Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement

AIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ...

Full description

Bibliographic Details
Main Authors: Rachele R. Penna, Ugo de Sanctis, Martina Catalano, Luca Brusasco, Federico M. Grignolo
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2017-03-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360783/
id doaj-8e565d9229a34b23968fdf91e6b06cbd
record_format Article
spelling doaj-8e565d9229a34b23968fdf91e6b06cbd2020-11-24T21:23:38ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982017-03-0110345346010.18240/ijo.2017.03.20Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreementRachele R. Penna0Ugo de Sanctis1Martina Catalano2Luca Brusasco3Federico M. Grignolo4Department of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyDepartment of Surgical Sciences, Eye Clinic, University of Torino, Via Juvarra 19, Torino 10122, ItalyAIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS: One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS: In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. CONCLUSION: As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360783/keratoconuspost-LASIKcorneal power measurementPlacido disk-based topographyScheimpflug cameraScheimpflug camera
collection DOAJ
language English
format Article
sources DOAJ
author Rachele R. Penna
Ugo de Sanctis
Martina Catalano
Luca Brusasco
Federico M. Grignolo
spellingShingle Rachele R. Penna
Ugo de Sanctis
Martina Catalano
Luca Brusasco
Federico M. Grignolo
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
International Journal of Ophthalmology
keratoconus
post-LASIK
corneal power measurement
Placido disk-based topography
Scheimpflug camera
Scheimpflug camera
author_facet Rachele R. Penna
Ugo de Sanctis
Martina Catalano
Luca Brusasco
Federico M. Grignolo
author_sort Rachele R. Penna
title Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
title_short Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
title_full Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
title_fullStr Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
title_full_unstemmed Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement
title_sort placido disk-based topography versus high-resolution rotating scheimpflug camera for corneal power measurements in keratoconic and post-lasik eyes: reliability and agreement
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series International Journal of Ophthalmology
issn 2222-3959
2227-4898
publishDate 2017-03-01
description AIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS: One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS: In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. CONCLUSION: As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.
topic keratoconus
post-LASIK
corneal power measurement
Placido disk-based topography
Scheimpflug camera
Scheimpflug camera
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5360783/
work_keys_str_mv AT rachelerpenna placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement
AT ugodesanctis placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement
AT martinacatalano placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement
AT lucabrusasco placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement
AT federicomgrignolo placidodiskbasedtopographyversushighresolutionrotatingscheimpflugcameraforcornealpowermeasurementsinkeratoconicandpostlasikeyesreliabilityandagreement
_version_ 1725991917241499648