Comparison of the Supreme™ and ProSeal™ laryngeal mask airways in infants: a prospective randomised clinical study

Abstract Background The Supreme™ and ProSeal™ laryngeal mask airways (LMAs) are widely used in paediatric anaesthesia; however, LMA use in infants is limited because many anaesthesiologists prefer to use tracheal intubation in infants. In this study, we compared the Supreme and ProSeal LMAs in infan...

Full description

Bibliographic Details
Main Authors: Sibel Oba, Hacer Sebnem Turk, Canan Tulay Isil, Huseyin Erdogan, Pinar Sayin, Ali Ihsan Dokucu
Format: Article
Language:English
Published: BMC 2017-09-01
Series:BMC Anesthesiology
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12871-017-0418-z
Description
Summary:Abstract Background The Supreme™ and ProSeal™ laryngeal mask airways (LMAs) are widely used in paediatric anaesthesia; however, LMA use in infants is limited because many anaesthesiologists prefer to use tracheal intubation in infants. In this study, we compared the Supreme and ProSeal LMAs in infants by measuring their performance characteristics, including insertion features, ventilation parameters, induced changes in haemodynamics and rates of postoperative complications. Methods Infants of ASA physical status I scheduled for elective, minor, lower abdominal surgery were divided into two groups: the Supreme LMA group and the ProSeal LMA group. Times and ease of LMA insertion were noted. The percentages of tidal volume leakage as well as peak, mean and leakage pressures for all infants were measured. Heart rate (HR), oxygen saturation (SpO2) and end tidal carbon dioxide (EtCO2) values were recorded before and after LMA insertion and before and after extubation. After extubation, complications and adverse effects were noted. Results Demographic and surgical data were similar between the two groups. LMA insertion times were shorter for the ProSeal group than for the Supreme group (P < 0.002). The mean HR value for the ProSeal group was lower than for the Supreme group (P < 0.011). Both the peak pressure and the leakage percentage for the ProSeal group were statistically lower than for the Supreme group. The leakage pressure for the ProSeal group was statistically higher than for the Supreme group (P < 0.001). Conclusions The ProSeal LMA is superior to the Supreme LMA for use in infants due to the ease of insertion, high oropharyngeal leakage pressure and fewer induced changes in haemodynamics. Trial registration ClinicalTrial.gov, NCT03251105 , retrospectively registered on 15 Aug 2017.
ISSN:1471-2253