Achieving High Input PF for CRM Buck-Buck/Boost PFC Converter

When the on-time is constant during a line cycle, the input power factor (PF) of critical conduction mode buck-buck/boost power factor correction converter is low. A variable on-time control (VOTC) scheme is put forward in this paper to realize high PF. By utilizing the input and output voltage to m...

Full description

Bibliographic Details
Main Authors: Abdul Hakeem Memon, Mazhar Hussain Baloach, Anwar Ali Sahito, Amir Mahmood Soomro, Zubair Ahmed Memon
Format: Article
Language:English
Published: IEEE 2018-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8573577/
Description
Summary:When the on-time is constant during a line cycle, the input power factor (PF) of critical conduction mode buck-buck/boost power factor correction converter is low. A variable on-time control (VOTC) scheme is put forward in this paper to realize high PF. By utilizing the input and output voltage to modulate the on-time of buck and buck/boost switch, we can realize high-input PF with low-total harmonic distortion within the universal input voltage range. The operating principles and the comparative analysis of the converter with conventional constant on-time control (COTC) and VOTC are analyzed. The proposed control scheme achieves high PF and efficiency as compared with the COTC. A 100-W prototype was built up to verify the effectiveness of the proposed control strategy.
ISSN:2169-3536