Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation

AIM:To observe the clinical efficacy of two types of scleral-fixated posterior chamber intraocular lens(IOL)combined intra-capsule lens extraction to treat cataract dislocation.<p>METHODS: After intra-capsule lens extraction of dislocated cataract, two types of IOL were used as scleral-fixated...

Full description

Bibliographic Details
Main Authors: Fang-Zhu Deng, Guo-Ping Kuang
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2014-12-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2014/12/201412025.pdf
id doaj-97766652fc7c46d880799689866dca98
record_format Article
spelling doaj-97766652fc7c46d880799689866dca982020-11-24T23:33:42ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-12-0114122201220310.3980/j.issn.1672-5123.2014.12.25Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocationFang-Zhu Deng0Guo-Ping Kuang1Department of Ophthalmology, the Fourth People's Hospital, Chenzhou 424100, Hunan Province, ChinaDepartment of Ophthalmology, the First People's Hospital, Chenzhou 424100, Hunan Province, ChinaAIM:To observe the clinical efficacy of two types of scleral-fixated posterior chamber intraocular lens(IOL)combined intra-capsule lens extraction to treat cataract dislocation.<p>METHODS: After intra-capsule lens extraction of dislocated cataract, two types of IOL were used as scleral-fixated posterior chamber IOL. First group was with four seal loops, the second group was with two open loops. All 21 patients(23 eyes)took the examination of the best corrected visual acuity, intraocular pressure, fundus, and IOL decentration using camera system attached to slit-lamp ophthalmoscope and IOL tilted using ultrasound biomicroscopy(UBM)at 6mo after surgery. <p>RESULTS: After 6mo, all patients had improved eye sight. There was significant difference in the mean IOL decentration between the two groups(0.57mm <i>vs</i> 0.79mm, <i>P</i><0.05). There was significant difference in the mean IOL tilted degree between the two groups(6° <i>vs</i> 11°, <i>P</i><0.05).<p>CONCLUSION: IOL with four loops are more appropriate as scleral-fixated posterior chamber IOL with less tiltness and dicentration.http://ies.ijo.cn/cn_publish/2014/12/201412025.pdflens implantationlens dislocationfixationlens loopfoldable
collection DOAJ
language English
format Article
sources DOAJ
author Fang-Zhu Deng
Guo-Ping Kuang
spellingShingle Fang-Zhu Deng
Guo-Ping Kuang
Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
Guoji Yanke Zazhi
lens implantation
lens dislocation
fixation
lens loop
foldable
author_facet Fang-Zhu Deng
Guo-Ping Kuang
author_sort Fang-Zhu Deng
title Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
title_short Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
title_full Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
title_fullStr Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
title_full_unstemmed Observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
title_sort observation of two types of foldable scleral-fixated posterior chamber intraocular lens to treat cataract dislocation
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
1672-5123
publishDate 2014-12-01
description AIM:To observe the clinical efficacy of two types of scleral-fixated posterior chamber intraocular lens(IOL)combined intra-capsule lens extraction to treat cataract dislocation.<p>METHODS: After intra-capsule lens extraction of dislocated cataract, two types of IOL were used as scleral-fixated posterior chamber IOL. First group was with four seal loops, the second group was with two open loops. All 21 patients(23 eyes)took the examination of the best corrected visual acuity, intraocular pressure, fundus, and IOL decentration using camera system attached to slit-lamp ophthalmoscope and IOL tilted using ultrasound biomicroscopy(UBM)at 6mo after surgery. <p>RESULTS: After 6mo, all patients had improved eye sight. There was significant difference in the mean IOL decentration between the two groups(0.57mm <i>vs</i> 0.79mm, <i>P</i><0.05). There was significant difference in the mean IOL tilted degree between the two groups(6° <i>vs</i> 11°, <i>P</i><0.05).<p>CONCLUSION: IOL with four loops are more appropriate as scleral-fixated posterior chamber IOL with less tiltness and dicentration.
topic lens implantation
lens dislocation
fixation
lens loop
foldable
url http://ies.ijo.cn/cn_publish/2014/12/201412025.pdf
work_keys_str_mv AT fangzhudeng observationoftwotypesoffoldablescleralfixatedposteriorchamberintraocularlenstotreatcataractdislocation
AT guopingkuang observationoftwotypesoffoldablescleralfixatedposteriorchamberintraocularlenstotreatcataractdislocation
_version_ 1725531179634917376