IMPACT OF GROUND WIRES ON THE SERIES IMPEDANCE, VOLTAGE AND CURRENT CONDITIONS OF OVERHEAD POWER LINES |
title_sort |
impact of ground wires on the series impedance, voltage and current conditions of overhead power lines |
publisher |
Technical University of Kosice |
series |
Acta Electrotechnica et Informatica |
issn |
1335-8243 1338-3957 |
publishDate |
2019-03-01 |
description |
Ground wires are bare conductors which serve to protect the power line from the lightning strike. This article deals with the
calculation of the series impedance of the 110 kV overhead power line with one ground wire. The article examines the effect of the
ground wire on the series impedance of the 110 kV power line compared to the same power line without the ground wire. In the next
part, the principle of elimination of the ground wire is described and the method of including the influence of the ground wire on the
series impedance of phase conductors of the 110 kV power line is also described. The conclusion deals with the calculation of voltage
and current conditions of the 110 kV power line modelled without the ground wire, with the ground wire and with elimination
(reduction) of the ground wire (the ground wire is not modelled, but its effect is included in the series impedance of phase conductors)
and then comparison of given models. |
topic |
series impedance of overhead power lines |
url |
http://www.aei.tuke.sk/papers/2019/1/02_MARGITOVA |
work_keys_str_mv |
AT anastaziamargitova impactofgroundwiresontheseriesimpedancevoltageandcurrentconditionsofoverheadpowerlines AT martinkanalik impactofgroundwiresontheseriesimpedancevoltageandcurrentconditionsofoverheadpowerlines AT michalkolcun impactofgroundwiresontheseriesimpedancevoltageandcurrentconditionsofoverheadpowerlines |