Insulation co-ordination and the enlargement law for the GM counter tube

In this paper we analyze application of contemporary methods of insulation co-ordination and the enlargement law in designing a GM counting tube. It has been shown that by applying insulation co-ordination methods the counting tube can be optimally dimensioned. The application of the enlarg...

Full description

Bibliographic Details
Main Authors: Dolićanin Edin Ć., Fetahović Irfan S., Lazarević Đorđe R., Kartalović Nenad M.
Format: Article
Language:English
Published: VINCA Institute of Nuclear Sciences 2016-01-01
Series:Nuclear Technology and Radiation Protection
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1451-3994/2016/1451-39941602159D.pdf
Description
Summary:In this paper we analyze application of contemporary methods of insulation co-ordination and the enlargement law in designing a GM counting tube. It has been shown that by applying insulation co-ordination methods the counting tube can be optimally dimensioned. The application of the enlargement law was demonstrated in generalizing the results of test obtained by the GM tube to those obtained by the counting tube with m-times greater dimensions. The investigations were conducted both theoretically and by experiment. Using theoretical analysis, we derived the expressions that may be applied if a performance function of a random variable breakdown voltage is known. The experiments were conducted on a GM counter model under well controlled laboratory conditions.
ISSN:1451-3994
1452-8185