Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitabl...

Full description

Bibliographic Details
Main Authors: Mohammad Reza Ganjali, Rassoul Dinarvand, Parviz Norouzi, Farnoush Faridbod
Format: Article
Language:English
Published: MDPI AG 2008-04-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/8/4/2331/
id doaj-93531dde9923450daa8899b68814f4fd
record_format Article
spelling doaj-93531dde9923450daa8899b68814f4fd2020-11-24T21:08:02ZengMDPI AGSensors1424-82202008-04-018423312412Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past DecadeMohammad Reza GanjaliRassoul DinarvandParviz NorouziFarnoush FaridbodMany research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed.http://www.mdpi.com/1424-8220/8/4/2331/Conducting polymersensorion selective electrodesnon-conducting polymerpotentiometric membrane sensor
collection DOAJ
language English
format Article
sources DOAJ
author Mohammad Reza Ganjali
Rassoul Dinarvand
Parviz Norouzi
Farnoush Faridbod
spellingShingle Mohammad Reza Ganjali
Rassoul Dinarvand
Parviz Norouzi
Farnoush Faridbod
Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
Sensors
Conducting polymer
sensor
ion selective electrodes
non-conducting polymer
potentiometric membrane sensor
author_facet Mohammad Reza Ganjali
Rassoul Dinarvand
Parviz Norouzi
Farnoush Faridbod
author_sort Mohammad Reza Ganjali
title Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
title_short Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
title_full Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
title_fullStr Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
title_full_unstemmed Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade
title_sort developments in the field of conducting and non-conducting polymer based potentiometric membrane sensors for ions over the past decade
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2008-04-01
description Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed.
topic Conducting polymer
sensor
ion selective electrodes
non-conducting polymer
potentiometric membrane sensor
url http://www.mdpi.com/1424-8220/8/4/2331/
work_keys_str_mv AT mohammadrezaganjali developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade
AT rassouldinarvand developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade
AT parviznorouzi developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade
AT farnoushfaridbod developmentsinthefieldofconductingandnonconductingpolymerbasedpotentiometricmembranesensorsforionsoverthepastdecade
_version_ 1716761154070511616