Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada

The aim of this study was to evaluate the precision and accuracy of linear measurements of maxillary sinus made in tomographic films, by comparing with 3D reconstructed images. Linear measurements of both maxillary sinus in computed tomography CT of 17 patients, with or without lesion by two calibra...

Full description

Bibliographic Details
Main Authors: Andréia Perella, Sara dos Santos Rocha, Marcelo de Gusmão Paraiso Cavalcanti
Format: Article
Language:English
Published: University of São Paulo 2003-09-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572003000300013
id doaj-959be3f366b24d05927a2f17cdd99562
record_format Article
spelling doaj-959be3f366b24d05927a2f17cdd995622020-11-24T21:38:00ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652003-09-0111322923310.1590/S1678-77572003000300013Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizadaAndréia PerellaSara dos Santos RochaMarcelo de Gusmão Paraiso CavalcantiThe aim of this study was to evaluate the precision and accuracy of linear measurements of maxillary sinus made in tomographic films, by comparing with 3D reconstructed images. Linear measurements of both maxillary sinus in computed tomography CT of 17 patients, with or without lesion by two calibrated examiners independently, on two occasions, with a single manual caliper. A third examiner has done the same measurements electronically in 3D-CT reconstruction. The statistical analysis was performed using ANOVA (analyses of variance). Intra-observer percentage error was little in both cases, with and without lesion; it ranged from 1.14% to 1.82%. The inter-observer error was a little higher reaching a 2.08% value. The accuracy presented a higher value. The perceptual accuracy error was higher in samples, which had lesion compared to that which had not. CT had provided adequate precision and accuracy for maxillary sinus analyses. The precision in cases with lesion was considered inferior when compared to that without lesion, but it can't affect the method efficacy.<br>O objetivo deste trabalho foi avaliar a precisão e acurácia de medidas lineares da região de seio maxilar realizadas em filmes tomográficos, por meio de comparação com a reconstrução da imagem em 3D. Medidas lineares de ambos os seios maxilares foram realizadas em tomografias computadorizadas (2D-TC) de 17 pacientes, normais e com lesão, por dois examinadores, calibrados, separadamente, duas vezes cada um, utilizando um compasso. Um terceiro observador realizou as mesmas medidas eletronicamente na reconstrução 3D-TC. ANOVA (análise de variância) foi utilizado para análise estatística. A porcentagem de erro intra-examinadores foi pequena em ambos os casos, com ou sem lesão, variando de 1,14% a 1,82%. O erro inter-examinadores foi maior alcançando o valor de 2,08% .O erro percentual de acurácia nas amostras com lesão foram maiores comparando-as às que não tinham lesão. A tomografia computadorizada em 2D-TC (Em filmes e estação de trabalho independente) proporcionou precisão e acurácia adequadas para análise dos seios maxilares. "O erro foi maior no caso de seios maxilares com lesão,comparando aos lados sem lesão, tanto inter quanto intra-examinadores, sem alterar, porém, a eficácia do método."http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572003000300013TomografiaRaios x por computadorSeio maxilarEstudo quantitativoTomographyX-ray computedMaxillary sinusQuantitative study
collection DOAJ
language English
format Article
sources DOAJ
author Andréia Perella
Sara dos Santos Rocha
Marcelo de Gusmão Paraiso Cavalcanti
spellingShingle Andréia Perella
Sara dos Santos Rocha
Marcelo de Gusmão Paraiso Cavalcanti
Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada
Journal of Applied Oral Science
Tomografia
Raios x por computador
Seio maxilar
Estudo quantitativo
Tomography
X-ray computed
Maxillary sinus
Quantitative study
author_facet Andréia Perella
Sara dos Santos Rocha
Marcelo de Gusmão Paraiso Cavalcanti
author_sort Andréia Perella
title Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada
title_short Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada
title_full Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada
title_fullStr Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada
title_full_unstemmed Quantitative analyses of maxillary sinus using computed tomography Análise quantitativa dos seios maxilares por meio da tomografia computadorizada
title_sort quantitative analyses of maxillary sinus using computed tomography análise quantitativa dos seios maxilares por meio da tomografia computadorizada
publisher University of São Paulo
series Journal of Applied Oral Science
issn 1678-7757
1678-7765
publishDate 2003-09-01
description The aim of this study was to evaluate the precision and accuracy of linear measurements of maxillary sinus made in tomographic films, by comparing with 3D reconstructed images. Linear measurements of both maxillary sinus in computed tomography CT of 17 patients, with or without lesion by two calibrated examiners independently, on two occasions, with a single manual caliper. A third examiner has done the same measurements electronically in 3D-CT reconstruction. The statistical analysis was performed using ANOVA (analyses of variance). Intra-observer percentage error was little in both cases, with and without lesion; it ranged from 1.14% to 1.82%. The inter-observer error was a little higher reaching a 2.08% value. The accuracy presented a higher value. The perceptual accuracy error was higher in samples, which had lesion compared to that which had not. CT had provided adequate precision and accuracy for maxillary sinus analyses. The precision in cases with lesion was considered inferior when compared to that without lesion, but it can't affect the method efficacy.<br>O objetivo deste trabalho foi avaliar a precisão e acurácia de medidas lineares da região de seio maxilar realizadas em filmes tomográficos, por meio de comparação com a reconstrução da imagem em 3D. Medidas lineares de ambos os seios maxilares foram realizadas em tomografias computadorizadas (2D-TC) de 17 pacientes, normais e com lesão, por dois examinadores, calibrados, separadamente, duas vezes cada um, utilizando um compasso. Um terceiro observador realizou as mesmas medidas eletronicamente na reconstrução 3D-TC. ANOVA (análise de variância) foi utilizado para análise estatística. A porcentagem de erro intra-examinadores foi pequena em ambos os casos, com ou sem lesão, variando de 1,14% a 1,82%. O erro inter-examinadores foi maior alcançando o valor de 2,08% .O erro percentual de acurácia nas amostras com lesão foram maiores comparando-as às que não tinham lesão. A tomografia computadorizada em 2D-TC (Em filmes e estação de trabalho independente) proporcionou precisão e acurácia adequadas para análise dos seios maxilares. "O erro foi maior no caso de seios maxilares com lesão,comparando aos lados sem lesão, tanto inter quanto intra-examinadores, sem alterar, porém, a eficácia do método."
topic Tomografia
Raios x por computador
Seio maxilar
Estudo quantitativo
Tomography
X-ray computed
Maxillary sinus
Quantitative study
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572003000300013
work_keys_str_mv AT andreiaperella quantitativeanalysesofmaxillarysinususingcomputedtomographyanalisequantitativadosseiosmaxilarespormeiodatomografiacomputadorizada
AT saradossantosrocha quantitativeanalysesofmaxillarysinususingcomputedtomographyanalisequantitativadosseiosmaxilarespormeiodatomografiacomputadorizada
AT marcelodegusmaoparaisocavalcanti quantitativeanalysesofmaxillarysinususingcomputedtomographyanalisequantitativadosseiosmaxilarespormeiodatomografiacomputadorizada
_version_ 1725935948249694208