The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences

SUMMARY OBJECTIVE: With high-resolution real-time ultrasonography we investigated the muscle architectural parameters of vastus lateralis in healthy volunteers. PURPOSES: We determined the reproducibility and validity of ultrasonography and the role of the ultrasonographer in assessing muscle arch...

Full description

Bibliographic Details
Main Authors: Rita Chiaramonte, Marco Bonfiglio, Emilio G. Castorina, Salvatore A. M. Antoci
Format: Article
Language:English
Published: Associação Médica Brasileira
Series:Revista da Associação Médica Brasileira
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302019000200165&lng=en&tlng=en
id doaj-8c90c04d7f8a4150a69571f3bce1d2a5
record_format Article
spelling doaj-8c90c04d7f8a4150a69571f3bce1d2a52020-11-24T21:51:06ZengAssociação Médica BrasileiraRevista da Associação Médica Brasileira1806-928265216517010.1590/1806-9282.65.2.165S0104-42302019000200165The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiencesRita ChiaramonteMarco BonfiglioEmilio G. CastorinaSalvatore A. M. AntociSUMMARY OBJECTIVE: With high-resolution real-time ultrasonography we investigated the muscle architectural parameters of vastus lateralis in healthy volunteers. PURPOSES: We determined the reproducibility and validity of ultrasonography and the role of the ultrasonographer in assessing muscle architecture. We proposed the most appropriate clinical parameters for objective measurements and an ultrasound protocol of muscle architecture. METHODS: We conducted an intraobserver and interobserver study. We investigated 21 healthy male volunteers. The subjects were independently evaluated by four different operators using high-resolution real-time ultrasonography. To assess the reproducibility of ultrasound examinations, four operators repeated measurements using the same ultrasound device. Muscle thickness, muscle volume, muscle fiber pennation angle, and subcutaneous adiposity of the vastus lateralis muscle were measured. RESULTS: Intra-observer (ICC 0.92-0.97), interobserver (ICC 0.78-0.92) reproducibility was good to excellent for all measurements. CONCLUSION: Simple, reproducible, non-invasive ultrasound measurements of muscle structure easily demonstrated differences in muscle morphology. With a protocol and with objective and repeatable measurements, sonographers from different backgrounds could obtain an objective measurement of ultrasound images with little differences and low variability in results, thanks to the upgrading of diagnostic ultrasound imaging and their clinical skills.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302019000200165&lng=en&tlng=enUltrasonographyQuadriceps muscleMuscle fibers, skeletal
collection DOAJ
language English
format Article
sources DOAJ
author Rita Chiaramonte
Marco Bonfiglio
Emilio G. Castorina
Salvatore A. M. Antoci
spellingShingle Rita Chiaramonte
Marco Bonfiglio
Emilio G. Castorina
Salvatore A. M. Antoci
The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences
Revista da Associação Médica Brasileira
Ultrasonography
Quadriceps muscle
Muscle fibers, skeletal
author_facet Rita Chiaramonte
Marco Bonfiglio
Emilio G. Castorina
Salvatore A. M. Antoci
author_sort Rita Chiaramonte
title The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences
title_short The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences
title_full The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences
title_fullStr The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences
title_full_unstemmed The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences
title_sort primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. physiatrist, radiologist, general internist, and family practitioner's experiences
publisher Associação Médica Brasileira
series Revista da Associação Médica Brasileira
issn 1806-9282
description SUMMARY OBJECTIVE: With high-resolution real-time ultrasonography we investigated the muscle architectural parameters of vastus lateralis in healthy volunteers. PURPOSES: We determined the reproducibility and validity of ultrasonography and the role of the ultrasonographer in assessing muscle architecture. We proposed the most appropriate clinical parameters for objective measurements and an ultrasound protocol of muscle architecture. METHODS: We conducted an intraobserver and interobserver study. We investigated 21 healthy male volunteers. The subjects were independently evaluated by four different operators using high-resolution real-time ultrasonography. To assess the reproducibility of ultrasound examinations, four operators repeated measurements using the same ultrasound device. Muscle thickness, muscle volume, muscle fiber pennation angle, and subcutaneous adiposity of the vastus lateralis muscle were measured. RESULTS: Intra-observer (ICC 0.92-0.97), interobserver (ICC 0.78-0.92) reproducibility was good to excellent for all measurements. CONCLUSION: Simple, reproducible, non-invasive ultrasound measurements of muscle structure easily demonstrated differences in muscle morphology. With a protocol and with objective and repeatable measurements, sonographers from different backgrounds could obtain an objective measurement of ultrasound images with little differences and low variability in results, thanks to the upgrading of diagnostic ultrasound imaging and their clinical skills.
topic Ultrasonography
Quadriceps muscle
Muscle fibers, skeletal
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302019000200165&lng=en&tlng=en
work_keys_str_mv AT ritachiaramonte theprimacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT marcobonfiglio theprimacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT emiliogcastorina theprimacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT salvatoreamantoci theprimacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT ritachiaramonte primacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT marcobonfiglio primacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT emiliogcastorina primacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
AT salvatoreamantoci primacyofultrasoundintheassessmentofmusclearchitectureprecisionaccuracyreliabilityofultrasonographyphysiatristradiologistgeneralinternistandfamilypractitionersexperiences
_version_ 1725880381839769600