METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY

The design of special verification phantom for dynamic radiotherapy checking is described. This phantom permits to insert the dose distribution cross-calibration before every days patients irradiation on Linac with RapidArc. Cross-calibration factor is defined by approximation of large number correc...

Full description

Bibliographic Details
Main Authors: Y. V. Tsitovich, A. I. Hmyrak, A. I. Tarutin, M. G. Kiselev
Format: Article
Language:English
Published: Belarusian National Technical University 2015-03-01
Series:Pribory i Metody Izmerenij
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/24
id doaj-983677050b00438893d6401069a08f6b
record_format Article
spelling doaj-983677050b00438893d6401069a08f6b2021-07-29T08:39:07ZengBelarusian National Technical UniversityPribory i Metody Izmerenij2220-95062414-04732015-03-01019710218METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPYY. V. Tsitovich0A. I. Hmyrak1A. I. Tarutin2M. G. Kiselev3РНПЦ онкологии и медицинской радиологии им. Н.Н. Александрова, г. МинскРНПЦ онкологии и медицинской радиологии им. Н.Н. Александрова, г. МинскРНПЦ онкологии и медицинской радиологии им. Н.Н. Александрова, г. МинскБелорусский национальный технический университетThe design of special verification phantom for dynamic radiotherapy checking is described. This phantom permits to insert the dose distribution cross-calibration before every days patients irradiation on Linac with RapidArc. Cross-calibration factor is defined by approximation of large number correction factors measured in phantom at different angles of gantry rotation and middle quantity calculation. The long range stability of all correction factors have been evaluated during checking of setting treatment plans and did not exceed 1 %. The fast checking of patient’s dynamic irradiation with developed method gives possibility texactly realize of planning dose distribution and to increase the capacity of accelerators.https://pimi.bntu.by/jour/article/view/24rapidarcdose output verificationcross-calibration of complex dose fluencesverification phantom construction
collection DOAJ
language English
format Article
sources DOAJ
author Y. V. Tsitovich
A. I. Hmyrak
A. I. Tarutin
M. G. Kiselev
spellingShingle Y. V. Tsitovich
A. I. Hmyrak
A. I. Tarutin
M. G. Kiselev
METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY
Pribory i Metody Izmerenij
rapidarc
dose output verification
cross-calibration of complex dose fluences
verification phantom construction
author_facet Y. V. Tsitovich
A. I. Hmyrak
A. I. Tarutin
M. G. Kiselev
author_sort Y. V. Tsitovich
title METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY
title_short METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY
title_full METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY
title_fullStr METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY
title_full_unstemmed METHODS AND HARDWARE OF DOSE OUTPUT VERIFICATION FOR DYNAMIC RADIOTHERAPY
title_sort methods and hardware of dose output verification for dynamic radiotherapy
publisher Belarusian National Technical University
series Pribory i Metody Izmerenij
issn 2220-9506
2414-0473
publishDate 2015-03-01
description The design of special verification phantom for dynamic radiotherapy checking is described. This phantom permits to insert the dose distribution cross-calibration before every days patients irradiation on Linac with RapidArc. Cross-calibration factor is defined by approximation of large number correction factors measured in phantom at different angles of gantry rotation and middle quantity calculation. The long range stability of all correction factors have been evaluated during checking of setting treatment plans and did not exceed 1 %. The fast checking of patient’s dynamic irradiation with developed method gives possibility texactly realize of planning dose distribution and to increase the capacity of accelerators.
topic rapidarc
dose output verification
cross-calibration of complex dose fluences
verification phantom construction
url https://pimi.bntu.by/jour/article/view/24
work_keys_str_mv AT yvtsitovich methodsandhardwareofdoseoutputverificationfordynamicradiotherapy
AT aihmyrak methodsandhardwareofdoseoutputverificationfordynamicradiotherapy
AT aitarutin methodsandhardwareofdoseoutputverificationfordynamicradiotherapy
AT mgkiselev methodsandhardwareofdoseoutputverificationfordynamicradiotherapy
_version_ 1721253021125443584