Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent
Polystyrene (PS) thin film with various concentration of mass (1%, 3%, and 5%) has been deposited onto Quartz Crystal Microbalance (QCM) surface by a spin coating method. The purpose of this research is the improvement of Bovine Serum Albumin (BSA) immobilization into the QCM surface. The QCM reson...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
Institut Agama Islam Negeri Raden Intan Lampung
2019-04-01
|
Series: | Jurnal Ilmiah Pendidikan Fisika Al-Biruni |
Subjects: | |
Online Access: | http://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/3716 |
id |
doaj-8b51bc4558fd4adaa4c1959482c6fbf6 |
---|---|
record_format |
Article |
spelling |
doaj-8b51bc4558fd4adaa4c1959482c6fbf62020-12-29T07:24:55ZindInstitut Agama Islam Negeri Raden Intan LampungJurnal Ilmiah Pendidikan Fisika Al-Biruni2303-18322503-023X2019-04-0181354110.24042/jipfalbiruni.v8i1.37162483Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization AgentLalu A. Didik0Yahdi Yahdi1Masruroh Masruroh2Universitas Islam Negeri MataramUniversitas Islam Negeri MataramUniversitas BrawijayaPolystyrene (PS) thin film with various concentration of mass (1%, 3%, and 5%) has been deposited onto Quartz Crystal Microbalance (QCM) surface by a spin coating method. The purpose of this research is the improvement of Bovine Serum Albumin (BSA) immobilization into the QCM surface. The QCM resonance frequency has been investigated by means of Impedance Analyzer. The film thickness was calculated by the Sauerbrey equation. The surface roughness of the PS layer was observed by noncontact Topography Measuring System (TMS-1200). Calculation result using a Sauerbrey equation shows the thickness of the PS layer increases with the increasing PS concentration. The QCM/PS with 1% and 5% concentration of mass has rougher morphology and more frequency shifts caused by BSA injection compared to 3% concentration of PS.http://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/3716immobilizationpolystyrenequartz crystal microbalancesurface roughnessthin films |
collection |
DOAJ |
language |
Indonesian |
format |
Article |
sources |
DOAJ |
author |
Lalu A. Didik Yahdi Yahdi Masruroh Masruroh |
spellingShingle |
Lalu A. Didik Yahdi Yahdi Masruroh Masruroh Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent Jurnal Ilmiah Pendidikan Fisika Al-Biruni immobilization polystyrene quartz crystal microbalance surface roughness thin films |
author_facet |
Lalu A. Didik Yahdi Yahdi Masruroh Masruroh |
author_sort |
Lalu A. Didik |
title |
Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent |
title_short |
Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent |
title_full |
Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent |
title_fullStr |
Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent |
title_full_unstemmed |
Improvement QCM Quality By Polystyrene Coating and Bovine Serum Albumin as Immobilization Agent |
title_sort |
improvement qcm quality by polystyrene coating and bovine serum albumin as immobilization agent |
publisher |
Institut Agama Islam Negeri Raden Intan Lampung |
series |
Jurnal Ilmiah Pendidikan Fisika Al-Biruni |
issn |
2303-1832 2503-023X |
publishDate |
2019-04-01 |
description |
Polystyrene (PS) thin film with various concentration of mass (1%, 3%, and 5%) has been deposited onto Quartz Crystal Microbalance (QCM) surface by a spin coating method. The purpose of this research is the improvement of Bovine Serum Albumin (BSA) immobilization into the QCM surface. The QCM resonance frequency has been investigated by means of Impedance Analyzer. The film thickness was calculated by the Sauerbrey equation. The surface roughness of the PS layer was observed by noncontact Topography Measuring System (TMS-1200). Calculation result using a Sauerbrey equation shows the thickness of the PS layer increases with the increasing PS concentration. The QCM/PS with 1% and 5% concentration of mass has rougher morphology and more frequency shifts caused by BSA injection compared to 3% concentration of PS. |
topic |
immobilization polystyrene quartz crystal microbalance surface roughness thin films |
url |
http://ejournal.radenintan.ac.id/index.php/al-biruni/article/view/3716 |
work_keys_str_mv |
AT laluadidik improvementqcmqualitybypolystyrenecoatingandbovineserumalbuminasimmobilizationagent AT yahdiyahdi improvementqcmqualitybypolystyrenecoatingandbovineserumalbuminasimmobilizationagent AT masrurohmasruroh improvementqcmqualitybypolystyrenecoatingandbovineserumalbuminasimmobilizationagent |
_version_ |
1724367970827763712 |