First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America

Objective. To compare the performance of polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA) tests for diagnosing Echinococcus granulosus in dog feces among national reference laboratories in Argentina, Chile, Peru, and Uruguay. Methods. National laboratories affiliated wit...

Full description

Bibliographic Details
Main Authors: María Isabel Jercic, Graciela Santillan, Susana Elola, William Quispe Paredes, Lidia B. Conza Blanco, Noelia Morel, Rodrigo Villegas, Baldomero Molina Flores, Cesar M. Gavidia, Marta Cabrera, Alexandre Guerra dos Santos, Manuel J. Sanchez-Vazquez, Melody J. Maxwell, Marco A. Vigilato, Edmundo Larrieu, Víctor J. Del Rio Vilas
Format: Article
Language:English
Published: Pan American Health Organization 2019-12-01
Series:Revista Panamericana de Salud Pública
Subjects:
Online Access:http://iris.paho.org/xmlui/handle/123456789/51732
id doaj-90a3e80e5d394ea7ba8028e0a59e30a2
record_format Article
spelling doaj-90a3e80e5d394ea7ba8028e0a59e30a22020-11-24T21:56:34ZengPan American Health OrganizationRevista Panamericana de Salud Pública1020-49891680-53482019-12-014311710.26633/RPSP.2019.89rpspFirst inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin AmericaMaría Isabel Jercic0Graciela Santillan1Susana Elola2William Quispe Paredes3Lidia B. Conza Blanco4Noelia Morel5Rodrigo Villegas6Baldomero Molina Flores7Cesar M. Gavidia8Marta Cabrera9Alexandre Guerra dos Santos10Manuel J. Sanchez-Vazquez11Melody J. Maxwell12Marco A. Vigilato13Edmundo Larrieu14Víctor J. Del Rio Vilas15Instituto de Salud Pública de Chile, Santiago de Chile, ChileInstituto Nacional de Enfermedades Infecciosas “Carlos G. Malbran,” Buenos Aires, ArgentinaComisión Nacional de Zoonosis, Montevideo, UruguayInstituto Nacional de Salud, Lima, PeruServicio Nacional de Sanidad Agraria, Lima, PeruComisión Nacional de Zoonosis, Montevideo, UruguayInstituto de Salud Pública de Chile, Santiago de Chile, ChileCentro Panamericano de Fiebre Aftosa, Pan American Health Organization (PAHO) / World Health Organization (WHO), Rio de Janeiro, BrazilFacultad de Medicina Veterinaria, Universidad Nacional Mayor de San Marcos, Lima, PeruInstituto Nacional de Enfermedades Infecciosas “Carlos G. Malbran,” Buenos Aires, ArgentinaCentro Panamericano de Fiebre Aftosa, Pan American Health Organization (PAHO) / World Health Organization (WHO), Rio de Janeiro, BrazilCentro Panamericano de Fiebre Aftosa, Pan American Health Organization (PAHO) / World Health Organization (WHO), Rio de Janeiro, BrazilThe Ohio State University, Columbus, Ohio, United States of AmericaPAHO/WHO Country Office, San Salvador, El SalvadorEscuela de Veterinaria, Universidad Nacional de Rio Negro, Choele Choel, ArgentinaSchool of Veterinary Medicine, University of Surrey, Surrey, United KingdomObjective. To compare the performance of polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA) tests for diagnosing Echinococcus granulosus in dog feces among national reference laboratories in Argentina, Chile, Peru, and Uruguay. Methods. National laboratories affiliated with the Ministry of Health/Agriculture of each country exchanged panels of 10 positive/negative samples obtained from their regular national surveillance programs in November 2015 – November 2016. All laboratories applied PCR; two also applied ELISA techniques. Sensitivity and specificity were determined for each laboratory and concordance of results among the laboratories was evaluated by Cohen Kappa coefficient. Results. Poor concordance (3 of 10 paired comparisons had values of Kappa > 0.4), low sensitivity and specificity across all laboratories, and poor performance of both techniques in detecting E. granulosus in canine feces was demonstrated in this study. An ex-post comparison of the laboratories’ test protocols showed substantial heterogeneity that could partially explain poor concordance of results. Conclusion. The results underscore the heterogeneity of canine echinococcosis diagnosis across the region and indicate possible sources of variability. Efforts to standardize canine echinococcosis testing must be included in the plan of action for the Regional Initiative for the Control of Cystic Echinococcosis. Future comparisons with fecal samples of known parasite load are needed.http://iris.paho.org/xmlui/handle/123456789/51732echinococcosisdog diseaseslaboratory proficiency testingsouth america
collection DOAJ
language English
format Article
sources DOAJ
author María Isabel Jercic
Graciela Santillan
Susana Elola
William Quispe Paredes
Lidia B. Conza Blanco
Noelia Morel
Rodrigo Villegas
Baldomero Molina Flores
Cesar M. Gavidia
Marta Cabrera
Alexandre Guerra dos Santos
Manuel J. Sanchez-Vazquez
Melody J. Maxwell
Marco A. Vigilato
Edmundo Larrieu
Víctor J. Del Rio Vilas
spellingShingle María Isabel Jercic
Graciela Santillan
Susana Elola
William Quispe Paredes
Lidia B. Conza Blanco
Noelia Morel
Rodrigo Villegas
Baldomero Molina Flores
Cesar M. Gavidia
Marta Cabrera
Alexandre Guerra dos Santos
Manuel J. Sanchez-Vazquez
Melody J. Maxwell
Marco A. Vigilato
Edmundo Larrieu
Víctor J. Del Rio Vilas
First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America
Revista Panamericana de Salud Pública
echinococcosis
dog diseases
laboratory proficiency testing
south america
author_facet María Isabel Jercic
Graciela Santillan
Susana Elola
William Quispe Paredes
Lidia B. Conza Blanco
Noelia Morel
Rodrigo Villegas
Baldomero Molina Flores
Cesar M. Gavidia
Marta Cabrera
Alexandre Guerra dos Santos
Manuel J. Sanchez-Vazquez
Melody J. Maxwell
Marco A. Vigilato
Edmundo Larrieu
Víctor J. Del Rio Vilas
author_sort María Isabel Jercic
title First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America
title_short First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America
title_full First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America
title_fullStr First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America
title_full_unstemmed First inter-laboratory comparison of Echinococcus granulosus sensu lato diagnosis in Latin America
title_sort first inter-laboratory comparison of echinococcus granulosus sensu lato diagnosis in latin america
publisher Pan American Health Organization
series Revista Panamericana de Salud Pública
issn 1020-4989
1680-5348
publishDate 2019-12-01
description Objective. To compare the performance of polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA) tests for diagnosing Echinococcus granulosus in dog feces among national reference laboratories in Argentina, Chile, Peru, and Uruguay. Methods. National laboratories affiliated with the Ministry of Health/Agriculture of each country exchanged panels of 10 positive/negative samples obtained from their regular national surveillance programs in November 2015 – November 2016. All laboratories applied PCR; two also applied ELISA techniques. Sensitivity and specificity were determined for each laboratory and concordance of results among the laboratories was evaluated by Cohen Kappa coefficient. Results. Poor concordance (3 of 10 paired comparisons had values of Kappa > 0.4), low sensitivity and specificity across all laboratories, and poor performance of both techniques in detecting E. granulosus in canine feces was demonstrated in this study. An ex-post comparison of the laboratories’ test protocols showed substantial heterogeneity that could partially explain poor concordance of results. Conclusion. The results underscore the heterogeneity of canine echinococcosis diagnosis across the region and indicate possible sources of variability. Efforts to standardize canine echinococcosis testing must be included in the plan of action for the Regional Initiative for the Control of Cystic Echinococcosis. Future comparisons with fecal samples of known parasite load are needed.
topic echinococcosis
dog diseases
laboratory proficiency testing
south america
url http://iris.paho.org/xmlui/handle/123456789/51732
work_keys_str_mv AT mariaisabeljercic firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT gracielasantillan firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT susanaelola firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT williamquispeparedes firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT lidiabconzablanco firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT noeliamorel firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT rodrigovillegas firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT baldomeromolinaflores firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT cesarmgavidia firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT martacabrera firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT alexandreguerradossantos firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT manueljsanchezvazquez firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT melodyjmaxwell firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT marcoavigilato firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT edmundolarrieu firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
AT victorjdelriovilas firstinterlaboratorycomparisonofechinococcusgranulosussensulatodiagnosisinlatinamerica
_version_ 1725858345120694272