Association of compliance of ventilator bundle with incidence of ventilator-associated pneumonia and ventilator utilization among critical patients over 4 years

Background: Several studies showed that the implementation of the Institute for Healthcare Improvement (IHI) ventilator bundle alone or with other preventive measures are associated with reducing Ventilator-Associated Pneumonia (VAP) rates. However, the association with ventilator utilization was ra...

Full description

Bibliographic Details
Main Authors: Majid S Al-Thaqafy, Aiman El-Saed, Yaseen M Arabi, Hanan H Balkhy
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2014-01-01
Series:Annals of Thoracic Medicine
Subjects:
Online Access:http://www.thoracicmedicine.org/article.asp?issn=1817-1737;year=2014;volume=9;issue=4;spage=221;epage=226;aulast=Al-Thaqafy
Description
Summary:Background: Several studies showed that the implementation of the Institute for Healthcare Improvement (IHI) ventilator bundle alone or with other preventive measures are associated with reducing Ventilator-Associated Pneumonia (VAP) rates. However, the association with ventilator utilization was rarely examined and the findings were conflicting. The objectives were to validate the bundle association with VAP rate in a traditionally high VAP environment and to examine its association with ventilator utilization. Materials and Methods: The study was conducted at the adult medical-surgical intensive care unit (ICU) at King Abdulaziz Medical City, Saudi Arabia, between 2010 and 2013. VAP data were collected by a prospective targeted surveillance as per Centers for Disease Control and Prevention (CDC)/National Healthcare Safety Network (NHSN) methodology while bundle data were collected by a cross-sectional design as per IHI methodology. Results: Ventilator bundle compliance significantly increased from 90% in 2010 to 97% in 2013 (P for trend < 0.001). On the other hand, VAP rate decreased from 3.6 (per 1000 ventilator days) in 2010 to 1.0 in 2013 (P for trend = 0.054) and ventilator utilization ratio decreased from 0.73 in 2010 to 0.59 in 2013 (P for trend < 0.001). There were negative significant correlations between the trends of ventilator bundle compliance and VAP rate (cross-correlation coefficients −0.63 to 0.07) and ventilator utilization (cross-correlation coefficients −0.18 to −0.63). Conclusion: More than 70% improvement of VAP rates and approximately 20% improvement of ventilator utilization were observed during IHI ventilator bundle implementation among adult critical patients in a tertiary care center in Saudi Arabia. Replicating the current finding in multicenter randomized trials is required before establishing any causal link.
ISSN:1817-1737
1998-3557