Case Study Of Baji Gas Station Unit One And Three For Performance Determination

Baiji thermal station supplied by heavy fuel HFO from Baiji refinery, while the gas station is operated by heavy fuel HFO and light fuel LFO, the first unit operates using LFO, the third unit operates using HFO. The results showed that the specific fuel consumption is reduced by rising the load, whe...

Full description

Bibliographic Details
Main Author: Ahmed H. Ahmed
Format: Article
Language:English
Published: Tikrit University 2013-05-01
Series:Tikrit Journal of Engineering Sciences
Subjects:
Online Access:http://www.tj-es.com/ojs/index.php/tjes/article/view/204
id doaj-885ac66efa6e4be9a17ac0bd30fad169
record_format Article
spelling doaj-885ac66efa6e4be9a17ac0bd30fad1692020-11-25T00:21:32ZengTikrit UniversityTikrit Journal of Engineering Sciences1813-162X2312-75892013-05-011744555144Case Study Of Baji Gas Station Unit One And Three For Performance DeterminationAhmed H. AhmedBaiji thermal station supplied by heavy fuel HFO from Baiji refinery, while the gas station is operated by heavy fuel HFO and light fuel LFO, the first unit operates using LFO, the third unit operates using HFO. The results showed that the specific fuel consumption is reduced by rising the load, when the load is reduced to 20Mw s.f.c almost 0.765m<sup>3</sup>/Mw.hr this rate start to fall to become 0.35m<sup>3</sup>/Mw.hr when the unit operate near its maximum capacity for LFO, while the heavy fuel increases by 15% for the same number above. It's correct that LFO is good but it is expensive which costs 1000$ per imported ton , in order to cover the load of 8000Mw for one year itcosts 1.92E+10$ for imported LFO ,9.6E+10$ for the local LFO, and 2.8E+9$ for HFO, the difference is obvious which is ten times the total cost. Also the studied performance of the gas units showed that the net is experience from a  downturn of frequency along 24hr except in the let hours at night, while the allowed frequency is 50HZ±1.5, and the true efficiency of the units is a function of the load which stabilized at 29%±0.2 for the first unit and 25% for the third unit, while the thermal efficiency is stabilized at48% for the first unit and 51% for the third, therefore the unit efficiency is improved by 4% when we use LFO. When in take in to account the pollution, the heavy fuel HFO contains 4.5% sulpher which releases sulpheric acid and 1% vanadium treated by adding inhibitor about 1.5L/Mw.hr, these ratio are not considered for LFO with respect to HFOhttp://www.tj-es.com/ojs/index.php/tjes/article/view/204Power Station, Gas Station, Economic Energy, Fuel, Efficiency.
collection DOAJ
language English
format Article
sources DOAJ
author Ahmed H. Ahmed
spellingShingle Ahmed H. Ahmed
Case Study Of Baji Gas Station Unit One And Three For Performance Determination
Tikrit Journal of Engineering Sciences
Power Station, Gas Station, Economic Energy, Fuel, Efficiency.
author_facet Ahmed H. Ahmed
author_sort Ahmed H. Ahmed
title Case Study Of Baji Gas Station Unit One And Three For Performance Determination
title_short Case Study Of Baji Gas Station Unit One And Three For Performance Determination
title_full Case Study Of Baji Gas Station Unit One And Three For Performance Determination
title_fullStr Case Study Of Baji Gas Station Unit One And Three For Performance Determination
title_full_unstemmed Case Study Of Baji Gas Station Unit One And Three For Performance Determination
title_sort case study of baji gas station unit one and three for performance determination
publisher Tikrit University
series Tikrit Journal of Engineering Sciences
issn 1813-162X
2312-7589
publishDate 2013-05-01
description Baiji thermal station supplied by heavy fuel HFO from Baiji refinery, while the gas station is operated by heavy fuel HFO and light fuel LFO, the first unit operates using LFO, the third unit operates using HFO. The results showed that the specific fuel consumption is reduced by rising the load, when the load is reduced to 20Mw s.f.c almost 0.765m<sup>3</sup>/Mw.hr this rate start to fall to become 0.35m<sup>3</sup>/Mw.hr when the unit operate near its maximum capacity for LFO, while the heavy fuel increases by 15% for the same number above. It's correct that LFO is good but it is expensive which costs 1000$ per imported ton , in order to cover the load of 8000Mw for one year itcosts 1.92E+10$ for imported LFO ,9.6E+10$ for the local LFO, and 2.8E+9$ for HFO, the difference is obvious which is ten times the total cost. Also the studied performance of the gas units showed that the net is experience from a  downturn of frequency along 24hr except in the let hours at night, while the allowed frequency is 50HZ±1.5, and the true efficiency of the units is a function of the load which stabilized at 29%±0.2 for the first unit and 25% for the third unit, while the thermal efficiency is stabilized at48% for the first unit and 51% for the third, therefore the unit efficiency is improved by 4% when we use LFO. When in take in to account the pollution, the heavy fuel HFO contains 4.5% sulpher which releases sulpheric acid and 1% vanadium treated by adding inhibitor about 1.5L/Mw.hr, these ratio are not considered for LFO with respect to HFO
topic Power Station, Gas Station, Economic Energy, Fuel, Efficiency.
url http://www.tj-es.com/ojs/index.php/tjes/article/view/204
work_keys_str_mv AT ahmedhahmed casestudyofbajigasstationunitoneandthreeforperformancedetermination
_version_ 1725362253156319232