A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source

Shower wastewater contains large amounts of heat, and recovering and utilizing shower wastewater heat energy to heat shower water is of great significance for energy saving. This paper proposed a gas engine heat pump water heater (GEHPWH) using shower wastewater as the heat source. Thermodynamic mod...

Full description

Bibliographic Details
Main Authors: Fengguo Liu, Zhenxi Ma, Rui Zhang
Format: Article
Language:English
Published: IWA Publishing 2019-09-01
Series:Journal of Water Reuse and Desalination
Subjects:
Online Access:http://jwrd.iwaponline.com/content/9/3/310
id doaj-94ba4a600a9d4444b5a22270a16530d1
record_format Article
spelling doaj-94ba4a600a9d4444b5a22270a16530d12020-11-24T22:16:05ZengIWA PublishingJournal of Water Reuse and Desalination2220-13192408-93702019-09-019331031810.2166/wrd.2019.002002A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat sourceFengguo Liu0Zhenxi Ma1Rui Zhang2 School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China and Beijing Advanced Innovation Center for Future Urban Design, Beijing University of Civil Engineering and Architecture, Beijing 100044, China School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China and Beijing Advanced Innovation Center for Future Urban Design, Beijing University of Civil Engineering and Architecture, Beijing 100044, China School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China and Beijing Advanced Innovation Center for Future Urban Design, Beijing University of Civil Engineering and Architecture, Beijing 100044, China Shower wastewater contains large amounts of heat, and recovering and utilizing shower wastewater heat energy to heat shower water is of great significance for energy saving. This paper proposed a gas engine heat pump water heater (GEHPWH) using shower wastewater as the heat source. Thermodynamic models were built to evaluate the performance of the GEHPWH and compare it with an electrical heat pump water heater (EHPWH). The results show that the GEHPWH has higher hot water outlet temperature and coefficient of performance (COP) than the EHPWH under the same conditions. Furthermore, the GEHPWH can maintain stable hot water outlet temperature and higher primary energy ratio (PER) in variable water flow mode, which resolves the issue that the conventional EHPWH needs an auxiliary heat source. Finally, based on a case, the GEHPWH reveals smaller energy consumption and lower operating costs compared with three other conventional hot-water schemes.http://jwrd.iwaponline.com/content/9/3/310gas engine heat pump water heateroptimizationshower wastewater heat recoverythermodynamic
collection DOAJ
language English
format Article
sources DOAJ
author Fengguo Liu
Zhenxi Ma
Rui Zhang
spellingShingle Fengguo Liu
Zhenxi Ma
Rui Zhang
A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
Journal of Water Reuse and Desalination
gas engine heat pump water heater
optimization
shower wastewater heat recovery
thermodynamic
author_facet Fengguo Liu
Zhenxi Ma
Rui Zhang
author_sort Fengguo Liu
title A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
title_short A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
title_full A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
title_fullStr A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
title_full_unstemmed A study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
title_sort study on the design and analysis of a gas engine heat pump water heater using shower wastewater as heat source
publisher IWA Publishing
series Journal of Water Reuse and Desalination
issn 2220-1319
2408-9370
publishDate 2019-09-01
description Shower wastewater contains large amounts of heat, and recovering and utilizing shower wastewater heat energy to heat shower water is of great significance for energy saving. This paper proposed a gas engine heat pump water heater (GEHPWH) using shower wastewater as the heat source. Thermodynamic models were built to evaluate the performance of the GEHPWH and compare it with an electrical heat pump water heater (EHPWH). The results show that the GEHPWH has higher hot water outlet temperature and coefficient of performance (COP) than the EHPWH under the same conditions. Furthermore, the GEHPWH can maintain stable hot water outlet temperature and higher primary energy ratio (PER) in variable water flow mode, which resolves the issue that the conventional EHPWH needs an auxiliary heat source. Finally, based on a case, the GEHPWH reveals smaller energy consumption and lower operating costs compared with three other conventional hot-water schemes.
topic gas engine heat pump water heater
optimization
shower wastewater heat recovery
thermodynamic
url http://jwrd.iwaponline.com/content/9/3/310
work_keys_str_mv AT fengguoliu astudyonthedesignandanalysisofagasengineheatpumpwaterheaterusingshowerwastewaterasheatsource
AT zhenxima astudyonthedesignandanalysisofagasengineheatpumpwaterheaterusingshowerwastewaterasheatsource
AT ruizhang astudyonthedesignandanalysisofagasengineheatpumpwaterheaterusingshowerwastewaterasheatsource
AT fengguoliu studyonthedesignandanalysisofagasengineheatpumpwaterheaterusingshowerwastewaterasheatsource
AT zhenxima studyonthedesignandanalysisofagasengineheatpumpwaterheaterusingshowerwastewaterasheatsource
AT ruizhang studyonthedesignandanalysisofagasengineheatpumpwaterheaterusingshowerwastewaterasheatsource
_version_ 1725791357409165312