The influence of a swab type on the results of point-of-care tests

Abstract Most point-of-care tests (POCT) use swabs for sampling and/or for applying a sample on the test. A variety of swabs differing in tip materials is commercially available. Different tip materials have different chemical and physical characteristics which might influence the specimen collectio...

Full description

Bibliographic Details
Main Authors: Aleksandra Anna Zasada, Katarzyna Zacharczuk, Katarzyna Woźnica, Małgorzata Główka, Robert Ziółkowski, Elżbieta Malinowska
Format: Article
Language:English
Published: SpringerOpen 2020-03-01
Series:AMB Express
Subjects:
Online Access:http://link.springer.com/article/10.1186/s13568-020-00978-9
id doaj-89b6648bfa4e477f8d47314a25ac3ff9
record_format Article
spelling doaj-89b6648bfa4e477f8d47314a25ac3ff92020-11-25T02:09:19ZengSpringerOpenAMB Express2191-08552020-03-011011610.1186/s13568-020-00978-9The influence of a swab type on the results of point-of-care testsAleksandra Anna Zasada0Katarzyna Zacharczuk1Katarzyna Woźnica2Małgorzata Główka3Robert Ziółkowski4Elżbieta Malinowska5Department of Sera and Vaccines Evaluation, National Institute of Public Health-National Institute of HygieneDepartment of Bacteriology and Biocontamination Control, National Institute of Public Health-National Institute of HygieneDepartment of Sera and Vaccines Evaluation, National Institute of Public Health-National Institute of HygieneDepartment of Sera and Vaccines Evaluation, National Institute of Public Health-National Institute of HygieneFaculty of Chemistry, The Chair of Medical Biotechnology, Warsaw University of TechnologyFaculty of Chemistry, The Chair of Medical Biotechnology, Warsaw University of TechnologyAbstract Most point-of-care tests (POCT) use swabs for sampling and/or for applying a sample on the test. A variety of swabs differing in tip materials is commercially available. Different tip materials have different chemical and physical characteristics which might influence the specimen collection and release. We investigated properties of various types of swabs used in clinical diagnostics with focusing on two kinds of analytes, DNA and proteins, which are most often used targets in POCT. As the model samples we used diphtheria toxoid NIBSC 69/017 for investigating recovery of protein analytes such as antigens and bacterial strains of Escherichia coli ATCC 25922, diphtheria toxin-producing Corynebacterium diphtheriae NCTC 10648, and the clinical isolate nontoxigenic C. diphtheriae 5820/15 for investigating the recovery of nucleic acids. We investigated four types of swabs most commonly used in clinical diagnostics in terms of absorption capacity and efficiency of release of nucleic acids and proteins. Volume uptake was measured in milligrams. For DNA release various washing out buffers were used and the amount of released DNA was measured spectrophotometrically. The amount of protein released from the swabs were examined using the Lowry assay. We observed statistically significant differences (p < 0.05) in the mean weights of absorbed liquid, in the DNA recovery and protein recovery by the four variety of swab examined. However, the efficiency of DNA and protein release was not correlated to the absorbed volume of a sample, but rather to the properties of swabs. The swab composition and structure can have a significant impact on the collection and release efficiency of a sample. Therefore, validation of POCT in relation to the used swabs for sampling is really important. The use of inappropriate swabs could lead to false negative or misleading analysis results.http://link.springer.com/article/10.1186/s13568-020-00978-9POCTSwabsClinical diagnosticsSample collection
collection DOAJ
language English
format Article
sources DOAJ
author Aleksandra Anna Zasada
Katarzyna Zacharczuk
Katarzyna Woźnica
Małgorzata Główka
Robert Ziółkowski
Elżbieta Malinowska
spellingShingle Aleksandra Anna Zasada
Katarzyna Zacharczuk
Katarzyna Woźnica
Małgorzata Główka
Robert Ziółkowski
Elżbieta Malinowska
The influence of a swab type on the results of point-of-care tests
AMB Express
POCT
Swabs
Clinical diagnostics
Sample collection
author_facet Aleksandra Anna Zasada
Katarzyna Zacharczuk
Katarzyna Woźnica
Małgorzata Główka
Robert Ziółkowski
Elżbieta Malinowska
author_sort Aleksandra Anna Zasada
title The influence of a swab type on the results of point-of-care tests
title_short The influence of a swab type on the results of point-of-care tests
title_full The influence of a swab type on the results of point-of-care tests
title_fullStr The influence of a swab type on the results of point-of-care tests
title_full_unstemmed The influence of a swab type on the results of point-of-care tests
title_sort influence of a swab type on the results of point-of-care tests
publisher SpringerOpen
series AMB Express
issn 2191-0855
publishDate 2020-03-01
description Abstract Most point-of-care tests (POCT) use swabs for sampling and/or for applying a sample on the test. A variety of swabs differing in tip materials is commercially available. Different tip materials have different chemical and physical characteristics which might influence the specimen collection and release. We investigated properties of various types of swabs used in clinical diagnostics with focusing on two kinds of analytes, DNA and proteins, which are most often used targets in POCT. As the model samples we used diphtheria toxoid NIBSC 69/017 for investigating recovery of protein analytes such as antigens and bacterial strains of Escherichia coli ATCC 25922, diphtheria toxin-producing Corynebacterium diphtheriae NCTC 10648, and the clinical isolate nontoxigenic C. diphtheriae 5820/15 for investigating the recovery of nucleic acids. We investigated four types of swabs most commonly used in clinical diagnostics in terms of absorption capacity and efficiency of release of nucleic acids and proteins. Volume uptake was measured in milligrams. For DNA release various washing out buffers were used and the amount of released DNA was measured spectrophotometrically. The amount of protein released from the swabs were examined using the Lowry assay. We observed statistically significant differences (p < 0.05) in the mean weights of absorbed liquid, in the DNA recovery and protein recovery by the four variety of swab examined. However, the efficiency of DNA and protein release was not correlated to the absorbed volume of a sample, but rather to the properties of swabs. The swab composition and structure can have a significant impact on the collection and release efficiency of a sample. Therefore, validation of POCT in relation to the used swabs for sampling is really important. The use of inappropriate swabs could lead to false negative or misleading analysis results.
topic POCT
Swabs
Clinical diagnostics
Sample collection
url http://link.springer.com/article/10.1186/s13568-020-00978-9
work_keys_str_mv AT aleksandraannazasada theinfluenceofaswabtypeontheresultsofpointofcaretests
AT katarzynazacharczuk theinfluenceofaswabtypeontheresultsofpointofcaretests
AT katarzynawoznica theinfluenceofaswabtypeontheresultsofpointofcaretests
AT małgorzatagłowka theinfluenceofaswabtypeontheresultsofpointofcaretests
AT robertziołkowski theinfluenceofaswabtypeontheresultsofpointofcaretests
AT elzbietamalinowska theinfluenceofaswabtypeontheresultsofpointofcaretests
AT aleksandraannazasada influenceofaswabtypeontheresultsofpointofcaretests
AT katarzynazacharczuk influenceofaswabtypeontheresultsofpointofcaretests
AT katarzynawoznica influenceofaswabtypeontheresultsofpointofcaretests
AT małgorzatagłowka influenceofaswabtypeontheresultsofpointofcaretests
AT robertziołkowski influenceofaswabtypeontheresultsofpointofcaretests
AT elzbietamalinowska influenceofaswabtypeontheresultsofpointofcaretests
_version_ 1724924572707323904