Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?

Peter Kjeldgaard,1 Jesper Lykkegaard,2 Heidi Spillemose,3 Charlotte Suppli Ulrik1,4 1Department of Respiratory Medicine, Hvidovre Hospital, Hvidovre, 2Research Unit of General Practice, University of Southern Denmark, Odense, 3General Practice Aarup Lægerne, Aarup, 4Institute of Clinical...

Full description

Bibliographic Details
Main Authors: Kjeldgaard P, Lykkegaard J, Spillemose H, Ulrik CS
Format: Article
Language:English
Published: Dove Medical Press 2017-08-01
Series:International Journal of COPD
Subjects:
Online Access:https://www.dovepress.com/multicenter-study-of-the-copd-6-screening-device-feasible-for-early-de-peer-reviewed-article-COPD
id doaj-8d07790181d2430584ba8459ff61b7ba
record_format Article
spelling doaj-8d07790181d2430584ba8459ff61b7ba2020-11-24T22:12:26ZengDove Medical PressInternational Journal of COPD1178-20052017-08-01Volume 122323233134111Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?Kjeldgaard PLykkegaard JSpillemose HUlrik CSPeter Kjeldgaard,1 Jesper Lykkegaard,2 Heidi Spillemose,3 Charlotte Suppli Ulrik1,4 1Department of Respiratory Medicine, Hvidovre Hospital, Hvidovre, 2Research Unit of General Practice, University of Southern Denmark, Odense, 3General Practice Aarup Lægerne, Aarup, 4Institute of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark Background and aim: Early detection of COPD may reduce the future burden of the disease. We aimed to investigate whether prescreening with a COPD-6 screening device (measuring FEV1 and FEV6) facilitates early detection of COPD in primary care. Methods: In primary care, individuals at high risk of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV1/FEV6 <0.7, FEV1 <80%pred, or clinical suspicion of COPD regardless of test result (medical doctor’s [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV1/FVC <0.70), asthma (ΔFEV1 ≥0.50 L), or no obstructive lung disease.Results: A total of 2,990 subjects (54% men, mean age 59 years, and mean 28 pack-years) were enrolled, of whom 949 (32%) proceeded from COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV1/FEV6 <0.70, 382 (40%) FEV1 <80%pred, and 57 (6%) MD decision. Following confirmative spirometry, the 949 individuals were diagnosed as having COPD (51%), asthma (3%), and no obstructive lung disease (45%). COPD was diagnosed in 487 (16%) of the enrolled subjects in whom confirmative spirometry was performed in 69% based on FEV1/FEV6 <0.7 and in 29% based on FEV1 ≤80%pred.Conclusion: Prescreening with the COPD-6 device showed acceptable specificity for the selection of subjects for diagnostic spirometry and is likely to be a useful alternative to current practice in primary care. Keywords: early COPD, diagnosis, spirometry, general practice https://www.dovepress.com/multicenter-study-of-the-copd-6-screening-device-feasible-for-early-de-peer-reviewed-article-COPDEarly COPDdiagnosisspirometrygeneral practice
collection DOAJ
language English
format Article
sources DOAJ
author Kjeldgaard P
Lykkegaard J
Spillemose H
Ulrik CS
spellingShingle Kjeldgaard P
Lykkegaard J
Spillemose H
Ulrik CS
Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
International Journal of COPD
Early COPD
diagnosis
spirometry
general practice
author_facet Kjeldgaard P
Lykkegaard J
Spillemose H
Ulrik CS
author_sort Kjeldgaard P
title Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
title_short Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
title_full Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
title_fullStr Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
title_full_unstemmed Multicenter study of the COPD-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
title_sort multicenter study of the copd-6 screening device: feasible for early detection of chronic obstructive pulmonary disease in primary care?
publisher Dove Medical Press
series International Journal of COPD
issn 1178-2005
publishDate 2017-08-01
description Peter Kjeldgaard,1 Jesper Lykkegaard,2 Heidi Spillemose,3 Charlotte Suppli Ulrik1,4 1Department of Respiratory Medicine, Hvidovre Hospital, Hvidovre, 2Research Unit of General Practice, University of Southern Denmark, Odense, 3General Practice Aarup Lægerne, Aarup, 4Institute of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark Background and aim: Early detection of COPD may reduce the future burden of the disease. We aimed to investigate whether prescreening with a COPD-6 screening device (measuring FEV1 and FEV6) facilitates early detection of COPD in primary care. Methods: In primary care, individuals at high risk of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV1/FEV6 <0.7, FEV1 <80%pred, or clinical suspicion of COPD regardless of test result (medical doctor’s [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV1/FVC <0.70), asthma (ΔFEV1 ≥0.50 L), or no obstructive lung disease.Results: A total of 2,990 subjects (54% men, mean age 59 years, and mean 28 pack-years) were enrolled, of whom 949 (32%) proceeded from COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV1/FEV6 <0.70, 382 (40%) FEV1 <80%pred, and 57 (6%) MD decision. Following confirmative spirometry, the 949 individuals were diagnosed as having COPD (51%), asthma (3%), and no obstructive lung disease (45%). COPD was diagnosed in 487 (16%) of the enrolled subjects in whom confirmative spirometry was performed in 69% based on FEV1/FEV6 <0.7 and in 29% based on FEV1 ≤80%pred.Conclusion: Prescreening with the COPD-6 device showed acceptable specificity for the selection of subjects for diagnostic spirometry and is likely to be a useful alternative to current practice in primary care. Keywords: early COPD, diagnosis, spirometry, general practice 
topic Early COPD
diagnosis
spirometry
general practice
url https://www.dovepress.com/multicenter-study-of-the-copd-6-screening-device-feasible-for-early-de-peer-reviewed-article-COPD
work_keys_str_mv AT kjeldgaardp multicenterstudyofthecopd6screeningdevicefeasibleforearlydetectionofchronicobstructivepulmonarydiseaseinprimarycare
AT lykkegaardj multicenterstudyofthecopd6screeningdevicefeasibleforearlydetectionofchronicobstructivepulmonarydiseaseinprimarycare
AT spillemoseh multicenterstudyofthecopd6screeningdevicefeasibleforearlydetectionofchronicobstructivepulmonarydiseaseinprimarycare
AT ulrikcs multicenterstudyofthecopd6screeningdevicefeasibleforearlydetectionofchronicobstructivepulmonarydiseaseinprimarycare
_version_ 1725803739199045632