Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitabl...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2008-04-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/8/4/2331/ |
id |
doaj-93531dde9923450daa8899b68814f4fd |
---|---|
record_format |
Article |
spelling |
doaj-93531dde9923450daa8899b68814f4fd2020-11-24T21:08:02ZengMDPI AGSensors1424-82202008-04-018423312412Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past DecadeMohammad Reza GanjaliRassoul DinarvandParviz NorouziFarnoush FaridbodMany research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed.http://www.mdpi.com/1424-8220/8/4/2331/Conducting polymersensorion selective electrodesnon-conducting polymerpotentiometric membrane sensor |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mohammad Reza Ganjali Rassoul Dinarvand Parviz Norouzi Farnoush Faridbod |
spellingShingle |
Mohammad Reza Ganjali Rassoul Dinarvand Parviz Norouzi Farnoush Faridbod Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade Sensors Conducting polymer sensor ion selective electrodes non-conducting polymer potentiometric membrane sensor |
author_facet |
Mohammad Reza Ganjali Rassoul Dinarvand Parviz Norouzi Farnoush Faridbod |
author_sort |
Mohammad Reza Ganjali |
title |
Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade |
title_short |
Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade |
title_full |
Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade |
title_fullStr |
Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade |
title_full_unstemmed |
Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade |
title_sort |
developments in the field of conducting and non-conducting polymer based potentiometric membrane sensors for ions over the past decade |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2008-04-01 |
description |
Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed. |
topic |
Conducting polymer sensor ion selective electrodes non-conducting polymer potentiometric membrane sensor |
url |
http://www.mdpi.com/1424-8220/8/4/2331/ |
work_keys_str_mv |
AT mohammadrezaganjali developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade AT rassouldinarvand developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade AT parviznorouzi developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade AT farnoushfaridbod developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade |
_version_ |
1716761154070511616 |