Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion

Changavi F1, janani F1, Asti P1, Akbari S2 1. Instructor, Department of midwifery, Faculty of nursing and midwifery, Lorestan University of Medical Sciences 2. Instructor, Department of gynecology, Faculty of medicine, Lorestan University of Medical Sciences Abstract Background: IUD is a us...

Full description

Bibliographic Details
Main Authors: farahnaz Changavi, fatemeh janani, parvin Asti, soheila Akbari
Format: Article
Language:fas
Published: Lorestan University of Medical Science 2007-04-01
Series:Yafteh
Subjects:
Online Access:http://yafte.lums.ac.ir/browse.php?a_code=A-10-1-198&slc_lang=en&sid=1
id doaj-8ff3ec4eb40246aca07e62c5e05df02d
record_format Article
spelling doaj-8ff3ec4eb40246aca07e62c5e05df02d2020-11-25T01:24:49ZfasLorestan University of Medical ScienceYafteh1563-07732007-04-01915762Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertionfarahnaz Changavi0fatemeh janani1parvin Asti2soheila Akbari3 Changavi F1, janani F1, Asti P1, Akbari S2 1. Instructor, Department of midwifery, Faculty of nursing and midwifery, Lorestan University of Medical Sciences 2. Instructor, Department of gynecology, Faculty of medicine, Lorestan University of Medical Sciences Abstract Background: IUD is a useful and effective tool for family planning. Different kinds of this equipment are available at the market, but currently the most commonly used one in our country is CU T380A. Previous studies have shown that CU safe 300 is more effective and associated with less complications than CU t380A, thus it is more acceptable by users. The aim of this study was to determine and compare failure rate of CU T380A and CU safe 300 IUDS, four years after insertion. Materials and methods: The present research is a cohort study carried out on 246 women who referred to health clinics of Khorramabad four years ago. These women divided into two equal groups. One group used CU T380A and the other group used CU safe 300. The rate of unwanted delayed complications such as spontaneous bleeding, pregnancy and spontaneous repelling of the IUDs were assessed by a questionnaire. Data were analyzed by Chi square and paired T test. Results: Failure rate of CU T380A was more than CU safe 300. Statistical tests showed significant differences between these two groups. Conclusion: This study shows that new IUD (CU safe 300 ) which are smaller in size have less Failure rate and more acceptable by women, so their use is suggested in health clinics. Key words:http://yafte.lums.ac.ir/browse.php?a_code=A-10-1-198&slc_lang=en&sid=1CU T380A CU safe 300 IUD failure rate.
collection DOAJ
language fas
format Article
sources DOAJ
author farahnaz Changavi
fatemeh janani
parvin Asti
soheila Akbari
spellingShingle farahnaz Changavi
fatemeh janani
parvin Asti
soheila Akbari
Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
Yafteh
CU T380A
CU safe 300
IUD failure rate.
author_facet farahnaz Changavi
fatemeh janani
parvin Asti
soheila Akbari
author_sort farahnaz Changavi
title Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
title_short Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
title_full Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
title_fullStr Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
title_full_unstemmed Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
title_sort comparison of failure rates of cu t 380 a and cu safe 300 iuds four years after insertion
publisher Lorestan University of Medical Science
series Yafteh
issn 1563-0773
publishDate 2007-04-01
description Changavi F1, janani F1, Asti P1, Akbari S2 1. Instructor, Department of midwifery, Faculty of nursing and midwifery, Lorestan University of Medical Sciences 2. Instructor, Department of gynecology, Faculty of medicine, Lorestan University of Medical Sciences Abstract Background: IUD is a useful and effective tool for family planning. Different kinds of this equipment are available at the market, but currently the most commonly used one in our country is CU T380A. Previous studies have shown that CU safe 300 is more effective and associated with less complications than CU t380A, thus it is more acceptable by users. The aim of this study was to determine and compare failure rate of CU T380A and CU safe 300 IUDS, four years after insertion. Materials and methods: The present research is a cohort study carried out on 246 women who referred to health clinics of Khorramabad four years ago. These women divided into two equal groups. One group used CU T380A and the other group used CU safe 300. The rate of unwanted delayed complications such as spontaneous bleeding, pregnancy and spontaneous repelling of the IUDs were assessed by a questionnaire. Data were analyzed by Chi square and paired T test. Results: Failure rate of CU T380A was more than CU safe 300. Statistical tests showed significant differences between these two groups. Conclusion: This study shows that new IUD (CU safe 300 ) which are smaller in size have less Failure rate and more acceptable by women, so their use is suggested in health clinics. Key words:
topic CU T380A
CU safe 300
IUD failure rate.
url http://yafte.lums.ac.ir/browse.php?a_code=A-10-1-198&slc_lang=en&sid=1
work_keys_str_mv AT farahnazchangavi comparisonoffailureratesofcut380aandcusafe300iudsfouryearsafterinsertion
AT fatemehjanani comparisonoffailureratesofcut380aandcusafe300iudsfouryearsafterinsertion
AT parvinasti comparisonoffailureratesofcut380aandcusafe300iudsfouryearsafterinsertion
AT soheilaakbari comparisonoffailureratesofcut380aandcusafe300iudsfouryearsafterinsertion
_version_ 1725116925860642816