Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose dis...

Full description

Bibliographic Details
Main Authors: Micaeil Mollazadeh, Mahmood Allahverdi, Tayyeb Allahverdi Pourfallah, Nader Riahi Alam, Mohammadreza Ay
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2010-06-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:http://ijmp.mums.ac.ir/article_7264_1da6f8a35b4d3b0c568fd5c9c4d53f71.pdf
id doaj-994652c5ebcc4f9aa754acece0e486a3
record_format Article
spelling doaj-994652c5ebcc4f9aa754acece0e486a32020-11-24T22:36:27ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722010-06-0172819310.22038/ijmp.2010.72647264Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo SimulationMicaeil Mollazadeh0Mahmood Allahverdi1Tayyeb Allahverdi Pourfallah2Nader Riahi Alam3Mohammadreza Ay4M.Sc. student in Medical Physics, Medical Physics and Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran.Associate Professor, Medical Physics and Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran.Assistant Professor, Biochemistry and Biophysics Dept., Mazandaran University of Medical Sciences, Sari, Iran.Associate Professor, Medical Physics and Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran.Associate Professor, Medical Physics and Engineering Dept., Tehran University of Medical Sciences, Tehran, Iran.Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of the RtDosePlan TPS such as PDD curves, lateral beam profiles, and isodose curves measured in a water phantom using EBT Radiochromic film and EGSnrc Monte Carlo (MC) simulation. Methods and Materials: A Microtek color scanner was used as the film scanning system, where the response in the red color channel was extracted and used for the analyses. A calibration curve was measured using pieces of irradiated films to specific doses. The film was mounted inside the phantom parallel to the beam's central axis and was irradiated in a standard setup (SSD = 80 cm, FS = 10×10 cm2) with a 60Co machine. The BEAMnrc and the DOSXYZnrc codes were used to simulate the Co-60 machine and extracting the voxel-based phantom. The phantom's acquired CT data were transferred to the TPS using DICOM files. Results: Distance-To-Agreement (DTA) and Dose Difference (DD) among the TPS predictions, measurements and MC calculations were all within the acceptance criteria (DD=3%, DTA=3 mm). Conclusion: This study shows that EBT film is an appropriate tool for verification of 2D dose distribution predicted by a TPS system. In addition, it is concluded that MC simulation with the BEAMnrc code has a suitable potential for verifying dose distributions.http://ijmp.mums.ac.ir/article_7264_1da6f8a35b4d3b0c568fd5c9c4d53f71.pdfDose Distribution, Flatbed Scanner, Monte Carlo, Radiochromic Film Dosimetry,TPS Verification
collection DOAJ
language English
format Article
sources DOAJ
author Micaeil Mollazadeh
Mahmood Allahverdi
Tayyeb Allahverdi Pourfallah
Nader Riahi Alam
Mohammadreza Ay
spellingShingle Micaeil Mollazadeh
Mahmood Allahverdi
Tayyeb Allahverdi Pourfallah
Nader Riahi Alam
Mohammadreza Ay
Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
Iranian Journal of Medical Physics
Dose Distribution, Flatbed Scanner, Monte Carlo, Radiochromic Film Dosimetry,
TPS Verification
author_facet Micaeil Mollazadeh
Mahmood Allahverdi
Tayyeb Allahverdi Pourfallah
Nader Riahi Alam
Mohammadreza Ay
author_sort Micaeil Mollazadeh
title Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
title_short Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
title_full Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
title_fullStr Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
title_full_unstemmed Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
title_sort evaluation of the rtdoseplan treatment planning system using radiochromic film and monte carlo simulation
publisher Mashhad University of Medical Sciences
series Iranian Journal of Medical Physics
issn 2345-3672
2345-3672
publishDate 2010-06-01
description Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of the RtDosePlan TPS such as PDD curves, lateral beam profiles, and isodose curves measured in a water phantom using EBT Radiochromic film and EGSnrc Monte Carlo (MC) simulation. Methods and Materials: A Microtek color scanner was used as the film scanning system, where the response in the red color channel was extracted and used for the analyses. A calibration curve was measured using pieces of irradiated films to specific doses. The film was mounted inside the phantom parallel to the beam's central axis and was irradiated in a standard setup (SSD = 80 cm, FS = 10×10 cm2) with a 60Co machine. The BEAMnrc and the DOSXYZnrc codes were used to simulate the Co-60 machine and extracting the voxel-based phantom. The phantom's acquired CT data were transferred to the TPS using DICOM files. Results: Distance-To-Agreement (DTA) and Dose Difference (DD) among the TPS predictions, measurements and MC calculations were all within the acceptance criteria (DD=3%, DTA=3 mm). Conclusion: This study shows that EBT film is an appropriate tool for verification of 2D dose distribution predicted by a TPS system. In addition, it is concluded that MC simulation with the BEAMnrc code has a suitable potential for verifying dose distributions.
topic Dose Distribution, Flatbed Scanner, Monte Carlo, Radiochromic Film Dosimetry,
TPS Verification
url http://ijmp.mums.ac.ir/article_7264_1da6f8a35b4d3b0c568fd5c9c4d53f71.pdf
work_keys_str_mv AT micaeilmollazadeh evaluationofthertdoseplantreatmentplanningsystemusingradiochromicfilmandmontecarlosimulation
AT mahmoodallahverdi evaluationofthertdoseplantreatmentplanningsystemusingradiochromicfilmandmontecarlosimulation
AT tayyeballahverdipourfallah evaluationofthertdoseplantreatmentplanningsystemusingradiochromicfilmandmontecarlosimulation
AT naderriahialam evaluationofthertdoseplantreatmentplanningsystemusingradiochromicfilmandmontecarlosimulation
AT mohammadrezaay evaluationofthertdoseplantreatmentplanningsystemusingradiochromicfilmandmontecarlosimulation
_version_ 1725720260372332544