The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia

Background: Culture remains the diagnostic standard for Streptococcus pneumoniae bacteraemia but is limited by time to identification, prior antibiotics and bacterial autolysis. Culture-independent methods for detecting S. pneumoniae include PCR and antigen tests. We evaluated an antigen test on blo...

Full description

Bibliographic Details
Main Authors: Hafsah D. Tootla, Colleen Bamford, Chad M. Centner, Clinton Moodley
Format: Article
Language:English
Published: AOSIS 2021-04-01
Series:Southern African Journal of Infectious Diseases
Subjects:
Online Access:https://sajid.co.za/index.php/sajid/article/view/244
id doaj-94789ab4c7ea4bbb9d0fe79603a8f147
record_format Article
spelling doaj-94789ab4c7ea4bbb9d0fe79603a8f1472021-04-21T11:59:46ZengAOSISSouthern African Journal of Infectious Diseases2312-00532313-18102021-04-01361e1e910.4102/sajid.v36i1.244180The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemiaHafsah D. Tootla0Colleen Bamford1Chad M. Centner2Clinton Moodley3Division of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa; and, National Health Laboratory Service, Microbiology, Groote Schuur Hospital, Cape TownDivision of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa; and, National Health Laboratory Service, Microbiology, Groote Schuur Hospital, Cape TownDivision of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa; and, National Health Laboratory Service, Microbiology, Groote Schuur Hospital, Cape TownDivision of Medical Microbiology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa; and, National Health Laboratory Service, Microbiology, Groote Schuur Hospital, Cape TownBackground: Culture remains the diagnostic standard for Streptococcus pneumoniae bacteraemia but is limited by time to identification, prior antibiotics and bacterial autolysis. Culture-independent methods for detecting S. pneumoniae include PCR and antigen tests. We evaluated an antigen test on blood culture broth for the rapid detection of S. pneumoniae bacteraemia. Method: We collected 212 signal-positive blood cultures, with gram-positive cocci in pairs, chains or with uncertain morphology. The BinaxNOW S. pneumoniae urinary antigen test, Gram stain, culture and lytA PCR were performed on all samples. Diagnostic accuracy of the antigen test and Gram stain with gram-positive cocci in pairs were compared with culture, polymerase chain reaction (PCR) and the composite of culture and PCR. Results: Streptococcus pneumoniae was isolated in 26% of samples, 66% cultured other gram-positive organisms and 8% of samples had no growth. Sensitivity and negative predictive values of the antigen test were 100%, specificity and positive predictive values were 87% – 88% and 76% – 81%, but increased to 93% – 96% and 96% – 98% when applied to subsets with gram-positive cocci in pairs, or history compatible with respiratory illness or meningitis. Sensitivity (69% – 75%) and specificity (81%) of Gram stain (gram-positive cocci in pairs) were lower than the antigen test even when applied to the same subsets. Conclusion: Accurate and rapid diagnosis of S. pneumoniae bacteraemia is challenging. Specificity of this antigen test is limited by cross-reactivity with other gram-positive organisms, but could be improved if Gram stain morphology and clinical history are available. The antigen test is a useful adjunct for rapid diagnosis of S. pneumoniae bacteraemia.https://sajid.co.za/index.php/sajid/article/view/244streptococcus pneumoniaebacteraemiabinaxnowantigenpneumococcal diagnosistest
collection DOAJ
language English
format Article
sources DOAJ
author Hafsah D. Tootla
Colleen Bamford
Chad M. Centner
Clinton Moodley
spellingShingle Hafsah D. Tootla
Colleen Bamford
Chad M. Centner
Clinton Moodley
The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia
Southern African Journal of Infectious Diseases
streptococcus pneumoniae
bacteraemia
binaxnow
antigen
pneumococcal diagnosis
test
author_facet Hafsah D. Tootla
Colleen Bamford
Chad M. Centner
Clinton Moodley
author_sort Hafsah D. Tootla
title The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia
title_short The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia
title_full The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia
title_fullStr The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia
title_full_unstemmed The BinaxNOW pneumococcal antigen test: An adjunct for diagnosis of pneumococcal bacteraemia
title_sort binaxnow pneumococcal antigen test: an adjunct for diagnosis of pneumococcal bacteraemia
publisher AOSIS
series Southern African Journal of Infectious Diseases
issn 2312-0053
2313-1810
publishDate 2021-04-01
description Background: Culture remains the diagnostic standard for Streptococcus pneumoniae bacteraemia but is limited by time to identification, prior antibiotics and bacterial autolysis. Culture-independent methods for detecting S. pneumoniae include PCR and antigen tests. We evaluated an antigen test on blood culture broth for the rapid detection of S. pneumoniae bacteraemia. Method: We collected 212 signal-positive blood cultures, with gram-positive cocci in pairs, chains or with uncertain morphology. The BinaxNOW S. pneumoniae urinary antigen test, Gram stain, culture and lytA PCR were performed on all samples. Diagnostic accuracy of the antigen test and Gram stain with gram-positive cocci in pairs were compared with culture, polymerase chain reaction (PCR) and the composite of culture and PCR. Results: Streptococcus pneumoniae was isolated in 26% of samples, 66% cultured other gram-positive organisms and 8% of samples had no growth. Sensitivity and negative predictive values of the antigen test were 100%, specificity and positive predictive values were 87% – 88% and 76% – 81%, but increased to 93% – 96% and 96% – 98% when applied to subsets with gram-positive cocci in pairs, or history compatible with respiratory illness or meningitis. Sensitivity (69% – 75%) and specificity (81%) of Gram stain (gram-positive cocci in pairs) were lower than the antigen test even when applied to the same subsets. Conclusion: Accurate and rapid diagnosis of S. pneumoniae bacteraemia is challenging. Specificity of this antigen test is limited by cross-reactivity with other gram-positive organisms, but could be improved if Gram stain morphology and clinical history are available. The antigen test is a useful adjunct for rapid diagnosis of S. pneumoniae bacteraemia.
topic streptococcus pneumoniae
bacteraemia
binaxnow
antigen
pneumococcal diagnosis
test
url https://sajid.co.za/index.php/sajid/article/view/244
work_keys_str_mv AT hafsahdtootla thebinaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT colleenbamford thebinaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT chadmcentner thebinaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT clintonmoodley thebinaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT hafsahdtootla binaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT colleenbamford binaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT chadmcentner binaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
AT clintonmoodley binaxnowpneumococcalantigentestanadjunctfordiagnosisofpneumococcalbacteraemia
_version_ 1721516345838796800