Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts

Objectives: To prospectively evaluate the performance of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry systems (MALDI-TOF MS) for the identification of clinically significant yeast isolates compared to the VITEK 2 system. Methods: One hundred and eighty-eight cons...

Full description

Bibliographic Details
Main Authors: W.Y. Jamal, S. Ahmad, Z.U. Khan, V.O. Rotimi
Format: Article
Language:English
Published: Elsevier 2014-09-01
Series:International Journal of Infectious Diseases
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1201971214015604
id doaj-99e0617aeca04b7f925238781fcd85d3
record_format Article
spelling doaj-99e0617aeca04b7f925238781fcd85d32020-11-25T00:59:58ZengElsevierInternational Journal of Infectious Diseases1201-97121878-35112014-09-0126C16717010.1016/j.ijid.2014.05.031Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeastsW.Y. Jamal0S. Ahmad1Z.U. Khan2V.O. Rotimi3Department of Microbiology, Faculty of Medicine, Kuwait University, PO Box 24923, Safat 13110, KuwaitDepartment of Microbiology, Faculty of Medicine, Kuwait University, PO Box 24923, Safat 13110, KuwaitDepartment of Microbiology, Faculty of Medicine, Kuwait University, PO Box 24923, Safat 13110, KuwaitDepartment of Microbiology, Faculty of Medicine, Kuwait University, PO Box 24923, Safat 13110, Kuwait Objectives: To prospectively evaluate the performance of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry systems (MALDI-TOF MS) for the identification of clinically significant yeast isolates compared to the VITEK 2 system. Methods: One hundred and eighty-eight consecutive yeast isolates were analyzed by Bruker Biotyper and VITEK MS. The results were compared with the conventional VITEK 2 yeast identification system. Discrepant results were resolved by direct sequencing of rDNA. Results: Accurate identification by VITEK 2, VITEK MS, and Bruker Biotyper MS was 94.1% (177/188), 93.0% (175/188), and 92.6% (174/188), respectively. Three isolates were not identified by VITEK MS, while nine Candida orthopsilosis were misidentified as Candida parapsilosis, as this species is not present in its database. Eleven isolates were not identified or were wrongly identified by Bruker Biotyper and although another 14 were correctly identified, the score was unreliable at <1.7. Conclusion: The overall accuracy of rapid MALDI-TOF MS systems was essentially comparable to that of the conventional VITEK 2 yeast identification system. However, future expansion of the databases may further improve the outcome and accuracy of identification of yeast species. http://www.sciencedirect.com/science/article/pii/S1201971214015604MALDI-TOF MSYeastsIdentificationVITEK 2 system
collection DOAJ
language English
format Article
sources DOAJ
author W.Y. Jamal
S. Ahmad
Z.U. Khan
V.O. Rotimi
spellingShingle W.Y. Jamal
S. Ahmad
Z.U. Khan
V.O. Rotimi
Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts
International Journal of Infectious Diseases
MALDI-TOF MS
Yeasts
Identification
VITEK 2 system
author_facet W.Y. Jamal
S. Ahmad
Z.U. Khan
V.O. Rotimi
author_sort W.Y. Jamal
title Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts
title_short Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts
title_full Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts
title_fullStr Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts
title_full_unstemmed Comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems for the identification of clinically significant yeasts
title_sort comparative evaluation of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (maldi-tof ms) systems for the identification of clinically significant yeasts
publisher Elsevier
series International Journal of Infectious Diseases
issn 1201-9712
1878-3511
publishDate 2014-09-01
description Objectives: To prospectively evaluate the performance of two matrix-assisted laser desorption/ionization time-of-flight mass spectrometry systems (MALDI-TOF MS) for the identification of clinically significant yeast isolates compared to the VITEK 2 system. Methods: One hundred and eighty-eight consecutive yeast isolates were analyzed by Bruker Biotyper and VITEK MS. The results were compared with the conventional VITEK 2 yeast identification system. Discrepant results were resolved by direct sequencing of rDNA. Results: Accurate identification by VITEK 2, VITEK MS, and Bruker Biotyper MS was 94.1% (177/188), 93.0% (175/188), and 92.6% (174/188), respectively. Three isolates were not identified by VITEK MS, while nine Candida orthopsilosis were misidentified as Candida parapsilosis, as this species is not present in its database. Eleven isolates were not identified or were wrongly identified by Bruker Biotyper and although another 14 were correctly identified, the score was unreliable at <1.7. Conclusion: The overall accuracy of rapid MALDI-TOF MS systems was essentially comparable to that of the conventional VITEK 2 yeast identification system. However, future expansion of the databases may further improve the outcome and accuracy of identification of yeast species.
topic MALDI-TOF MS
Yeasts
Identification
VITEK 2 system
url http://www.sciencedirect.com/science/article/pii/S1201971214015604
work_keys_str_mv AT wyjamal comparativeevaluationoftwomatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrymalditofmssystemsfortheidentificationofclinicallysignificantyeasts
AT sahmad comparativeevaluationoftwomatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrymalditofmssystemsfortheidentificationofclinicallysignificantyeasts
AT zukhan comparativeevaluationoftwomatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrymalditofmssystemsfortheidentificationofclinicallysignificantyeasts
AT vorotimi comparativeevaluationoftwomatrixassistedlaserdesorptionionizationtimeofflightmassspectrometrymalditofmssystemsfortheidentificationofclinicallysignificantyeasts
_version_ 1725215093712486400