Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
AIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2017-03-01
|
Series: | International Journal of Ophthalmology |
Subjects: | |
Online Access: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360783/ |
id |
doaj-8e565d9229a34b23968fdf91e6b06cbd |
---|---|
record_format |
Article |
spelling |
doaj-8e565d9229a34b23968fdf91e6b06cbd2020-11-24T21:23:38ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982017-03-0110345346010.18240/ijo.2017.03.20Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreementRachele R. Penna0Ugo de Sanctis1Martina Catalano2Luca Brusasco3Federico M. Grignolo4Department of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyAIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS: One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS: In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. CONCLUSION: As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360783/keratoconuspost-LASIKcorneal power measurementPlacido disk-based topographyScheimpflug cameraScheimpflug camera |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Rachele R. Penna Ugo de Sanctis Martina Catalano Luca Brusasco Federico M. Grignolo |
spellingShingle |
Rachele R. Penna Ugo de Sanctis Martina Catalano Luca Brusasco Federico M. Grignolo Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement International Journal of Ophthalmology keratoconus post-LASIK corneal power measurement Placido disk-based topography Scheimpflug camera Scheimpflug camera |
author_facet |
Rachele R. Penna Ugo de Sanctis Martina Catalano Luca Brusasco Federico M. Grignolo |
author_sort |
Rachele R. Penna |
title |
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement |
title_short |
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement |
title_full |
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement |
title_fullStr |
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement |
title_full_unstemmed |
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement |
title_sort |
placido disk-based topography versus high-resolution rotating scheimpflug camera for corneal power measurements in keratoconic and post-lasik eyes: reliability and agreement |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
International Journal of Ophthalmology |
issn |
2222-3959 2227-4898 |
publishDate |
2017-03-01 |
description |
AIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK).
METHODS: One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA).
RESULTS: In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf.
CONCLUSION: As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes. |
topic |
keratoconus post-LASIK corneal power measurement Placido disk-based topography Scheimpflug camera Scheimpflug camera |
url |
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360783/ |
work_keys_str_mv |
AT rachelerpenna placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement AT ugodesanctis placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement AT martinacatalano placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement AT lucabrusasco placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement AT federicomgrignolo placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement |