STUDY ON NEUTRON – GAMMA PULSE SHAPE DISCRIMINATION ALGORITHMS FOR SCINTILLATION DETECTOR
The four neutron - gamma pulsed shape discrimination algorithms for the model NE213 scintillation detector by using digital signal processing were developed. In this study, a pulse generator, pulse digitizer and neutron - gamma pulsed shape discrimination algorithms are simulated in Matlab, Simulink...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dalat University
2016-09-01
|
Series: | Tạp chí Khoa học Đại học Đà Lạt |
Subjects: | |
Online Access: | http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/72 |
Summary: | The four neutron - gamma pulsed shape discrimination algorithms for the model NE213 scintillation detector by using digital signal processing were developed. In this study, a pulse generator, pulse digitizer and neutron - gamma pulsed shape discrimination algorithms are simulated in Matlab, Simulink software. The results obtained show that the method to rise-time discrimination has a quality factor (Figure-of-Merits: FOM=1.09), pulsed gradient analysis method (FOM = 0.66), charge comparison method (FOM = 2.21), and correlation pattern method (FOM = 1.97). This result is the basis for building systems for measurements of neutron using scintillation detectors. |
---|---|
ISSN: | 0866-787X 0866-787X |